| 1 | Taking down carefully unserviiceable copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc. |
| 2 | Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse) |
| 3 | Material and Labour for point wiring using approved colour coding as per IS ,with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty, Steel conduit with all fittings, accessories, PVC junction boxes etc fixed to walls/ceilings with and including concealed GI metal boxes 1.2 mm thick,(18 Guage) 50mm deep, with earth dolly, covered with modular white cover plate & frame suitable for mounting modular switches, sockets, regulators etc and also including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed for the One light point controlled by one, one way switch 6 Amps complete all as specified and as directed |
| 4 | Description all as per Item No 3 here-in before but using 2.5 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade, for one 6 pin socket outlet plug point, 6 Amps independent including necessary running of 2.5 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed |
| 5 | Material and Labour for point wiring using approved colour coding as per IS ,with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty, PVC casing caping with all fittings, accessories, PVC junction boxes etc fixed to walls/ceilings with and including concealed GI metal boxes 1.2 mm thick,(18 Guage) 50mm deep, with earth dolly, covered with modular white cover plate & frame suitable for mounting modular switches, sockets, regulators etc and also including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed for the One light point controlled by one, one way switch 6 Amps complete all as specified and as directed |
| 6 | Description all as per Item No 3 here-in before but using 2.5 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade, for one 6 pin socket outlet plug point, 6 Amps independent including necessary running of 2.5 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed. |
| 7 | M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 1.5 Sqmm nominal area and drawing into steel conduit and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed.Note- Three run of 1.5 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed. |
| 8 | M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 2.5 Sqmm nominal area and drawing into steel conduit and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 2.5Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed.Note- Three run of 2.5 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed. |
| 9 | M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 4 Sqmm nominal area and drawing into steel conduit and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 4 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed.Note- Three run of 4 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed. |
| 10 | M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 6 Sqmm nominal area and drawing into steel conduit and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 6 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed.Note- Three run of 6 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed. |
| 11 | M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 1.5 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty conduit and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed.Note- Three run of 1.5 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed. |
| 12 | M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 4 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty conduit and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 4 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed.Note- Three run of 2.5 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed. |
| 13 | M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 4 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty conduit and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 4 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed.Note- Three run of 4 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed. |
| 14 | M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 6 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty conduit and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 6 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed.Note- Three run of 6 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed. |
| 15 | Excavation in trenches n.exc 1.5 m wide and n. exc 1.5 m in depth and getting out in soft/loose soil for removing/laying of cables complete all as specified and as directed by Engineer-in-charge. |
| 16 | Returning, filling in including spreading , leveling , watering and well ramming in layers n.exc 25 cm with soil complete all as specified and as directed by the Engineer-in- Charge. |
| 17 | Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge. |
| 18 | Material & Labour sand filling under floors or in foundation including watering & consolidation for cable cushioning all as specified and directed |
| 19 | Supply and laying DWC HDPE pipes of pressure rating 6 Kg/Cm sq of size 32 mm laid in trenches complete all as specified and directed. |
| 20 | Supply and laying DWC HDPE pipes of pressure rating 6 Kg/Cm sq of size 40 mm laid in trenches complete all as specified and directed. |
