| 1 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sqmm FRLS/HFFR PVC insulated copper conductor single core cable 1.5 sqmm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/ PVC conduit including dismantling as required.Group B |
| 2 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(a) 3x2.5 sq mm |
| 3 | (b)6x2.5 sq mm |
| 4 | © 3x4 sq mm |
| 5 | (d)6x4 sq mm |
| 6 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x6 sq. mm + 1x6 sq. mm earth wire |
| 7 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of receesed conduit as required.(a) 25 mm |
| 8 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc.as required. 5/6 A switch |
| 9 | 3 pin 5/6 A socket outlet |
| 10 | Supplying ad fixing suitable size GI box with modular plate and cover in front on surface or in recess , including Providing and fixing 6 pin 5/6 &15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required |
| 11 | Supplying and fixing following size/ modules, GI box along with modular base and cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm) |
| 12 | 6 Module (200mmX75mm) |
| 13 | 12 Module (200mmX150mm) |
| 14 | Supplying and fixing PVC batten/angle holder including connections etc.as required. |
| 15 | Supplying and fixing following way,single pole and neutral, sheet steel, MCB distribution board, 240 V , on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16 way, Double door |
| 16 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc.as required. Single pole |
| 17 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amp |
| 18 | Supplying and fixing suitable size GI Box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 19 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 20 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 21 | Brush Less Direct Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan i/c external connectionswith 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. complete as req 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 22 | Supplying, installation, Testing & Commissioning of 18-22 watt LED surface mounted Batten light of CRCA Sheet Body (Thickness ≥ 0.50 mm) material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/ 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >120<135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineerin-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminum Body (Thickness ≥ 1 |
| 23 | Supplying and fixing modular blanking on the existing modular plate & switch box excluding modular plate as reqd. |
| 24 | Supply of 9 Watt LED Retrofit lamp suitable for B22 holder Please Enable Macros to View BoQ information |