Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-03-2026 | Extension of Time of Bid Submission of Grp. 25 (Package No. AS15649, AS15650, AS15651, AS15652, AS15654, AS15655, AS15725, AS15727, AS15730) | Date | 10-04-2026 |
| Sl. No. | Item Description |
| 1 | MRL07-Goraimari to Pamegaon NC via No 2 GhagarmukhPackage No. AS15649 |
| 2 | MRL10-Gereki No.1 (Taku Gaon) to Pamegaon NC Package No. AS15650 |
| 3 | MRL04-Phulanibari to Ghulichuk Via Bhuma Chapori LPPackage No. AS15651 |
| 4 | MRL05-Hechamara to Balijan LP SchoolPackage No. AS15652 |
| 5 | MRL08-CHAMORDUBI TINIALI TO BHIMPARA MATHAURI Package No. AS15654 |
| 6 | MRL03-Taku Tiniali to Bhimpara GP OfficePackage No. AS15655 |
| 7 | MRL01-9 by 6 Koilamari Nepali main gaon road to Balichapori DejooPackage No. AS15725 |
| 8 | MRL10-Koilamari TE Link Road 7Package No. AS15727 |
| 9 | MRL05-Filip Urang Road 1Package No. AS15730 |
| 10 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201.[SOR 25-26] [item No.2.2]By Manual Means (a) In area of non thorny jungle |
| 11 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. [SOR 25-26] [item No.3.14] (i) Private Land |
| 12 | Construction of embankment with approved material obtained from borrow pitswith a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 [SOR 25-26] [item No.3.4] (i) Private Land |
| 13 | Granular Sub-base with Well Graded Material (Table 400.1)Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. [SOR 25-26] [item No.4.1] (A) By Mix in Place Method,(i) For Grading I Material |
| 14 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405.[SOR 25-26] [item No.4.7] (II) WBM Grading 2,Using stone screening Type-B 11.2 mm for Gr.II,(B) By Mechanical Means |
| 15 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405..[SOR 25-26] [item No.4.7] (III) WBM Grading 3,Using stone screening Type-B 11.2 mm for Gr.III,(B) By Mechanical Means |
| 16 | Prime Coat Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 .[SOR 25-26] [item No.5.1](i) Low porosity |
| 17 | Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503..[SOR 25-26] [item No.5.2(III)] |
| 18 | Mix Seal Surfacing Providing, laying and rolling of close-graded premix surfacing material of 20mm thickness composed of 11.2mm to0.9mm (Type-A) or 13.2mm to 0.9mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10kN static roller and finishing to required level and grades as per Technical Specification Clause 509 [SOR 25-26] [item No.5.11](II) By Mechanical Means(B) Type B,(ii) Bitumen (S-65) |
| 19 | Kilometre stone Reinforced cement concrete M15 grade kilometre local stone of standard design asper IRC:8 fixing in position including painting and printing , etc as per drawing and technical specification clause 1703.[SOR 25-26] [item No.10.10] (ii) Ordinary Kilometer Stone (Precast) |
| 20 | Kilometre stone Reinforced cement concrete M15 grade kilometre local stone of standard design asper IRC:8 fixing in position including painting and printing , etc as per drawing and technical specification clause 1703.[SOR 25-26] [item No.10.10] (iii) 200 m stone (precast) |
| 21 | Providing and fixing of retro-reflectorised cautionary,mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5mm thick supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450mm x 600mm, 600mm below ground level as per drawing sand Technical Specification Clause 801 .[SOR 25-26] [item No.10.2] (A) Retro-reflectorised Traffic Signs (i) 900mm equilateral triangle |
| 22 | Providing and fixing of retro-reflectorised cautionary,mandatory and informatorysign as per IRC:67 made of encapsulated lens type reflective sheeting videClause 1701.2.3 fixed over aluminium sheeting, 1.5mm thick supported on amild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground bymeans of properly designed foundation with M15 grade cement concrete 450mm x 450mm x 600mm, 600mm below ground level as per drawing sandTechnical Specification Clause 801 .[SOR 25-26] [item No.10.2] (A) Retro-reflectorised Traffic Signs (ii) 600mm equilateral triangle |
| 23 | Providing and fixing of retro-reflectorised cautionary,mandatory and informatorysign as per IRC:67 made of encapsulated lens type reflective sheeting videClause 1701.2.3 fixed over aluminium sheeting, 1.5mm thick supported on amild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground bymeans of properly designed foundation with M15 grade cement concrete 450mm x 450mm x 600mm, 600mm below ground level as per drawing sandTechnical Specification Clause 801 .[SOR 25-26] [item No.10.2] (A) Retro-reflectorised Traffic Signs (iii) 600mm circular |
| 24 | Providing and fixing of retro-reflectorised cautionary,mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5mm thick supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450mm x 600mm, 600mm below ground level as per drawing sand Technical Specification Clause 801 .[SOR 25-26] [item No.10.2] (A) Retro-reflectorised Traffic Signs (iv) 800mm x 600mm rectangular |
| 25 | Providing and fixing of typical Logo Board with PMGSY Logo as per MORD specifications and drawing. 1 nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 1 nos. steel plate will be welded horizontally with 1 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The 1 no steel plate will be welded vertically to 1 no. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
| 26 | Providing and fixing of typical Citizens Information Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick duly welded with 5mm thick steel plate on back on edgtheisc.k TMheS 4s hneoest. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
| 27 | Providing and fixing of typical Citizens Information Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick duly welded with 5mm thick steel plate on back on edgtheisc.k TMheS 4s hneoest. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
| 28 | Title Informatory Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 4 nos. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1[SOR 25-26] [item No.10.16] |
| 29 | Painting on Concrete/Steel Surfaces with Epoxy Painting two coats including prime coat with epoxy paint of approved brand on concrete/steel surfaces after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701[SOR 25-26] [item No.10.7] |
| 30 | Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.[SOR 25-26] [item No.16.34] |
| 31 | BOX CULVERT - 1 x3M x3M Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.[SOR 25-26] [item No.11.1]I Ordinary soil ,Upto 3 m depth |
| 32 | Fillling in foundation trenches as per drawing and technical specification Clause305.3.9 [SOR 25-26] [item No.11.2]i Sand filling |
