Name of Work:- Road Safety Work of Baberu Tindwari Sumerpur road km 64.020 to km 80.270 (SH-134).
Sl. No.
Item Description
1
Providing and laying of hot thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC-35-2015 the finished surface to be level uniform and free sleek and holes. (Edge line, Centre Line and Zebra Crossing)
2
Providing and laying of hot thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC-35-2015 the finished surface to be level uniform and free sleek and holes. (Repeated / Transverse bar in Abadi)
3
Direction and place identification more than 0.90 Sqm Size board.Providing and erecting direction and place identification retro - reflectorised sign as per IRC 67 made of high intensity grade sheeting . The retro reflective sheeting type-IV shall be tested for 3 year outdoor weathering test in indian condition as per IRC 67:2012 & proof of the same in form of govermnent report shall be uploaded while quoting tender vide clause 801.3 fixed over aluminium sheeting 2mm thick with area exceeding 0.9 sqm . Supported on mild steel single angle iron post 75*75*6mm firmly fixed to the ground by means of properly designed foundation with M-15 grade concrete 45*45*60 cm below ground level as per approved drawing complete.
4
6 M Span over Head Cantilever Structure with 300 dia M S one vertical post Supply, fixing & erection of built up Cantilever Structure of 6m span comprising of one vertical posts of 6.00 m height made up to 300 mm NB heavy class MS pipe as vertical member welded with 10 mm MS plate at top & 12 mm M S plate at bottom. The horizontal truss shall comprise of 50 mm dia heavy class M. S. pipe and 40 mm dia heavy M S pipe as bracing & 10 mm MS plate at bottom for fixing to vertical post as per structure design & drawing with one of steel primer and two coats of synthetic enamel plant. The work includes construction of RCC Foundation of size 0.90x0.90x1.50 m of required depth as per site condition for built up structure including Earth work in excavation 100 mm thick lean concrete 1:3:6 (Cement coarse sand and 40 mm gauge stone ballast and RCC M-25 grade cement concrete including supply and fixing of 25 mm dia Foundation Bolts 600 mm long as per provision of structure design including cost of reinforcement & shuttering. The lateral vertical clearances and complete. Installation work shall be as per relevant clauses of MORT&H specification section 800 and IRC 67 2012 complete in all respect. The rates shall include cost of design, fabrication, supply, transportations, local, shifting Erection of Signage structure using crane, inclusive of all taxes etc. all T&P machine, material and labour required for proper completion of work as per direction of Engineer-in-charge.
5
Retro Reflective Sheetingtype -IV with 4 mm thick ACM Single SideProviding and fixingof reflective signs with a corrisions ressistant 4 mm thick with 0.4 mm to 0.5 mm both sidealuminium skin Aluminium composite pannel…etc as per lucknow circle SI no.10 Morth-801
6
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 mad of high intensity grade sheeting vide clause 801.3, fixed cover aluminium shting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x75 mm x6 mm firmly fixed to th ground by means of properly dsignd foundation with M-15 grade cment conc. 45 cm x 45 cm x 60 cm, 60 cm below ground lvel as per approved drawing (90 cm Equilateral triangle with defination plate)
7
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 mad of high intensity grade sheeting vide clause 801.3, fixed cover aluminium shting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x75 mm x6 mm firmly fixed to th ground by means of properly dsignd foundation with M-15 grade cment conc. 45 cm x 45 cm x 60 cm, 60 cm below ground lvel as per approved drawingHAZARD MARKER (LEFT & Right) Please Enable Macros to View BoQ information
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.