| 1 | Carriage of following material of estimate, from Electricity store center, Hapur to site of work with loading, unloading multiple handling, staking,labour,T&P and transpotation at both ends on Kachha/Packka road, as per direction of site incharge from JE Store/Store center Hapur/Ghaziabad/Bulandshar (0-50 Km) complete in all respects. |
| 2 | 33 KV PT |
| 3 | 33 KV Lightning Arrester |
| 4 | Battery Set |
| 5 | Battery Charger |
| 6 | 33 KV CT |
| 7 | 33 KV Control Panel Single T/F |
| 8 | 33 KV Isolator |
| 9 | 33 KV Fuse Set |
| 10 | LT XLPE Cable 1x240 sqmm |
| 11 | 33 KV Control Panel Double T/F |
| 12 | Earth Rod 2540x20mm |
| 13 | Eraction and fixing and making connection of following material (as per RESPO Norms) at diffrent 33/11 KV substation were include making alignment, all required nut bolt, clamps, Lug, connector, wire and strip etc all labour,T&P, safe & Porper oprations Provided by contractor in all respects. |
| 14 | 33 KV PT |
| 15 | 33 KV Lightning Arrester |
| 16 | Battery Set |
| 17 | Battery Charger |
| 18 | 33 KV CT |
| 19 | 33 KV Control Panel Single T/F |
| 20 | 33 KV Isolator |
| 21 | 33 KV Fuse Set |
| 22 | LT XLPE Cable 1x240 sqmm |
| 23 | 33 KV Control Panel Double T/F |
| 24 | Providing and fixing 11 KV Relay, with (E/F & O/C) of C&S, Ashide, ABB make with 1&5 Amp Port Suitable for 11 kv feeder Pannel as per RESPO/Norms and as per direction of site incharge. all required nut bolt, clamps, Lug, connector etc for safe & Porper oprations Provided by contractor with all labour, T&P in all respects. |
| 25 | Providing and fixing of WTI Meter ISI Mark for 33/11 KV Power Transformer work including making connection proper opration of WTI , as per RESPO/Norms and as per direction of site incharge. All labour, T&P will be provided by contractor in all respects. |
| 26 | Providing and fixing of OTI Meter ISI Mark for 33/11 KV Power Transformer work including making connection proper opration of WTI, as per RESPO/Norms and as per direction of site incharge. All labour, T&P will be provided by contractor in all respects. |
| 27 | Providing and installation of maintenance free multifaceted proactive and corrosion free chemical earthing ( Resistance less than or equal to 2 Omhs) electrod size 80mm x 3000mm complete with 50KG backfill compound with all required accessories for Body/neutral earthing of DT Transformers, including cost of M.S. earth strip for connection the earth strip (50mm x 6mm) will be welded to the earthing and neutral support with lug and nut bolt, as per RESPO/Norms and as per direction of site incharge. all required nut bolt, clamps, Lug, connector etc for safe & Porper oprations Provided by contractor. All labour, T&P will be provided by contractor in all respects. |
| 28 | Providing the material and execution GI pipe earthing with 40 mm dia B class GI Pipe 80 feet boar to water level for proper earthing ( Earthing Resistance less than or equal to 1 Omh ) at 33/11 KV substation with the help of 50mm x 6mm GI Strip duly welding to DT transformer other equipment. With earthing mess lug, nut and bolt. all required nut bolt, clamps, Lug, connector etc for safe & Porper oprations Provided by contractor. All labour, T&P will be provided by contractor in all respects. |
| 29 | Supply and laying ISI Make following Copper Control Cable with make connection from control pannel to Power Transformer Instruments All labour, T&P will be provided by contractor in all respects. |
| 30 | 4x25 sq.mm. |
| 31 | 6x25 sq.mm. |
| 32 | Laying of LT 1x240 Sq.mm. PVC cable as per RESPO/Norms and as per direction of site incharge. All labour, T&P will be provided by contractor in all respects. |
| 33 | Providing and fixing of fire exitinguisher (9kg), as per direction of site incharge. |
| 34 | CO2 Type |
| 35 | ABC Type |
| 36 | Providing and fixing of 33 KV T/F control Panal Relay, as per RESPO/Norms and as per direction of site incharge. (Make C&S, Ashide, ABB) All labour, T&P will be provided by contractor in all respects. |
| 37 | Earthing of 102 Nos 11 KV LA Sets on DT's supports with MS earth Rod of (20x2500)mm long including excavation of pit and driving M.S. Rod 3.0 M apart from support and 0.5m below the ground level and connection below the earth electrodes with the help of 25mm x 3mm GI Strip & earthing lugs as per RESPO Drawing/Norms by providing proper size nuts & bolts and required 25mm x 3mm GI Strip as per direction of site incharge. All labour, T&P will be provided by contractor in all respects. |
| 38 | Providing and fixing of Vaccume Interupter in 11 KV Pannel, as per direction of site incharge. All required nut bolt, clamps, Lug, connector etc for safe & Porper oprations Provided by contractor All labour, T&P will be provided by contractor in all respects. |
| 39 | Providing and Fixing of 11 KV Lighting Arrester with 11/0.4 KV DT and make connection (25mm x 3mm GI Strip will uniform fixing of Lighting Arrester with transformer) All labour, T&P will be provided by contractor in all respects. |
| 40 | Saftly dismantling work properly and carriage of Electircal Equipment from site of work to Electricity store center, Hapur with loading ,unloading , handling and stacking, labour,T&P and transpotation at both ends on Kachha/Packka road, as per direction of site incharge from JE Store/Store center Hapur/Ghaziabad/Bulandshar (0-50 Km) complete in all respects. at both ends on Kachha Packka road, as per direction of site incharge. Please Enable Macros to View BoQ information |