| 33 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. [SOR 25-26] [item No.11.4](I). With crushed stone. (B).P.C.C grade M 15. Nominal mix 1:2.5:5 |
| 34 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203.[SOR 25-26] [item No.11.4] (I). With crushed stone.(C). P.C.C grade M 20. Nominal mix 1:2:4 |
| 35 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. [SOR 25-26] [item No.11.4] (I). With crushed stone. (D). R.C.C grade M 20. Nominal mix 1:2:4 |
| 36 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204. [SOR 25-26] [item No.12.5] (I). With crushed stone. (D). R.C.C grade M 25. For height upto 5 m |
| 37 | Supplying ,fitting and placing TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-550 N/sqmm (Fe-550D from Primary Producer (TATA/SAIL/EsserSteel/Jindalsteel/Shyamsteel/RINL) in substructrue complete as per drawings and technical specification Clauses 1000 and 1202. [SOR 25-26] [item No.11.7] |
| 38 | Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 [SOR 25-26] [item No.12.6] |
| 39 | Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 [SOR 25-26] [item No.13.6] |
| 40 | Providing and laying cement concrete wearing course M30 grade including reinforcement complete as per drawing and technical specifications Clause 800 and 1206.3 [SOR 25-26] [item No.13.5] (i) With crushed stone |
| 41 | Providing pressure relief pipes 100mm dia in bottom slab of box cell on a filter media base of 500mmx500mm as per drawing and technical specification Cluse 1205.5.7 [SOR 25-26] [item No.12.14] |
| 42 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 [SOR 25-26] [item No.12.9] |
| 43 | Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3 [SOR 25-26] [item No.14.8] |
| 44 | Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification [SOR 25-26] [item No.12.10] A. Granular material |
| 45 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201.[SOR 25-26] [item No.2.2]By Manual Means (a) In area of non thorny jungle |
| 46 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. [SOR 25-26] [item No.3.14] (i) Private Land |
| 47 | Construction of embankment with approved material obtained from borrow pitswith a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 [SOR 25-26] [item No.3.4] (i) Private Land |
| 48 | Granular Sub-base with Well Graded Material (Table 400.1)Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. [SOR 25-26] [item No.4.1] (A) By Mix in Place Method,(i) For Grading I Material |
| 49 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405.[SOR 25-26] [item No.4.7] (II) WBM Grading 2,Using stone screening Type-B 11.2 mm for Gr.II,(B) By Mechanical Means |
| 50 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405..[SOR 25-26] [item No.4.7] (III) WBM Grading 3,Using stone screening Type-B 11.2 mm for Gr.III,(B) By Mechanical Means |
| 51 | Prime Coat Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 .[SOR 25-26] [item No.5.1](i) Low porosity |
| 52 | Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503..[SOR 25-26] [item No.5.2(III)] |
| 53 | Mix Seal Surfacing Providing, laying and rolling of close-graded premix surfacing material of 20mm thickness composed of 11.2mm to0.9mm (Type-A) or 13.2mm to 0.9mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10kN static roller and finishing to required level and grades as per Technical Specification Clause 509 [SOR 25-26] [item No.5.11](II) By Mechanical Means(B) Type B,(ii) Bitumen (S-65) |
| 54 | Kilometre stone Reinforced cement concrete M15 grade kilometre local stone of standard design asper IRC:8 fixing in position including painting and printing , etc as per drawing and technical specification clause 1703.[SOR 25-26] [item No.10.10] (ii) Ordinary Kilometer Stone (Precast) |
| 55 | Kilometre stone Reinforced cement concrete M15 grade kilometre local stone of standard design asper IRC:8 fixing in position including painting and printing , etc as per drawing and technical specification clause 1703.[SOR 25-26] [item No.10.10] (iii) 200 m stone (precast) |
| 56 | Providing and fixing of retro-reflectorised cautionary,mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5mm thick supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450mm x 600mm, 600mm below ground level as per drawing sand Technical Specification Clause 801 .[SOR 25-26] [item No.10.2] (A) Retro-reflectorised Traffic Signs (i) 900mm equilateral triangle |
| 57 | Providing and fixing of retro-reflectorised cautionary,mandatory and informatorysign as per IRC:67 made of encapsulated lens type reflective sheeting videClause 1701.2.3 fixed over aluminium sheeting, 1.5mm thick supported on amild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground bymeans of properly designed foundation with M15 grade cement concrete 450mm x 450mm x 600mm, 600mm below ground level as per drawing sandTechnical Specification Clause 801 .[SOR 25-26] [item No.10.2] (A) Retro-reflectorised Traffic Signs (ii) 600mm equilateral triangle |
| 58 | Providing and fixing of retro-reflectorised cautionary,mandatory and informatorysign as per IRC:67 made of encapsulated lens type reflective sheeting videClause 1701.2.3 fixed over aluminium sheeting, 1.5mm thick supported on amild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground bymeans of properly designed foundation with M15 grade cement concrete 450mm x 450mm x 600mm, 600mm below ground level as per drawing sandTechnical Specification Clause 801 .[SOR 25-26] [item No.10.2] (A) Retro-reflectorised Traffic Signs (iii) 600mm circular |
| 59 | Providing and fixing of retro-reflectorised cautionary,mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5mm thick supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450mm x 600mm, 600mm below ground level as per drawing sand Technical Specification Clause 801 .[SOR 25-26] [item No.10.2] (A) Retro-reflectorised Traffic Signs (iv) 800mm x 600mm rectangular |
| 60 | Providing and fixing of typical Logo Board with PMGSY Logo as per MORD specifications and drawing. 1 nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 1 nos. steel plate will be welded horizontally with 1 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The 1 no steel plate will be welded vertically to 1 no. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
| 61 | Providing and fixing of typical Citizens Information Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick duly welded with 5mm thick steel plate on back on edgtheisc.k TMheS 4s hneoest. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
| 62 | Providing and fixing of typical Citizens Information Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick duly welded with 5mm thick steel plate on back on edgtheisc.k TMheS 4s hneoest. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
