| 1 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed. |
| 2 | Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed. |
| 3 | Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified. |
| 4 | Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed .Note :- Punned thickness shall only be considered for payment |
| 5 | Supply and laying reinforced precast concrete cable cover, class LV, type 2 flat, size 300mm x 180mm x 40mm |
| 6 | Boring/Drilling ( horizontally) manually under existing road ( maximum 10 M in width) suitable for passing GI tubing of 40 to 80 mm bore complete all as specified. |
| 7 | S & F GI tubing 'Light' grade 40 MM for cable protection fixed in poles/walls/laid under roads/crossing etc incl taking out the rusted pipes of following sizes, complete all as specified and directed. |
| 8 | - ditto - but size 50 mm bore dia |
| 9 | Labour for taking out and Laying only ( in replacement), jointing and testing LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 10 sqmm cross sectional area, 3 core , complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection PCC cover/ tiles/ block and pipe shall be measured and paid separately under appropriate items. |
| 10 | - do - but of size 16 Sqmm 3 core. |
| 11 | - do - but of size 10 Sqmm 4 core. |
| 12 | - do - but of size 16 Sqmm 4 core. |
| 13 | - do - but of size 25 Sqmm 4 core. |
| 14 | Supplying and fixing in repair flat twin core ,2.5 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified. |
| 15 | M & L for taking down and Supplying, transporting, erecting and fixing Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed. |
| 16 | Dismantling and removing existing unsv street light/ flood light MH/HPSV fittings of any type and any capacity from street light poles any hieght and high mast light pole after disconnecteing of electrical connection complete all as specified and directed. |
| 17 | Supply, fixing, connecting and testing energy saving LED street light fittings 35 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed. |
| 18 | Supply, fixing, connecting and testing energy saving LED street light fittings of 60 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed |
| 19 | Supply, fixing, connecting and testing energy saving LED street light fittings of 70 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed |
| 20 | Supply, fixing, connecting and testing energy saving LED street light fittings of 90 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed. |
| 21 | Supply, fixing, connecting and testing energy efficient LED flood light fittings of 70 Watt pressure die cast aluminium housing and IP66 protection complete all as specified and directed. |
| 22 | Supply, fixing, connecting and testing energy efficient LED flood light fittings of 100 Watt pressure die cast aluminium housing and IP66 protection complete all as specified and directed. |
| 23 | Supply, fixing, connecting and testing energy efficient LED flood light fittings of 120 Watt pressure die cast aluminium housing and IP66 protection complete all as specified and directed. |
| 24 | Supply and fixing post top lantern LED type 20 watt 230 volts AC outdoor type with decorative post top for 360 degree indiret light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete |
| 25 | Supply and fixing post top lantern LED type 40 watt 230 volts AC outdoor type with decorative post top for 360 degree indiret light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete |
| 26 | S&F in replacement GI bracket for street light fittings fabricated with GI tubing 40mm dia 'light grade' upto 1.5m long and bending to angle of 120 degree including mild steel clamp of suitable size with two coat aluminium paint suitable for fixing on PCC/steel poles complete all as specified and directed. |
| 27 | Maintenance and repair to existing street / perimeter security lights fittings / solar lights etc of any type / size/ wattage from date of work order / physically handing over site to contractor as nature the work is of urgent requirement keeping security of areas and any specifications, fittings / fixed of poles, buildings or watching towers of any heights, finding faults in LT feeder and light fittings, liasoning with connectioning sub station of MES, reporting to concerned JE E/M and Engr-in-Charge about the faults complete manpower for repair & refixing including rectifying the same by replacing defective spare parts as per direction by concerned JE E/M and Engr-in-Charge at various location complete all as specified and directed.Note :- 1. Spare parts of light fitting / fitting shall be measured and paid separately under relevant items of Schedule 'A' as supply only as per requirement for repair / replacement however providing manpower on daily basis as quoted above. |