| 21 | Supplying and laying unreinforced precast concrete cable cover class LV type 1, flat, size 250 x 150 x 40 mm complete all as specified and directed by the Engineer - in - charge. |
| 22 | Supply and fixing, install, test and commissioning of LT Feeder pillar box indoor type totally enclosed with only front opening hinged doors with canopy sloped top projected and raised platform of suitable sizes weather dust vermin proof IP-54 protection CPRI approved, factory fabricated, cubical panel free standing type, made out of 2.00 mm thick CRCA sheet with locking arragement, factory made powder coated as approved colour, copper bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 300 Amps rating capacity RYBN insulated with sleeved insulation complete with multifunctional meter LED type by showing Amps, volts, frequency etc along with suitable size of CT on outgoing, indicating lamp RYB , complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going cables as per required sizes, PCC platform made out of 1:2:4 type B1 and pedestal of 30 cm height from GL with suitable nut, bolts, washers etc, all as specified and directed for suitable to accomodate the following items including supply and fix following items and all as specified and directed by dismantling exisiting unserviceable LT panel complete with Make of LT Panel-L&T/Legrand/HPLLoc: Fire brigade |
| 23 | Incoming:MCCB 4 pole 250 Amp with breaking capacity 32 KA adjustable type with exended terminals -01 Nos Make: Legrand/Schneider/siemens/L&T |
| 24 | Outgoing:(a) MCCB 4 pole 100 Amps with breaking capacity 32 KA adjustable type with extended terminals- 04 No Make: Legrand/Schneider/siemens/L&T |
| 25 | (b) MCCB 4 pole 63 Amps with breaking capacity 32 KA adjustable type with extended terminals- 03 No's Make: Legrand/Schneider/siemens |
| 26 | (c) MCB TPN 40 Amps,breaking capacity 16 KA -02 Nos |
| 27 | (d) MCB SPN 32 Amps,breaking capacity 10 KA -03 Nos |
| 28 | (e) Current Transformers-03 Nos |
| 29 | (f) Multi functional Meter-01 |
| 30 | (g) LED RYB indiacator lamps-01/Set |
| 31 | Note:- The panel must have separate Bus bar chamber, cable chamber and proper spacing must be maintained between each chamber of panel as per IS. |
| 32 | Supply and fixing, install, test and commissioning of LT Feeder pillar box indoor type totally enclosed with front and rear opening hinged doors with canopy sloped top projected and raised platform of suitable sizes weather dust vermin proof made out of 3.15 mm thick CRCA sheet, factory made powder coated as approved colour, aluminum bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 160 Amps rating capacity RYBN insulated with sleeved insulation complete with multifunctional meter LED type by showing Amps, volts, frequency etc along with suitable size of CT on outgoing, indicating lamp RYB , complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going cables as per required sizes, PCC platform made out of 1:2:4 type B1 and pedestal of 30 cm height from GL with suitable nut, bolts, washers etc., all as specified and directed for suitable to accomodate the following items including supply and fix following items and all as specified and directed by dismantling exisiting unserviceable LT panel complete with LT panel made by CPRI approved manufacturer confiring to IS:-8623-1993.Note :- Minimum panel depth should be 400 mm.Location: Panel inside at Store house No 31 [MO MB) Ghatkopar] |
| 33 | Incoming:- MCCB 4 pole 400 Amps with breaking capacity 35KA adjustable type with extended terminals- 01No's Make: Legrand/Schneider/siemens/L&T |
| 34 | Outgoing:-(a) MCCB 4 pole 100 Amps with breaking capacity 32KA adjustable type with extended terminals- 02 No's Legrand/Schneider/siemens/L&T |
| 35 | (b) MCB TPN 40 Amps with breaking capacity 10KA - 01 No's Make: Legrand/Schneider/siemens/L&T |
| 36 | (c) MCB SPN 40 Amps with breaking capacity 16KA adjustable type with extended terminals- 02 No's Make: Legrand/Schneider/siemens/L&T |
| 37 | (d) MCCB 4 pole 63 Amps with breaking capacity 32 KA adjustable type with extended terminals- 04 No's Make: Legrand/Schneider/siemen |
| 38 | (e) Digital AMMETER WITH C.T -03 Nos |
| 39 | (f) Digital Voltmeter- 01 |
| 40 | (g) LED RYB indiacator lamps-01/Set |
| 41 | (h) Single phase preventor-01 Set |
| 42 | Note-: The panel must have separate Bus bar chamber, cable chamber and proper spacing must be maintained between each chamber of panel as per IS . |
| 43 | Taking up of unsv LT XLPE cable of any size and connected items complete all as specified and directed by Engr-in-Charge. |
| 44 | Supply and laying in repairs cable LT XLPE insulated and screened PVC bedded, galvanised steel strip armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade complete all as specified and directed by Engineer in charge for the size10 Sqmm 4 Core including taking up existing u/s LT cable. |
| 45 | All as per item no 25 above but 16 Sqmm 4 Core. |
| 46 | All as per item no 25 above but 25 Sqmm 3.5 Core. |
| 47 | All as per item no 25 above but 95 Sqmm 3.5 Core. |
| 48 | All as per item no 25 above but 120 Sqmm 3.5 Core. |
| 49 | All as per item no 25 above but 150 Sqmm 3.5 Core. |
| 50 | All as per item no 25 above but 185 Sqmm 3.5 Core. |
| 51 | All as per item no 25 above but 240 Sqmm 3.5 Core. Please Enable Macros to View BoQ information |
| 52 | All as per item no 25 above but 240 Sqmm 3.5 Core. Please Enable Macros to View BoQ information |