| 63 | Title Informatory Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 4 nos. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1[SOR 25-26] [item No.10.16] |
| 64 | Painting on Concrete/Steel Surfaces with Epoxy Painting two coats including prime coat with epoxy paint of approved brand on concrete/steel surfaces after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701[SOR 25-26] [item No.10.7] |
| 65 | Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.[SOR 25-26] [item No.16.34] |
| 66 | Cross Drainage Works (1x 1000) Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.[SOR 25-26] [item No.11.1]I Ordinary soil ,Upto 3 m depth |
| 67 | Bedding of pipe [SOR 25-26] [item No.9.2](A) Type A (Concrete Cradle) BeddingLaying concrete cradle beddingwithM15GradeCement Concrete as perClause 1105 (i) |
| 68 | Plain Cement Concrete M10 (1:3:6 nominal mix) in leveling course below open foundation of Head Walls as per drawing and Technical specification clause 1109.[SOR 25-26] [item No.11.4]I With crushed Stone (i) Nominal mix 1:3:6 |
| 69 | Brick Masonry Work in cement mortar in foundation of Head walls complete exculding pointing and plastering as per drawing and technical specification Clause 1109 [SOR 25-26] [item No.11.5]ii. Brick Masonry in 1:4 cement mortar |
| 70 | Reinforced Cement Concrete Pipe NP3 in Single RowProviding and laying reinforced cement concrete pipe NP3 for culverts as per design on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.[SOR 25-26] [item No.9.3]ii) 1000 mm dia |
| 71 | Plastering with Cement Mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification.[SOR 25-26] [item No.12.3] |
| 72 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. i) By Mechanical Means. a) In area of non-thorny jungle Rate as per SOR 2025-2026, 2.2, (ii), (a) |
| 73 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5(i) Private Land Rate as per SOR 2025-2026, 3.4 / 301.5 |
| 74 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.(i) Private LandFor ShoulderRate as per SOR 2025-2026, 3.14 / 303.1 |
| 75 | Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.(A) By Mix in Place Methodii) For Grading II MaterialQty. as per Statement No. - 2Rate as per SOR 2025-2026, 4.1 / 401 |
| 76 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. 1) Grading-II. (A) By By Manuall Means Rate as per SOR 2025-2026, 4.7 / 405 |
| 77 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 3 as per Technical Specification Clause 405. 1) Grading-III. (A) By By Manuall Means Rate as per SOR 2025-2026, 4.7 / 406 |
| 78 | Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502.(i) Low PorosityQty. as per Statement No. - 2Rate as per SOR 2025-2026, 5.1 / 502 |
| 79 | Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.Qty. as per Statement No. - 2Rate as per SOR 2025-2026, 5.2 / 503 |
| 80 | Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 508. By Mechanical Means. Type B. (ii) Bitumen (S-65) Rate as per SOR 2025-2026, 5.11, Type B (ii)/508 |
| 81 | Kilometer StoneReinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause1703ii) Ordinary Kilometer Stone (Precast) Rate as per SOR 2025-2026, 10.10, (ii) / 1703 |
| 82 | Kilometer StoneReinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause1703iii) 200 m stone (precast) Rate as per SOR 2025-2026, 10.10, (iii) / 1703 |
| 83 | Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801ii) 600mm equilateral triangle Rate as per SOR 2025-2026, 10.2, A, I, (ii) / 801 |
| 84 | Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801iii) 600mm circular Rate as per SOR 2025-2026, 10.2, A, I, (iii) / 801 |
| 85 | Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801v) 600mm x 450mm rectangular Rate as per SOR 2025-2026, 10.2, A, I, (v) / 801 |
| 86 | Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801vi) 600mm x 600mm square Rate as per SOR 2025-2026, 10.2, A, I, (vi) / 801 |
| 87 | Road Marking with Hot Applied Thermoplastic Compound withReflectorising Glass Beads on Bituminous SurfaceProviding and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specificationsRate as per SOR 2025-2026, 16.34 |
| 88 | PMGSY Title informatory sign board Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will primer and two coats of epoxy paint as per drawing Clause 1710 and Annexure 1700.1. Rate as per SOR 2025-2026, 10.16 |
| 89 | Providing and fixing of typical Maintenance Information BoardProviding and fixing of typical Citizens Information Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 4 nos. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 Rate as per SOR 2025-2026, 10.16 |
| 90 | Providing and Fixing PMGSY Logo BoardProviding and fixing of typical Logo Board with PMGSY Logo as per MORD specifications and drawing. 1 nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 1 nos. steel plate will be welded horizontally with 1 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The 1 no steel plate will be welded vertically to 1 no. 75mm x 75mm of 12 |SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, borderetc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 Rate as per SOR 2025-2026, 10.16 |
| 91 | Providing and Fixing Citizens Information BoardProviding and fixing of typical Citizens Information Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 4 nos. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 Rate as per SOR 2025-2026, 10.16 |
| 92 | Cross Drainage WorksEarthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.Rate as per SOR 2025-2026, 11.1 |
| 93 | PCC M10(1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawing and technical specification clause 1109 Rate as per SOR 2025-2026, 9.7 |
| 94 | Laying (First Class) bedding on well compacted approved granular material as per Clause 1105 (ii)Rate as per SOR 2025-2026, 9.2 |
| 95 | Brick masonry work in cement mortar in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 600, 1202 & 1203. (ii) Brick masonry in 1:4 cement mortar Rate as per SOR 2025-2026, 9.8 |
| 96 | Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204Rate as per SOR 2025-2026, 9.11 |
| 97 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.(B) 1000 mm diaRate as per SOR 2025-2026, 9.3 |
| 98 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. i) By Mechanical Means. a) In area of non-thorny jungle Rate as per SOR 2025-2026, 2.2, (ii), (a) |
| 99 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5(i) Private Land Rate as per SOR 2025-2026, 3.4 / 301.5 |
| 100 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.(i) Private LandFor ShoulderRate as per SOR 2025-2026, 3.14 / 303.1 |
