| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. (D.S.R 2.8.1) |
| 2 | Providin of Laying in position cement concrete of specified grade 1:4:8 (1 Cement 4 coarse sand (zone-III) derived. from natural sources graded stone aggregate 40 mm nominal size derived from natural sources) (DS.R 4 1.8) |
| 3 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement All work up to plinth level 1:15:3 (1 cement 15 coarse sand (zone 3 graded stone III) derived from natural sources aggregate 20 mm nominal size derived from natural sources) (D S.R 5.1.2 |
| 4 | Same as above in item No 3 but for beam, roofs, lintel band & etc above plinth level. 1:15:3 (1 cement 1.5 coarse sand (zone-III) derived from natural sources 3 graded stone aggregate 20 mm nominal size derived from natural sources) (D.SR.5.3 |
| 5 | Same as above in item No 4 but for Column as per 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DS.R.5.2.2 |
| 6 | Steel Reinforcement for R.C.C work including cutting,straightening bending binding and placing in position & including complete. Thermo-Mechanically Treated bars of grade Fe-500D or more. (D.S.R.5.22.6 |
| 7 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in 6 coarse sand) Cement mortar 1:6 (1 cement (DSR.6 1.2 |
| 8 | Same as above in item No 7 but in super structure for wall of one brick thickness Brick work with common burnt clayl FPS (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1.6 (1 cement: B coarse sand) (D.SR.6.4) |
| 9 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand. As Per DSR 6.4.1 |
| 10 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete (D.S.R.10.25.1) |
| 11 | Same as item no 10 above but for Fabrication of grill. |
| 12 | Providing and fixing ISI marked flush door shutters conforming to IS 2202 (Part 1) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 35 mm thick including ISi marked Stainless Steel butt hinges with necessary screws (D.S.R.9.21.1) |
| 13 | 12 mm thick plaster with 1.6 cement and coarse sand morter on brick work including ranking and joint washing and cleaning and including supply of all materials labour and T&P etc. required for proper completion of work. (DSR 13.4.2) |
| 14 | Same as above in item No 13 but for plaster on rough facel (DSR 13 5.2) |
| 15 | 25 mm thick 1:2:4 cement conc. Flooring with cement approved coarse sand 2 cm graded approved stone ballast laid in planels finished with 3mm floating coat of neat cement or marbale dust in ratio of 5:1 as specific over and iremoving any overlapping mortar at the joints of the panels if any giving them ao all materials, labour T&P etc. required for the proper completion of work As per S.l.No 601A |
| 16 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc.. complete. Size of Tile 600x600 mm As per D.S.R 11 41.2) |
| 17 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 Itr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (D.S.R. 13.47.1) |
| 18 | Finishing with Deluxe Multi Surface Paint for interiarior or exterior using primer as per manufactures specification. Painting wood work with deluxe multi Multi Surface Paint required shade to or more coat applied @ 0.90 Itr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture (D.S.R.13.48.2) |
| 19 | Earth work by mechinical / manual means in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and for all lift :All kinds of soil(D.S.R.2.2.1) |
| 20 | Supplying and filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. (D.S.R.2.27) |
| 21 | Electrification work |
| 22 | Wiring for light point/ fan point/ exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper onductor single core cablein surface recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. DSR NO. 1.10 |
| 23 | Group C DSR NO. 1.10.3 |
| 24 | Wiring for light/ power plug with 2X4 sq mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper |
| 25 | Power plug wiring in PVC conduit (4x4 sq.mm. DSR NO. 1.12 |
| 26 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required DSR NO 1.14 |
| 27 | 2 X 1.5 sq. mm + 1X 1.5 sq mm earth wire DSR NO. 1.14.1 |
| 28 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire DSR NO. 1. 14.2 |
| 29 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. DSR NO. 1.24 |
| 30 | 5/6 A switch DSR NO. 1.24.1 |
| 31 | 15/16 A switch DSR NO. 1.24.3 |
| 32 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular piate switch box including connections but excluding modular plate etc, as required. DSR NO. 1.25 |
| 33 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 15 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc as required. DSR NO. 1.45 |
| 34 | Supplying and fixing of following ways surface recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBS (but without MCBs and incomer) as required (Note Vertical type MCB TPDB is normally used where 3 phase outlets are required.) DSR NO 2.5 |
| 35 | 75mmx75mmx60mm Deep |
| 36 | Supply and Celling fan with fan motor of AC permanent insulation, capacitor rating conforming BEE 5 star rating and IS: 374/79 and also comply with S:1709/1984 with latest amendment. The rated voltage 220/240 vait 50Hz 1-ph AC the fan assemble should consist of down rod blades, shackle canopies etc and with double ball breaing system. DSR NO. 19.1 |
| 37 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 38 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests(D.S.R.17.1.1) |
| 39 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. |
| 40 | 20 mm dia nominal bore(D.S.R.18.10.2) |
| 41 | 25 mm dia nominal bore(D.S.R.18.10.3) |
| 42 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : |
| 43 | 15 mm dia nominal bore(D.S.R.18.11.1) |
| 44 | Providing and Fixing UPVC slotted pipe 100 mm dia as per IS:12818 D.S.R No-7758 |
| 45 | Providing and fixing brass stop cock of approved quality : |
| 46 | 15 mm nominal bore(D.S.R.18.16.1) |
| 47 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 48 | 15 mm nominal bore(D.S.R.18.49.1) |
| 49 | Supply and fixing of sign board made of M.S angle iron including supply and cost of all material, labour T&P required templet as directed by the Engineer Incharge. |
| 50 | GST 18 % Please Enable Macros to View BoQ information |