|
| 1 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. (DSR 2.27) |
| 2 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 3 | Sal wood (DSR 9.1.2) |
| 4 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. |
| 5 | Kiln seasoned and chemically treated hollock wood |
| 6 | 35 mm thick (DSR 9.9.2.1) |
| 7 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : |
| 8 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. (DSR 9.21.1) |
| 9 | Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). (DSR 9.26) |
| 10 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : |
| 11 | 35 mm thick shutters |
| 12 | with ISI marked M.S. pressed butt hinges bright finished of required size |
| 13 | Kiln seasoned and chemically treated hollock wood (DSR 9.27.1.1.2) |
| 14 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 15 | 300x16 mm (DSR 9.96.1) |
| 16 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 17 | 200x10 mm (DSR 9.97.3) |
| 18 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 19 | 125 mm (DSR 9.100.1) |
| 20 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 21 | Twin rubber stopper (DSR 9.101.2) |
| 22 | Providing and fixing, in position concealed G.l. section for wall paneling using board of required thickness fixed on the W profile (0.55 mm thick) having a knurled web of 51.55 mm and two flanges of 26 mm each with lips of 10.55 mm, placed @610 mm C/C in perimeter channel having one flange of 20 mm and another flange of 30 mm with thickness of 0.55 mm and web of length 27 mm. Perimeter channel is fixed on the floor and the ceiling with the nylon sleeves @610 mm C/C with fully threaded self-tapping dry wall screws. Board is fixed to the ‘W’ profile with 25 mm countersunk ribbed head screws @ 200 mm C/C., all complete as per the drawing & directions of engineer-in-charge, the joints of the boards are finished with specially formulated jointing compound and 48 mm wide jointing tape to provide seamless finish. |
| 23 | Plain Gypsum plaster board conforming to IS: 2095 Part-1:2011 (Board with BIS certification marks) |
| 24 | 12.5 mm thick (DSR 9.133.3.1) |
| 25 | 25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with : |
| 26 | Second class teak wood (DSR 11.33.1) |
| 27 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1 :3 (1 cement : 3 fine sand) as per standard design : |
| 28 | In 75x75 mm deep chase (DSR 12.21.1) |
| 29 | 6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. (DSR 13.17) |
| 30 | Applying priming coat: |
| 31 | With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood (DSR 13.50.2) |
| 32 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 33 | Two or more coats on new work (DSR 13.61.1) |
| 34 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. |
| 35 | One coat (DSR 13.83.1) |
| 36 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. (DSR 13.91) |
| 37 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 38 | One or more coats on old work (DSR 13.99.1) |
| 39 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade |
| 40 | Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface (DSR 13.112.1) |
| 41 | Varnishing with varnish of approved brand and manufacture: |
| 42 | One or more coats with spar varnish (DSR 13.113.2) |
| 43 | Renewing glass panes, with wooden fillets wherever necessary: |
| 44 | Float glass panes of nominal thickness 4 mm (weight not less than10kg/sqm) (DSR 14.6.1) |
| 45 | Regrading terracing of mud phaska covered with tiles or brick, in cement mortar by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud phaska to proper slope, relaying mud plaster gobri leaping and tiles or bricks, grouted in cement mortar 1:3 (1 cement : 3 fine sand), including replacing unserviceable tiles or bricks with new ones and disposal of unserviceable material to the dumping ground (the cost of the new tiles or brick excluded), all complete as per direction of Engineer-in-Charge. (DSR 14.13) |
| 46 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 47 | Of area 3 sq. metres and below (W. Bath) (DSR 15.12.1) |
| 48 | Of area beyond 3 sq. metres (W. T) (DSR 15.12.2) |
| 49 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (DSR 15.56) |
| 50 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer- in-charge. (DSR 15.57) |
| 51 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (DSR 15.60) |
| 52 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225:1987,Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 15x32 mm of length 3000 mm,cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 53 | With semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles. (DSR 26.26.1) |
| 54 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer- In-charge complete in all respect. |
| 55 | SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer (DSR 26.31.1) |
| 56 | Removing of existing Vinyl flooring from the surface of concrete flooring and make the floor for reuse including disposal of malba/rubbish to dumping ground within 50 meters lead complete in all respect to the entire satisfaction of Engineer-in-charge (NS) |