| 101 | Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.(A) By Mix in Place Methodii) For Grading II MaterialQty. as per Statement No. - 2Rate as per SOR 2025-2026, 4.1 / 401 |
| 102 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. 1) Grading-II. (A) By By Manuall Means Rate as per SOR 2025-2026, 4.7 / 405 |
| 103 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 3 as per Technical Specification Clause 405. 1) Grading-III. (A) By By Manuall Means Rate as per SOR 2025-2026, 4.7 / 406 |
| 104 | Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502.(i) Low PorosityQty. as per Statement No. - 2Rate as per SOR 2025-2026, 5.1 / 502 |
| 105 | Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.Qty. as per Statement No. - 2Rate as per SOR 2025-2026, 5.2 / 503 |
| 106 | Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 508. By Mechanical Means. Type B. (ii) Bitumen (S-65) Rate as per SOR 2025-2026, 5.11, Type B (ii)/508 |
| 107 | Kilometer StoneReinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause1703ii) Ordinary Kilometer Stone (Precast) Rate as per SOR 2025-2026, 10.10, (ii) / 1703 |
| 108 | Kilometer StoneReinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause1703iii) 200 m stone (precast) Rate as per SOR 2025-2026, 10.10, (iii) / 1703 |
| 109 | Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801ii) 600mm equilateral triangle Rate as per SOR 2025-2026, 10.2, A, I, (ii) / 801 |
| 110 | Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801iii) 600mm circular Rate as per SOR 2025-2026, 10.2, A, I, (iii) / 801 |
| 111 | Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801v) 600mm x 450mm rectangular Rate as per SOR 2025-2026, 10.2, A, I, (v) / 801 |
| 112 | Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801vi) 600mm x 600mm square Rate as per SOR 2025-2026, 10.2, A, I, (vi) / 801 |
| 113 | Road Marking with Hot Applied Thermoplastic Compound withReflectorising Glass Beads on Bituminous SurfaceProviding and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specificationsRate as per SOR 2025-2026, 16.34 |
| 114 | PMGSY Title informatory sign board Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will primer and two coats of epoxy paint as per drawing Clause 1710 and Annexure 1700.1. Rate as per SOR 2025-2026, 10.16 |
| 115 | Providing and fixing of typical Maintenance Information BoardProviding and fixing of typical Citizens Information Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 4 nos. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 Rate as per SOR 2025-2026, 10.16 |
| 116 | Providing and Fixing PMGSY Logo BoardProviding and fixing of typical Logo Board with PMGSY Logo as per MORD specifications and drawing. 1 nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 1 nos. steel plate will be welded horizontally with 1 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The 1 no steel plate will be welded vertically to 1 no. 75mm x 75mm of 12 |SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, borderetc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 Rate as per SOR 2025-2026, 10.16 |
| 117 | Providing and Fixing Citizens Information BoardProviding and fixing of typical Citizens Information Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 4 nos. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 Rate as per SOR 2025-2026, 10.16 |
| 118 | Cross Drainage WorksEarthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.Rate as per SOR 2025-2026, 11.1 |
| 119 | PCC M10(1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawing and technical specification clause 1109 Rate as per SOR 2025-2026, 9.7 |
| 120 | Laying (First Class) bedding on well compacted approved granular material as per Clause 1105 (ii)Rate as per SOR 2025-2026, 9.2 |
| 121 | Brick masonry work in cement mortar in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 600, 1202 & 1203. (ii) Brick masonry in 1:4 cement mortar Rate as per SOR 2025-2026, 9.8 |
| 122 | Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204Rate as per SOR 2025-2026, 9.11 |
| 123 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.(B) 1000 mm diaRate as per SOR 2025-2026, 9.3 |
| 124 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201.[SOR 25-26] [item No.2.2]By Manual Means (a) In area of non thorny jungle |
| 125 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. [SOR 25-26] [item No.3.14] (i) Private Land |
| 126 | Construction of embankment with approved material obtained from borrow pitswith a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 [SOR 25-26] [item No.3.4] (i) Private Land |
| 127 | Granular Sub-base with Well Graded Material (Table 400.1)Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. [SOR 25-26] [item No.4.1] (A) By Mix in Place Method,(i) For Grading I Material |
| 128 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405.[SOR 25-26] [item No.4.7] (II) WBM Grading 2,Using stone screening Type-B 11.2 mm for Gr.II,(B) By Mechanical Means |
| 129 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405..[SOR 25-26] [item No.4.7] (III) WBM Grading 3,Using stone screening Type-B 11.2 mm for Gr.III,(B) By Mechanical Means |
| 130 | Prime Coat Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 .[SOR 25-26] [item No.5.1](i) Low porosity |
| 131 | Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503..[SOR 25-26] [item No.5.2(III)] |
| 132 | Mix Seal Surfacing Providing, laying and rolling of close-graded premix surfacing material of 20mm thickness composed of 11.2mm to0.9mm (Type-A) or 13.2mm to 0.9mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10kN static roller and finishing to required level and grades as per Technical Specification Clause 509 [SOR 25-26] [item No.5.11](II) By Mechanical Means(B) Type B,(ii) Bitumen (S-65) |
| 133 | Kilometre stone Reinforced cement concrete M15 grade kilometre local stone of standard design asper IRC:8 fixing in position including painting and printing , etc as per drawing and technical specification clause 1703.[SOR 25-26] [item No.10.10] (ii) Ordinary Kilometer Stone (Precast) |
| 134 | Kilometre stone Reinforced cement concrete M15 grade kilometre local stone of standard design asper IRC:8 fixing in position including painting and printing , etc as per drawing and technical specification clause 1703.[SOR 25-26] [item No.10.10] (iii) 200 m stone (precast) |
| 135 | Providing and fixing of retro-reflectorised cautionary,mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5mm thick supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450mm x 600mm, 600mm below ground level as per drawing sand Technical Specification Clause 801 .[SOR 25-26] [item No.10.2] (A) Retro-reflectorised Traffic Signs (i) 900mm equilateral triangle |
