| 1 | SH:- I (Maintenance & Operation)(For Rajiv Gandhi Stadium Bawana, Singhu & Prahladpur Stadium)Providing services for day to day maintenance, upkeep & operation of all electrical installations as per inventory attached on all days including Sunday and holidays etc. as required. |
| 2 | SH:- II (EI Work)Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.a) Group C |
| 3 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.a) Group C |
| 4 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. a) 3 x 1.5 Sq. mm. |
| 5 | b) 3 x 4 Sq. mm. |
| 6 | c) 3 x 6 Sq. mm. |
| 7 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit asrequired.a) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 8 | b) 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 9 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 10 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 11 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.a) Upto 35 sq. mm |
| 12 | b) Above 35 sq. mm and upto 95 sq. mm |
| 13 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required |
| 14 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.a) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 15 | b) 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 16 | Supplying of one number PVC insulated and PVC sheathed / XLPE with Al. conductor armoured power cable of 1.1 kV grade of following size complete as required.a) 4x16 sqmm |
| 17 | b) 4x25 sqmm |
| 18 | c) 4x50 sqmm |
| 19 | Supplying and drawing following sizes of PVC sheathed & XLPE insulated Copper conductor multicore unarmoured cable of 1100 Volts with upto Date Amendments in the existing poles and bracket from cable termination connector to the fitting i/c providing suitable lugs connections etc. as reqd.a) 3 core 1.5 sq.mm |
| 20 | Rewinding of 1200/1400 mm all type of ceiling fan with suitable size super enamelled copper wire after dismantling from the existing position and refixing the same on the existing position/ceiling with suitable size nut, bolts, cotter pin, rubber reel and supplying/fixing the same wherever found defective/missing during inspection for safe running of fan and cleaning the fan and fan blade with detergent and making connection with 1.5 sq. mm FRLS PVC insulated, copper conductor wire, testing and commissioning etc. complete as required and buy back the dismantled material. |
| 21 | Rewinding of 300/380 mm exhaust fan after dismantling from the existing position with suitable size super enamelled copper wire and refixing the same on the existing hole alongwith nuts, bolts and washer and cleaning the blade with detergent and making connection with 1.5 sq. mm FRLS PVC insulated, copper conductor wire, testing commissioning etc. as required and buy back the dismantled material. |
| 22 | Supplying and fixing of following electrical accessories in the existing cubical panel, DBs feeder pillar including connection, inter connection with suitable size connector complete etc as required.a) Three phase LED Ammeter (class .5) with selector switch and CT having ration 50/5 A |
| 23 | b) Three phase LED Voltmeter (class .5) with selector Switch |
| 24 | c) 1 Module Red-Yellow-Blue Indicating Lights |
| 25 | d) Digital timer |
| 26 | e) 70 amp 3 Phase Contactor (MNX 70) |
| 27 | Provision for pole / wall mounted box (300X200x105) mm size made out of (SMC) sheet moulding compound dust & wheather proof with front openable hinged type cover with locking arrangement i/c providing and fixing of following accessories on existing pole / wall with suitable arrangement as required:a) 32 amp 5 way connector with bakelite baseb) 6 amp SP MCB \\"C\\" curve (10 KA )- 1 No.c) Earth stud - 2 setsd) 40 x 5 clamp with 2 nos 3/8\\" Nuts & Bolts - 1 set as required.e) push and clip handle to close/open- 1no |
| 28 | Repairing of all type of damage pumps (of water supply/sewage etc. pump sets) i/c dismantling from site, shifting to workshop, turning & polishing of shaft, replacement of GM bearing bush, ball bearing, O ring, thrust bush, thrust plate etc. all items/parts i/c buy back of dismantle material to contractor (dismantle material shall retained with agency) i/c trasfer from workshop to site of work including reassembled, isnatllation, testing and commissioning etc complete as required at site.(a) upto 3 HP pump motor sets (all types) |
| 29 | (b) above 3 HP and upto 5 HP pump motor sets (all Types) |
| 30 | (c) above 5 HP and upto 7.5 HP pump motor sets (all types) |
| 31 | Dismantling of exisitng motor pump sets, transfer to workshop from site, rewinding of Motor with super enameled copper wire including inspection of motor suspension arrangement and tightness of nuts and bolts, cotter pin, rubber reel and replacement of the same wherever found defective during inspection for safe running of motor i/c cleaning the motor with detergent i/c less for old dismantle complete etc as required icluding reassemble, transfer to site of work including installation, testing and commissioning etc. complete as required at site.(a) upto 3 HP motor pump sets (all types) |