| 57 | Providing and laying PVC (Polyvinyl chloride) flooring of 2 mm thickness on concrete floors as per manufacturer specifications and as per IS: 5318-1969 (code of practice for laying flexible PVC sheet). The rate further include the cost of making the floor free from \\"dust, grease, wax, paint & other deleterious materials\\", drying of floor, using latex self levelling rapid drying deep-fill compound to fill smaller uneven spots of more than 3 mm, floor adhesive etc. complete in all respect as per direction and to the entire satisfaction of the Engineer-in-Charge. (NS) |
| 58 | Providing and applying white cement based putty of average thickness 0.50 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (NS) |
| 59 | Removing of existing tarfelt/ MAK polyplast from the surface of brick tile/tile terracing and make the tile for reuse including disposal of malba/rubbish to dumping ground within 50 meters lead complete in all respect to the entire satisfaction of Engineer-in-charge (NS) |
| 60 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. up to the height of 15m with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge. 25 mm average thickness. (NS) |
| 61 | Dashing cement concrete with 1:1.5:3 (1cement:1.5 coarse sand :3 graded stone aggregates 15mm nominal size) in RCC beams, walls, columns, slabs, chajjas, facia etc. of average thickness 50mm of upto 10m height including the cost of curing and scaffolding etc. complete in all respect and to the entire satisfaction of engineer in charge.(excluding the cost of centering, shuttering, reinforcement) (NS) |
| 62 | Removing rust from exposed reinforcement bars up to 15m height in R.C.C. walls, columns, beams, shelves etc. to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. (NS) |
| 63 | Providing and Fixing chicken mesh of size ½\\"x½\\" and 26 gauge up to 15m height on RCC beams, facias, brick work etc. wherever required with wooden gutties, nails and screws including drilling holes etc complete as per directions of the Engineer-in-charge. (NS) |
| 64 | Dismantling wooden boardings in lining of walls and floor, excluding supporting members but including stacking within 50 metres lead : (Thickness above 10 mm up to 25 mm) Based On (15.39.2) (NS) |
| 65 | Providing & fixing wood work in frames of floor and wall etc. sawn and fixed in position with necessary stainless steel screws etc. Kiln seasoned and chemically treated hollock wood (Based on 9.3.2) (NS) |
| 66 | Providing and fixing12 mm thick Pre -laminated (both side) High Density High Moisture Resistance Board (Grade-I HDHMR) IS:14587:1998 marked, to frame, backing or studding with screws etc. complete ( Frames, backing or studding to be paid separately). (Based on 9.156.1) (NS) |
| 67 | Providing and applying UV resistant fibre glass reinforced PVC membrane of G 410-12L 1.2mm thick or it 's equivalent to Density 1.28 g/cm³, Tensile Strength 9.0 N/mm², Elongation strength 230%, Low temperature bending -20°C. Water vapour permeability 0.04 mg/m²hPa, Vapour diffusion Tesistance factor(μ) 15000, Linear thermal expansion coefficient 0.000016. The PVC membrane should be fully adhered with roof surface using, it 's equivalent, overlapping of 100mm at joints by seam welding and detailing as per the shape of roof surface it should be in rolls of 2x20 m and ude U bar termination along perimeter, termination bar along wall junctions. The rate further includes the cost of electricity, T&P, U-bar, termination-bar, PVC cord etc. complete. The product shall be a holders certificate for of life expactancy of 30 years and guarantee for 10 years complete in all respect and to the entire satisfaction of the Engineer-in-charge. (NS) |
| 68 | WOODEN GROOVED ACOUSTICAL SLATS:- Providing and fixing wood Based panels with lineal perforations of approved make as approved by Engineeer-in-Charge. The panels shall be Non FR grade with melamine laminate panels 2440mm x 128mm x15mm with 2mm slats at 15 mm pitch, Toungue and Groove edges for seamless mounting. The back of the panels fixed wtih acoustical fleece for Sound Absorption. Panel is to be fixed on Dexune framework with screw fixed horizontal or vertical to wall at every 600mm with centre & edge bracket in tongue & groove system on framework. The cavity of framework should be inserted with rock wool with 48 kg density and 25mm thickness and alongwith all accessories complete in all respect and to the entire satisfaction of Engineer in charge. No extra payment for Scaffolding of any other material. (NS) |
| 69 | Providing and fixing Ist quality Planks 200 mm x 1200 mm wall tiles (thickness to be specified by the manufacturer), having linear 3mm wide grooves of approved make and shades as approved by Engineer-in-Charge in skirting and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including filling of groove and pointing with epoxy of matching shade complete in all respect to the entire satisfaction of Engineer-in-Charge. (NS) Please Enable Macros to View BoQ information |