| 136 | Providing and fixing of retro-reflectorised cautionary,mandatory and informatorysign as per IRC:67 made of encapsulated lens type reflective sheeting videClause 1701.2.3 fixed over aluminium sheeting, 1.5mm thick supported on amild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground bymeans of properly designed foundation with M15 grade cement concrete 450mm x 450mm x 600mm, 600mm below ground level as per drawing sandTechnical Specification Clause 801 .[SOR 25-26] [item No.10.2] (A) Retro-reflectorised Traffic Signs (ii) 600mm equilateral triangle |
| 137 | Providing and fixing of retro-reflectorised cautionary,mandatory and informatorysign as per IRC:67 made of encapsulated lens type reflective sheeting videClause 1701.2.3 fixed over aluminium sheeting, 1.5mm thick supported on amild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground bymeans of properly designed foundation with M15 grade cement concrete 450mm x 450mm x 600mm, 600mm below ground level as per drawing sandTechnical Specification Clause 801 .[SOR 25-26] [item No.10.2] (A) Retro-reflectorised Traffic Signs (iii) 600mm circular |
| 138 | Providing and fixing of retro-reflectorised cautionary,mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5mm thick supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450mm x 600mm, 600mm below ground level as per drawing sand Technical Specification Clause 801 .[SOR 25-26] [item No.10.2] (A) Retro-reflectorised Traffic Signs (iv) 800mm x 600mm rectangular |
| 139 | Providing and fixing of typical Logo Board with PMGSY Logo as per MORD specifications and drawing. 1 nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 1 nos. steel plate will be welded horizontally with 1 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The 1 no steel plate will be welded vertically to 1 no. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
| 140 | Providing and fixing of typical Citizens Information Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick duly welded with 5mm thick steel plate on back on edgtheisc.k TMheS 4s hneoest. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
| 141 | Providing and fixing of typical Citizens Information Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick duly welded with 5mm thick steel plate on back on edgtheisc.k TMheS 4s hneoest. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
| 142 | Title Informatory Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 4 nos. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1[SOR 25-26] [item No.10.16] |
| 143 | Painting on Concrete/Steel Surfaces with Epoxy Painting two coats including prime coat with epoxy paint of approved brand on concrete/steel surfaces after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701[SOR 25-26] [item No.10.7] |
| 144 | Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.[SOR 25-26] [item No.16.34] |
| 145 | BOX CULVERT - 1 x2M x2M Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.[SOR 25-26] [item No.11.1]I Ordinary soil ,Upto 3 m depth |
| 146 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. [SOR 25-26] [item No.11.4](I). With crushed stone. (B).P.C.C grade M 15. Nominal mix 1:2.5:5 |
| 147 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203.[SOR 25-26] [item No.11.4] (I). With crushed stone.(C). P.C.C grade M 20. Nominal mix 1:2:4 |
| 148 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. [SOR 25-26] [item No.11.4] (I). With crushed stone. (D). R.C.C grade M 20. Nominal mix 1:2:4 |
| 149 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204. [SOR 25-26] [item No.12.5] (I). With crushed stone. (D). R.C.C grade M 25. For height upto 5 m |
| 150 | Supplying ,fitting and placing TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-550 N/sqmm (Fe-550D from Primary Producer (TATA/SAIL/EsserSteel/Jindalsteel/Shyamsteel/RINL) in substructrue complete as per drawings and technical specification Clauses 1000 and 1202. [SOR 25-26] [item No.11.7] |
| 151 | Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 [SOR 25-26] [item No.12.6] |
| 152 | Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 [SOR 25-26] [item No.13.6] |
| 153 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 [SOR 25-26] [item No.12.9] |
| 154 | Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3 [SOR 25-26] [item No.14.8] |
| 155 | Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification [SOR 25-26] [item No.12.10] A. Granular material |
| 156 | BOX CULVERT - 2 x3M x3M Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.[SOR 25-26] [item No.11.1]I Ordinary soil ,Upto 3 m depth |
| 157 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. [SOR 25-26] [item No.11.4](I). With crushed stone. (B).P.C.C grade M 15. Nominal mix 1:2.5:5 |
| 158 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203.[SOR 25-26] [item No.11.4] (I). With crushed stone.(C). P.C.C grade M 20. Nominal mix 1:2:4 |
| 159 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. [SOR 25-26] [item No.11.4] (I). With crushed stone. (D). R.C.C grade M 20. Nominal mix 1:2:4 |
| 160 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204. [SOR 25-26] [item No.12.5] (I). With crushed stone. (D). R.C.C grade M 25. For height upto 5 m |
| 161 | Supplying ,fitting and placing TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-550 N/sqmm (Fe-550D from Primary Producer (TATA/SAIL/EsserSteel/Jindalsteel/Shyamsteel/RINL) in substructrue complete as per drawings and technical specification Clauses 1000 and 1202. [SOR 25-26] [item No.11.7] |
| 162 | Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 [SOR 25-26] [item No.12.6] |
| 163 | Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 [SOR 25-26] [item No.13.6] |
| 164 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 [SOR 25-26] [item No.12.9] |
| 165 | Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3 [SOR 25-26] [item No.14.8] |
| 166 | Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification [SOR 25-26] [item No.12.10] A. Granular material |
| 167 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. i) By Mechanical Means. a) In area of non-thorny jungle Rate as per SOR 2025-2026, 2.2, (ii), (a) |
| 168 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5(i) Private Land Rate as per SOR 2025-2026, 3.4 / 301.5 |
| 169 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.(i) Private LandFor ShoulderRate as per SOR 2025-2026, 3.14 / 303.1 |
| 170 | Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.(A) By Mix in Place Methodii) For Grading II MaterialQty. as per Statement No. - 2Rate as per SOR 2025-2026, 4.1 / 401 |