| 32 | (b) above 3 HP and upto 5 HP pump motor sets (all types) |
| 33 | (c) above 5 HP and upto 7.5 HP pump motor sets (all types) |
| 34 | SITC of 5 HP DOL Starter with wideband coil having relay range 6-10 A suitable for 415V 50Hz, 3 phase motor complete with sheet enclosure, start stop push button, on off LED indication lamp and all other accessories including connections & testing etc complete as required. |
| 35 | SITC of 10 HP / 7.5 kw fully automatic star delta Submersible Pump Starter with wideband coil having relay range 9-14A suitable for 415V 50Hz, 3 phase motor complete with sheet enclouser, ammeter, voltmeter, start stop push button, on off LED indication lamp, auto mannual slector switch and all other accessories including connections & testing credit of dismantle etc complete as required. |
| 36 | Lifting of existing submersible bore well / open well 3 HP to 10 HP capacity Pump set from the bore well with the help of chain pulley block & tripod stand i/c cartage charge at site from the work shop. |
| 37 | Lowering of 3 HP to 10 HP capacity bore well/open well pumpset in the bore well with the help of chain pulley block and tripod stand i/c cartage charge pump set from work shop to site. |
| 38 | Comprehensive maintenance of following LPH R.O. Plants i/c supplying and replacement of all kind of filters each month, backwash with anti scalent liquid, repair/replacement of defective parts including rewinding/repair of motors, Dosing pump (if any) providing chlorin required to maintain suitable TDS, replacement of membrane atleast once in 6 month i/c monthly Service from OEM or agency authorised by OEM, providing monthly engineer visit and service report complete etc as required. (2 Nos. installed at Rajiv Gandhi Stadium) |
| 39 | Supplying and dosing of anti scalent chemical in plant regularly with operation of RO plant suitable for more than 1500 TDS water etc. as required. |
| 40 | Supplying replacement of TFC Membrane of size 4\\"X40\\" at existing RO Plant i/c testing, commssioning complete etc as required. |
| 41 | Providing and replacment micron cartidge micron fillter of size 20\\" long & 4\\" dia filtering upto 5 micron suspended particles at existing RO system i/c testing commissioning complete as required. |
| 42 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - chargea) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 43 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level a) 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 44 | Cement Plaster (In Fine Sand) 12 mm cement plaster of mixa) 1:4 (1 cement: 4 fine sand) |
| 45 | SH:- III (Supply of materials)Note:- No labour is considered for fixing of these itemsS.P. 5/6 A, one way modular switch, ISI marked |
| 46 | S.P. 15/16 A, one way modular switch, ISI marked |
| 47 | 3 pin 5/6 A modular socket outlet, ISI marked |
| 48 | 6 pin 15/16 A modular socket outlet, ISI marked |
| 49 | Stepped type Modular Fan regulator (2 module) |
| 50 | Modular base & cover plate for 4 Module |
| 51 | Modular base & cover plate for 6 Module |
| 52 | Modular base & cover plate for 12 Module |
| 53 | 6 A, to 32 A, ratings, SP MCB, \\"C\\" curve, 10 KA breaking capacity |
| 54 | 6 A, to 32 A, ratings, SPN MCB, \\"C\\" curve, 10 KA breaking capacity |
| 55 | 3 pole MCCB, 100A, 16kA Ics=100% Icu and Operational Voltage 690V |
| 56 | 3 pole MCCB, 125A, 16kA Ics=100% Icu and Operational Voltage 690V |
| 57 | 3 pole MCCB, 150/160A, 16kA Ics=100% Icu and Operational Voltage 690V |
| 58 | 3 pole MCCB, 200A, 16kA Ics=100% Icu and Operational Voltage 690V |
| 59 | 3 pole MCCB, 250A, 25kA Ics=100% Icu and Operational Voltage 690V |
| 60 | 3 pole MCCB, 315A, 35kA Ics=100% Icu and Operational Voltage 690V |
| 61 | 1200mm ceiling fan with Brush Less Direct Current (BLDC) Motor, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 62 | 40 Watt LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 63 | 90 Watt LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) |
| 64 | 150 Watt LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy 105 <120 lm/Watt) |
| 65 | 40 Amp DPMCB, 415 V, 10 kA, “C” curve |
| 66 | 63 Amp TPMCB, 415 V, 10 kA, “C” curve |
| 67 | Heavy duty exhaust fan of 300 mm sweep 900 rpm with louvers/shutters |
| 68 | SH-IV (Credit of dismantle materials) Less credit for dismantle material recevied from the work.Copper conductor PVC insulated assorted size/capacity wires in cut pieces |
| 69 | Assorted Switch, Socket fan regulator |
| 70 | GI/MS/DB Box assorted size |
| 71 | MCB assorted size/capacity etc. |
| 72 | MCCBs upto 200 Amp TP/FP assorted size capacity Please Enable Macros to View BoQ information |