| 28 | Supply in replacement LED street light driver of capacity 25 to 40 watt, make of LED driver as per suitable light fitting of make and type as per sample complete all as specified and directed |
| 29 | Supply in replacement LED street light driver of capacity 45 to 60 watt, make of LED driver as per suitable light fitting of make and type as per sample complete all as specified and directed |
| 30 | Supply in replacement LED street light driver of capacity 70 to 100 watt, make of LED driver as per suitable light fitting of make and type as per sample complete all as specified and directed |
| 31 | Supply and fixing in replacement of LED Bollard 10 Watt LED fitting energy saving long life aesthetically designed metal body cone bollard with required nut, bolt, washer all as specified and directed of Jaquar Cat Part No OBL-GRY-LBLDCON010XW or its equivalent. |
| 32 | Supply and fixing in replacement of garden light ground burial type fitting LED 12 watt complete set including LED lamp integrated, of make Corompton Cat Part No HPLLEDG11260 or its equivaalent. |
| 33 | Supply and fixing SMC junction box with bus bar suitable for connection (Incoming / outgoing) of three phase & neutral and 1 x MCB SP on the LT electric pole of rectangular or circular shape as existing at a height of in between 1-1.4 mtr with nut, bolt, washer etc. (Make : Syntex or equivalent). |
| 34 | Supply & fixing in replacement automatic street light timer pannel 12 KW/ 40 Amp switch using Infrared Sensor based for automatic switching of street lights based on LUX level of natural light. Required illuminance for switching ON is < 30 Lux and for switching OFF > 10 Lux level. The sensor (nature switch) alongwith suitable power contactors, Input (supply) MCB and output (load) MCBs support terminals should be enclosed in pole/wall mountable encloser made of rust proof, termite proof and FR graded SMC juncation box conforming to IP-54 degree of ingress three phase 8 KW lightening load capacity including mounting bracket cable glands openable doors with lock complete all as specified and directed by EIC. |
| 35 | Taking down Old unsv LED Street lights of any size and supply & fixing LED lights of “Lithium based energy efficient Integrated solar street light of 40Watt” in single FRP body with duly polyurethane coating (Camouflage color), encases with monocrystalline solar PV Panel of 90/95Wp , lithium battery 11.1/12.8V, 44.0AH with inbuilt BMS, IP 65, high brightness W-LED(160-180lm/watt) lamp with aluminum reflector for better light distribution , CRI >70, Color temperature 5700K - 6500K, microcontroller based charge controller cum driver, automatic dimming function (first four hours at full brightness & rest of the time at lower light level with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 10C to (+)55C, weight not more than 18-20kg with adjustable MS clamp suitable for pole/wall mounting etc complete as required. Protections: Short Circuit, overload, Reverse polarity and battery protections. Firm should provide Vital Parameters Test report from NABL accredited lab and should be of made in India with CE & ROHS compliant. (Make : AXXON or equivalent) |
| 36 | Taking Down old LED Street lights and Supply of “Lithium based Energy Efficient Integrated Solar Decorative Street Light 32Watt” in Single FRP body, encases with Flexible Mono-crystalline Solar PV Panel of 65Wp , Lithium Battery 11.1/12.8V, 33.0AH with inbuilt BMS, IP 65, High brightness W-LED (160-180lm/watt) lamp with optical Lens for better light distribution , CRI >80, Color Temperature 5700K-6500K. Microcontroller based charge controller cum driver, automatic dimming function ( first four hours at full brightness & rest of the time at lower light level with PIR Motion Sensor), Dusk to Dawn Operation, LUX Output 25-35 (from 5/6 mtr height),working temperature: (-) 10C to (+)55C, weight 08-10kg etc complete as required. Protections: Short Circuit, overload, Reverse polarity and battery protections.(Make: AXXON or equivalent). |
| 37 | Material and Labour for renewal of plate earthing for LT panel with galvanised mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate electrode at one end and connected to metallic bodies of HT/LT equipments etc at the other, earth strip encased in and including 40mm bore GI medium grade pipe with all fittings from top of electrode to body of equipment fixed with and including 40 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-O using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work , etc.complete all as specified and shown in electrical plate No 3 of SSR Pt-I. |