| 171 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. 1) Grading-II. (A) By By Manuall Means Rate as per SOR 2025-2026, 4.7 / 405 |
| 172 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 3 as per Technical Specification Clause 405. 1) Grading-III. (A) By By Manuall Means Rate as per SOR 2025-2026, 4.7 / 406 |
| 173 | Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502.(i) Low PorosityQty. as per Statement No. - 2Rate as per SOR 2025-2026, 5.1 / 502 |
| 174 | Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.Qty. as per Statement No. - 2Rate as per SOR 2025-2026, 5.2 / 503 |
| 175 | Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 508. By Mechanical Means. Type B. (ii) Bitumen (S-65) Rate as per SOR 2025-2026, 5.11, Type B (ii)/508 |
| 176 | Kilometer StoneReinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause1703ii) Ordinary Kilometer Stone (Precast) Rate as per SOR 2025-2026, 10.10, (ii) / 1703 |
| 177 | Kilometer StoneReinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause1703iii) 200 m stone (precast) Rate as per SOR 2025-2026, 10.10, (iii) / 1703 |
| 178 | Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801ii) 600mm equilateral triangle Rate as per SOR 2025-2026, 10.2, A, I, (ii) / 801 |
| 179 | Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801iii) 600mm circular Rate as per SOR 2025-2026, 10.2, A, I, (iii) / 801 |
| 180 | Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801v) 600mm x 450mm rectangular Rate as per SOR 2025-2026, 10.2, A, I, (v) / 801 |
| 181 | Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801vi) 600mm x 600mm square Rate as per SOR 2025-2026, 10.2, A, I, (vi) / 801 |
| 182 | Road Marking with Hot Applied Thermoplastic Compound withReflectorising Glass Beads on Bituminous SurfaceProviding and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specificationsRate as per SOR 2025-2026, 16.34 |
| 183 | PMGSY Title informatory sign board Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will primer and two coats of epoxy paint as per drawing Clause 1710 and Annexure 1700.1. Rate as per SOR 2025-2026, 10.16 |
| 184 | Providing and fixing of typical Maintenance Information BoardProviding and fixing of typical Citizens Information Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 4 nos. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 Rate as per SOR 2025-2026, 10.16 |
| 185 | Providing and Fixing PMGSY Logo BoardProviding and fixing of typical Logo Board with PMGSY Logo as per MORD specifications and drawing. 1 nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 1 nos. steel plate will be welded horizontally with 1 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The 1 no steel plate will be welded vertically to 1 no. 75mm x 75mm of 12 |SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, borderetc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 Rate as per SOR 2025-2026, 10.16 |
| 186 | Providing and Fixing Citizens Information BoardProviding and fixing of typical Citizens Information Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 4 nos. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 Rate as per SOR 2025-2026, 10.16 |
| 187 | Cross Drainage WorksEarthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.Rate as per SOR 2025-2026, 11.1 |
| 188 | PCC M10(1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawing and technical specification clause 1109 Rate as per SOR 2025-2026, 9.7 |
| 189 | Laying (First Class) bedding on well compacted approved granular material as per Clause 1105 (ii)Rate as per SOR 2025-2026, 9.2 |
| 190 | Brick masonry work in cement mortar in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 600, 1202 & 1203. (ii) Brick masonry in 1:4 cement mortar Rate as per SOR 2025-2026, 9.8 |
| 191 | Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204Rate as per SOR 2025-2026, 9.11 |
| 192 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.(B) 1000 mm diaRate as per SOR 2025-2026, 9.3 |
| 193 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. i) By Mechanical Means. a) In area of non-thorny jungle Rate as per SOR 2025-2026, 2.2, (ii), (a) |
| 194 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5(i) Private Land Rate as per SOR 2025-2026, 3.4 / 301.5 |
| 195 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.(i) Private LandFor ShoulderRate as per SOR 2025-2026, 3.14 / 303.1 |
| 196 | Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.(A) By Mix in Place Methodii) For Grading II MaterialQty. as per Statement No. - 2Rate as per SOR 2025-2026, 4.1 / 401 |
| 197 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. 1) Grading-II. (A) By By Manuall Means Rate as per SOR 2025-2026, 4.7 / 405 |
| 198 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 3 as per Technical Specification Clause 405. 1) Grading-III. (A) By By Manuall Means Rate as per SOR 2025-2026, 4.7 / 406 |
| 199 | Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502.(i) Low PorosityQty. as per Statement No. - 2Rate as per SOR 2025-2026, 5.1 / 502 |
| 200 | Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.Qty. as per Statement No. - 2Rate as per SOR 2025-2026, 5.2 / 503 |
| 201 | Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 508. By Mechanical Means. Type B. (ii) Bitumen (S-65) Rate as per SOR 2025-2026, 5.11, Type B (ii)/508 |
| 202 | Kilometer StoneReinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause1703ii) Ordinary Kilometer Stone (Precast) Rate as per SOR 2025-2026, 10.10, (ii) / 1703 |
| 203 | Kilometer StoneReinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause1703iii) 200 m stone (precast) Rate as per SOR 2025-2026, 10.10, (iii) / 1703 |
| 204 | Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801ii) 600mm equilateral triangle Rate as per SOR 2025-2026, 10.2, A, I, (ii) / 801 |
| 205 | Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801iii) 600mm circular Rate as per SOR 2025-2026, 10.2, A, I, (iii) / 801 |
| 206 | Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801v) 600mm x 450mm rectangular Rate as per SOR 2025-2026, 10.2, A, I, (v) / 801 |
| 207 | Road Marking with Hot Applied Thermoplastic Compound withReflectorising Glass Beads on Bituminous SurfaceProviding and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specificationsRate as per SOR 2025-2026, 16.34 |
| 208 | PMGSY Title informatory sign board Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will primer and two coats of epoxy paint as per drawing Clause 1710 and Annexure 1700.1. Rate as per SOR 2025-2026, 10.16 |
