| 1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : |
| 2 | Supply and filling of dry stone soling in foundation trenches tightly hand packed with hand ramming, dressing ,watering incld. carriage of material from source to site of work complete |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 4 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 5 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 6 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 7 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all levels, Thermo-Mechanically Treated bars of grade Fe-500D or more, @95Kg/Cum including all carriages. |
| 9 | Centering and shuttering including strutting propping etc. and removal of form for foundation, footings basses of columns,septic tank and soakage pit slab etc . including all carriages. |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for suspended floors, roofs, landings, balconies and access platforms,stair cases. including all carriages. |
| 11 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand) with Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 12 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 :6 ( 1 cement : 6 fine sand) |
| 13 | Providing and applying white cement based putty 2 mm thick of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete incld.all carriages |
| 14 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate. |
| 15 | Providing wood work in frames of doors, windows, clesrestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners of Imported KD Wood including all carriages . |
| 16 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S pressed butt hinges bright finished of required size with necessary screws 35mm thick Kiln seasoned & chemically treated hollock wood/ KD Wood. |
| 17 | Providing and fixing of 3.5 mm thick glass panes weighing not less than 10kg/sqm. |
| 18 | Distempering with dry distemper of approved brand andmanufacture (two or more coats) and of required shade on new work, over and including water thinnable priming coat to give an even shade including all carriages. |
| 19 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm), including all carriages. |
| 20 | Providing and fixing of Anodised Alumunium Hardware fittings of approved quality and manufacture with all fittings and fixtures incld.carriages complete (L-Drop with lock) |
| 21 | Tower Bolt 150mmx10mm |
| 22 | Tower Bolt 100mmx10mm |
| 23 | Handles 125mm |
| 24 | Handles 100mm |
| 25 | Hooks |
| 26 | Structural steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete, including all carriages. |
| 27 | Providing Hi-Rib colour coated G. S. sheet roofing 0.50mm thick including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required including cost of Ridges hips and valleys. |
| 28 | Applying priming coat With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) including all carriages. |
| 29 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work including all carriages. |
| 30 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer and two or more coats of synthetic enemal paint using structural steel etc. as required In gratings, frames, guard bar, ladder, railings,ornamental grills, gates, brackets and similar works, including all carriages. |
| 31 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 32 | Providing and commisioning lighting points incld wiring for lighting points in 1.5 Sq.mm PVC insulated copper wire and 2.5 Sqmm PVC insulated multi-strand copper wire for lighting sub mains,6 amp 1 way switch,2 mm thick PVC conduit/Channel with bends,junction boxes etc ,6 amp S Pole MCB ,10 amp DP MCB,2 way DB for housing MCB and hylem sheet of ISI mark and approved make with wooden box recessed in wallls with acessories incld all carriages (concelead type 12 watt) |
| 33 | Providing and commissioning heating point incld wiring for heating points in 2 .5 sq.mm PVC insulated multi-strand copper wire and 4 sq.mm PVC insulated multi-strand copper wire for heating sub-mains, 16 AMP switch socket combine,,2 mm thick PVC conduit/Channel with bends, Junction boxes etc , 10 Amp S pole MCB ,2 way DB for housing MCB and hylem sheet of ISI mark and approved make with wooden box recessed in /over wallls with acessories complete incld all carriages |
| 34 | Providing and commissioning of fan point incld wiring for lighting points in 1.5 sqmm PVC insulated multi strand copper wire,1200 mm ceiling fan /225 mm exhaust fan with ceiling roses and PVC square block ,350 watt electronic fan dimmer, 2 mm thick PVC conduit/Channel with bends, Junction boxes etc, 6 mm S pole MCB ,10 amp DP MCB , 2 way DB for housing MCB for lighting circuits and hylam sheet of ISI mark and approved make with wooden box recessed in wallls with acessories complete incld all carriage and costs of Fan and all other material involved. |
| 35 | Carriage of material by Mechanical transport from nearest approved source to site of Work Sand avg.lead-20 kms |
| 36 | Aggregate. avg.lead-20 kms |
| 37 | Bricks avg lead of -50 kms Please Enable Macros to View BoQ information |