| 38 | Taking down carefully from overhead pole and material & labour for repair of old unsv solar light of 40 Watt capacity with replacment of the follwing accessories and refixing after repairing at the pole as per direction by Engr-in-Charge : |
| 39 | (a) Lithium Battery 11.1V/39.6 Ah suitable for 40 Watt solar light with BMS circuit and other necessary wires and connectors. |
| 40 | (b) Motion sensor Cap as per existing |
| 41 | (c) Solar charge controller 15 Amp with protection circuits for 40 to 60 Watt Solar Light |
| 42 | (d) PIR motion sensor 170uA for 12 to 60 Watt solar light standard detection 5m |
| 43 | (e) Rocker switch 10Amp for solar lights |
| 44 | Taking down carefully from overhead pole and material & labour for repair of old unsv solar light of 32 Watt capacity with replacment of the follwing accessories and refixing after repairing at the pole as per direction by Engr-in-Charge : |
| 45 | (a) Lithium Battery 11.1V/33 Ah suitable for 32 Watt solar light with BMS circuit and other necessary wires and connectors. |
| 46 | (b) Motion sensor Cap as per existing |
| 47 | (c) Solar charge controller 15 Amp with protection circuits for 32 Watt Solar Light |
| 48 | (d) PIR motion sensor 170uA for 12 to 60 Watt solar light standard detection 5m |
| 49 | (e) Rocker switch 10Amp for solar lights |
| 50 | Taking down carefully from overhead pole and material & labour for repair of old unsv solar light of 20/24 Watt capacity with replacment of the follwing accessories and refixing after repairing at the pole as per direction by Engr-in-Charge: |
| 51 | (a) Lithium Battery 11.1V/28.6 Ah suitable for 20/24 Watt solar light with BMS circuit and other necessary wires and connectors. |
| 52 | (b) Motion sensor Cap as per existing |
| 53 | (c) Solar charge controller 15 Amp with protection circuits for 20/24 Watt Solar Light |
| 54 | (d) PIR motion sensor 170uA for 12 to 60 Watt solar light standard detection 5m |
| 55 | (e) Rocker switch 10Amp for solar lights |
| 56 | Material and Labour for renewal of plate earthing for LT panel withgalvanised steel earth plate electrode 60cm X 60cm X 6mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or stee all as shown in electrcal plate No 3 of SSR Part-I connected to continious earth wire or main switch board/ panel etc all as specified or indicated and testing on completion including provision of earth wire protection by 15 mm dia,light grade GI pipe and watering pipe shall be 20 mm bore medium grade GI pipe including excavation & earth work, PCC pit with RCC cover, charcoal, salt, funnel, GI wire and protection pipe upto 7.5 mtr complete all as specified and directed. |
| 57 | Supply and Installation Maintenance free earthing: Earth pits shall be maintenance free. Earth electrode shall be High tensile low carbon steel rod of 3 Mts length & 25 mm dia with 250 micron ( average ) molecularly bonded copper on the outer surface. Back-fill compound should strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE: 80 standards. Back-fill compound should be electronically conductive (Like in metals) and should not depend on moisture for conduction JEF ECO SAFE compound shall be supplied in 50 Pound Bag ( 22.5 kg Bag. (1Bag required per earth pit). Back-fill compound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. Back-fill compound shall not be mixed with any soil while pouring in the bore hole. Test Certificate for Back-fill compound should be submitted. Earth termination clamp shall be of 25 mm OD SS Clamp Both Side for terminating both round and flat conductors of required size. Heavy duty weather proof Polyethylene Earth Pit Chamber with following dimensions: 254 mm dia (top), 330 mm dia (bottom) & 260 mm (height) including 40 x 6mm flat iron clamps, bolts, nuts and washer complete all specified and directed. Material and Labour for Testing of water from approved Govt lab samples collected from pump house No-01 at main Gate as per norms of WHO and submission of test reports to the entire satisfaction of Engineer-in-Charge, the test report includes following parameters:- PH value, TDS(mg/l), Hardness (as CaCO3) (mg/l), Fluoride (mg/l), Chloride (mg/l),Turbidity (NTU), E.Coli (cfu), Free residual Chlorine Please Enable Macros to View BoQ information |