| 209 | Providing and fixing of typical Maintenance Information BoardProviding and fixing of typical Citizens Information Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 4 nos. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 Rate as per SOR 2025-2026, 10.16 |
| 210 | Providing and Fixing PMGSY Logo BoardProviding and fixing of typical Logo Board with PMGSY Logo as per MORD specifications and drawing. 1 nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 1 nos. steel plate will be welded horizontally with 1 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The 1 no steel plate will be welded vertically to 1 no. 75mm x 75mm of 12 |SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, borderetc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 Rate as per SOR 2025-2026, 10.16 |
| 211 | Providing and Fixing Citizens Information BoardProviding and fixing of typical Citizens Information Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 4 nos. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 Rate as per SOR 2025-2026, 10.16 |
| 212 | Cross Drainage WorksEarthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.Rate as per SOR 2025-2026, 11.1 |
| 213 | PCC M10(1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawing and technical specification clause 1109 Rate as per SOR 2025-2026, 9.7 |
| 214 | Laying (First Class) bedding on well compacted approved granular material as per Clause 1105 (ii)Rate as per SOR 2025-2026, 9.2 |
| 215 | Brick masonry work in cement mortar in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 600, 1202 & 1203. (ii) Brick masonry in 1:4 cement mortar Rate as per SOR 2025-2026, 9.8 |
| 216 | Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204Rate as per SOR 2025-2026, 9.11 |
| 217 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.(B) 1000 mm diaRate as per SOR 2025-2026, 9.3 |
| 218 | Drainage WorksEarthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Rate as per SOR 2025-2026, 11.1 |
| 219 | Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109II.With natural GravelP.C.C Grade M 10 Rate as per SOR 2025-2026, 11.4 |
| 220 | Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204III Random rubble masonryIn 1:5 cement mortar Rate as per SOR 2025-2026, 12.4 |
| 221 | Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204 Rate as per SOR 2025-2026, 12.3 |
| 222 | Providing PCC M-20 architectural coping on the top of wing wall, return wall etc.complete as per drawing and technical specification Clauses 615, 710 and1204.3.11 Rate as per SOR 2025-2026, 12.13 |
| 223 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. i) By Mechanical Means. a) In area of non-thorny jungle Rate as per SOR 2025-2026, 2.2, (ii), (a) |
| 224 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5(i) Private Land Rate as per SOR 2025-2026, 3.4 / 301.5 |
| 225 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.(i) Private LandFor ShoulderRate as per SOR 2025-2026, 3.14 / 303.1 |
| 226 | Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.(A) By Mix in Place Methodii) For Grading II MaterialQty. as per Statement No. - 2Rate as per SOR 2025-2026, 4.1 / 401 |
| 227 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. 1) Grading-II. (A) By By Manuall Means Rate as per SOR 2025-2026, 4.7 / 405 |
| 228 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 3 as per Technical Specification Clause 405. 1) Grading-III. (A) By By Manuall Means Rate as per SOR 2025-2026, 4.7 / 406 |
| 229 | Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502.(i) Low PorosityQty. as per Statement No. - 2Rate as per SOR 2025-2026, 5.1 / 502 |
| 230 | Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.Qty. as per Statement No. - 2Rate as per SOR 2025-2026, 5.2 / 503 |
| 231 | Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 508. By Mechanical Means. Type B. (ii) Bitumen (S-65) Rate as per SOR 2025-2026, 5.11, Type B (ii)/508 |
| 232 | Kilometer StoneReinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause1703ii) Ordinary Kilometer Stone (Precast) Rate as per SOR 2025-2026, 10.10, (ii) / 1703 |
| 233 | Kilometer StoneReinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause1703iii) 200 m stone (precast) Rate as per SOR 2025-2026, 10.10, (iii) / 1703 |
| 234 | Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801ii) 600mm equilateral triangle Rate as per SOR 2025-2026, 10.2, A, I, (ii) / 801 |
| 235 | Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801iii) 600mm circular Rate as per SOR 2025-2026, 10.2, A, I, (iii) / 801 |
| 236 | Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801v) 600mm x 450mm rectangular Rate as per SOR 2025-2026, 10.2, A, I, (v) / 801 |
| 237 | Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801vi) 600mm x 600mm square Rate as per SOR 2025-2026, 10.2, A, I, (vi) / 801 |
| 238 | Road Marking with Hot Applied Thermoplastic Compound withReflectorising Glass Beads on Bituminous SurfaceProviding and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specificationsRate as per SOR 2025-2026, 16.34 |
| 239 | PMGSY Title informatory sign board Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will primer and two coats of epoxy paint as per drawing Clause 1710 and Annexure 1700.1. Rate as per SOR 2025-2026, 10.16 |
| 240 | Providing and fixing of typical Maintenance Information BoardProviding and fixing of typical Citizens Information Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 4 nos. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 Rate as per SOR 2025-2026, 10.16 |
| 241 | Providing and Fixing PMGSY Logo BoardProviding and fixing of typical Logo Board with PMGSY Logo as per MORD specifications and drawing. 1 nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 1 nos. steel plate will be welded horizontally with 1 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The 1 no steel plate will be welded vertically to 1 no. 75mm x 75mm of 12 |SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, borderetc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 Rate as per SOR 2025-2026, 10.16 |
| 242 | Providing and Fixing Citizens Information BoardProviding and fixing of typical Citizens Information Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 4 nos. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 Rate as per SOR 2025-2026, 10.16 |
| 243 | Cross Drainage WorksEarthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.Rate as per SOR 2025-2026, 11.1 |
| 244 | PCC M10(1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawing and technical specification clause 1109 Rate as per SOR 2025-2026, 9.7 |
| 245 | Laying (First Class) bedding on well compacted approved granular material as per Clause 1105 (ii)Rate as per SOR 2025-2026, 9.2 |
| 246 | Brick masonry work in cement mortar in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 600, 1202 & 1203. (ii) Brick masonry in 1:4 cement mortar Rate as per SOR 2025-2026, 9.8 |
| 247 | Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204Rate as per SOR 2025-2026, 9.11 |
| 248 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.(B) 1000 mm diaRate as per SOR 2025-2026, 9.3 |
| 249 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. i) By Mechanical Means. a) In area of non-thorny jungle Rate as per SOR 2025-2026, 2.2, (ii), (a) |
| 250 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5(i) Private Land Rate as per SOR 2025-2026, 3.4 / 301.5 |
| 251 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.(i) Private LandFor ShoulderRate as per SOR 2025-2026, 3.14 / 303.1 |
| 252 | Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.(A) By Mix in Place Methodii) For Grading II MaterialQty. as per Statement No. - 2Rate as per SOR 2025-2026, 4.1 / 401 |
| 253 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. 1) Grading-II. (A) By By Manuall Means Rate as per SOR 2025-2026, 4.7 / 405 |
| 254 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 3 as per Technical Specification Clause 405. 1) Grading-III. (A) By By Manuall Means Rate as per SOR 2025-2026, 4.7 / 406 |
| 255 | Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502.(i) Low PorosityQty. as per Statement No. - 2Rate as per SOR 2025-2026, 5.1 / 502 |
| 256 | Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.Qty. as per Statement No. - 2Rate as per SOR 2025-2026, 5.2 / 503 |
| 257 | Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 508. By Mechanical Means. Type B. (ii) Bitumen (S-65) Rate as per SOR 2025-2026, 5.11, Type B (ii)/508 |
| 258 | Kilometer StoneReinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause1703ii) Ordinary Kilometer Stone (Precast) Rate as per SOR 2025-2026, 10.10, (ii) / 1703 |
| 259 | Kilometer StoneReinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause1703iii) 200 m stone (precast) Rate as per SOR 2025-2026, 10.10, (iii) / 1703 |
| 260 | Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801ii) 600mm equilateral triangle Rate as per SOR 2025-2026, 10.2, A, I, (ii) / 801 |
| 261 | Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801iii) 600mm circular Rate as per SOR 2025-2026, 10.2, A, I, (iii) / 801 |
| 262 | Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801v) 600mm x 450mm rectangular Rate as per SOR 2025-2026, 10.2, A, I, (v) / 801 |
| 263 | Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801vi) 600mm x 600mm square Rate as per SOR 2025-2026, 10.2, A, I, (vi) / 801 |
| 264 | Road Marking with Hot Applied Thermoplastic Compound withReflectorising Glass Beads on Bituminous SurfaceProviding and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specificationsRate as per SOR 2025-2026, 16.34 |
| 265 | PMGSY Title informatory sign board Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will primer and two coats of epoxy paint as per drawing Clause 1710 and Annexure 1700.1. Rate as per SOR 2025-2026, 10.16 |
| 266 | Providing and fixing of typical Maintenance Information BoardProviding and fixing of typical Citizens Information Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 4 nos. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 Rate as per SOR 2025-2026, 10.16 |
| 267 | Providing and Fixing PMGSY Logo BoardProviding and fixing of typical Logo Board with PMGSY Logo as per MORD specifications and drawing. 1 nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 1 nos. steel plate will be welded horizontally with 1 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The 1 no steel plate will be welded vertically to 1 no. 75mm x 75mm of 12 |SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, borderetc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 Rate as per SOR 2025-2026, 10.16 |
| 268 | Providing and Fixing Citizens Information BoardProviding and fixing of typical Citizens Information Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 4 nos. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 Rate as per SOR 2025-2026, 10.16 |
| 269 | Cross Drainage WorksEarthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.Rate as per SOR 2025-2026, 11.1 |
| 270 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203II. With natural Graveli.Nominal mix 1:2.5:5 Rate as per SOR 2025-2026, 11.4 |
| 271 | Plain/reinforced cement concrete in substructure complete as per drawings andtechnical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204 C. RCC Grade M20i Height upto 5m Rate as per SOR 2025-2026, 12.5 |
| 272 | Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203. C)Random Rubble Masonryi.In 1:3 cement mortar Rate as per SOR 2025-2026, 11.6 |
| 273 | Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204(C)Random rubble masonryi.In 1:3 cement mortar Rate as per SOR 2025-2026, 12.4 |
| 274 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 Rate as per SOR 2025-2026, 12.9 |
| 275 | Supplying, fitting and placing TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-550N/sqmm (Fe-550 D) from Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal steel/ Shyam steel/ RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 Rate as per SOR 2025-2026, 12.6 |
| 276 | Drainage spouts complete as per drawing and technical specifications Clause1209 Rate as per SOR 2025-2026, 13.10 |
| 277 | Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 Rate as per SOR 2025-2026, 13.6 |
| 278 | Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Rate as per SOR 2025-2026, 14.10 |
| 279 | Sand Filling in Foundation Trenches as per drawing and technical specification Clause 1108 Rate as per SOR 2025-2026, 11.2 |
| 280 | Providing PCC Grade M15 for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Rate as per SOR 2025-2026, 11.4, II |
| 281 | Providing Reinforced cement RCC GRADE M-25 concrete in box cell complete as per drawings and technical specification Clauses 802, 804,805, 806, 807, 1202 and 1204. Rate as per SOR 2025-2026, 12.5, D, (i) |
| 282 | Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 (Graular Materials) Rate as per SOR 2025-2026, 12.10 |
| 283 | Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8 Rate as per SOR 2025-2026, 12.11 |
| 284 | Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing less than 25 kg laid dry complete as per drawing and technical specifications Clause 1301. Rate as per SOR 2025-2026, 14.1 Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
| 9 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail