| 1 | Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 185 Sqmm 3.5 core complete all as specified and as directed. |
| 2 | Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 core complete all as specified and as directed. |
| 3 | Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 90 Sqmm 3.5 core complete all as specified and as directed. |
| 4 | Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core complete all as specified and as directed.. |
| 5 | Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core complete all as specified and as directed. |
| 6 | Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core complete all as specified and as directed.. |
| 7 | Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 core complete all as specified and as directed. |
| 8 | Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 2 core complete all as specified and as directed. |
| 9 | Earthing complete with galvanized steel earth plate electrode 600x600x6mm surrounded by mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less 2.25mtr below ground level with top edge of earth plate at a depth of not less than 1.50mtrs below ground level connected with and including 32x6mm galvanized iron strip as earthing lead by means of bolts, nuts, check nuts and washers made out of galvanized iron, 20mm dia medium grade GI pipes for watering with funnel, wire mesh and 40mm GI light grade protection pipe for GI strip and including necessary excavation, earth work, PCC 1:3:6 type C-2 concrete pit and RCC pit cover charcoal and common salt filling in alternate layers complete all as specified and directed by Engineer-in-Charge on electrical plate no-3 of SSR Par-I of 2009. NOTE :- (i) If desirable earthing result not found re done earthing without any extra charge until get required earth resistance. (ii) The result sheet of earthing may submit to sub division level by contractor. |
| 10 | Material and labour for cable route indicator made of cast iron plate circular type 10 cm dia duly marked Blue colour marked LT cabless arrows mark up side duly welded/nut, bolt with angle iron 45/45 equal size and 45 cm long duly grouted on fround with PCC (1:3:6) as in foundation & earth work excavation etc complete all as specified and as directred at site. |
| 11 | Supply, Installing testing and commissioning, weather, vermin proof LT Feeder pillar box of suitable size factory fabricated (Approved by CPRI) outdoor cubical/KIOSK type totally enclosed made out of 3.15 mm thick CRCA sheet with double door shutter with locking arrangement and mounted on MS channel of mim size 75 x 40mm suitable for operation on 3 phase, 4 wire , 415volts, AC supply system with hinged panel door (covers) on two sides with handle, bottom gland plate and locking arrangement consisting of sufficient no's of circular cable entry holes at bottom only with suitable PVC/Rubber bushes to prevent water/moisture inside the enclosure, required no's of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with strandard copper conductor FRLS wires of adequate size, duly powder coated internally & externally of approved shade with PCC foundation mounted on epoxy insulators with and constitute the following - Incomingi) Aluminium bus bar 200 Amps Capacity - 01 set (04 Nos) (ii) MCCB, 4 Pole, 415 V, 35KA, 200 Amps - 01 No Outgoing(a) MCCB 63 Amps , 4 pole, breaking capacity 25 KA,415 Volts – 04 Nos(b) Ammeter 0-400 Amps with selector switch -01 No(c) Voltmeter 0-500V With selector switch 01 No(d) Indicator lamps with control fush-01 set (Each set of three) |
| 12 | Supply, installation, testing and commissioning 3 phase and neutral, 415 volts out door type, factory made free standing, floor mounting, dust and vermin proof cubical type, LT Panel fabricated from 3.15 mm thick CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), fully compartmentalized design with 4 Nos of copper bus bar with colour code of 475 Amps capacity each and supply and fixing the followingIncoming(a) MCCB 315 Amps , 4 pole, ultimate breaking capacity 35 KA 415 Volts – 01 Nos Outgoing(a) MCCB 125.00 Amps , 4 pole, breaking capacity 25 KA, 415 Volts – 02 Nos (b) MCCB 100 Amps 4 Pole,25 KA, 415 V-01 Nos. (c) MCCB 63 Amps 4 Pole,25 KA, 415 V-01 Nos. (d) MCB 32 Amps 2 Pole,240 V-02 Nos.(For street Light) (e)Suitable size of Timer analog type for street light complete(f) Ammeter 0-400 Amps with selector switch -01 No( g ) Voltmeter 0-500V With selector switch 01 No(h ) Indicator lamps with control fush-01 set (Each set of three) |
| 13 | Supply, installation, testing and commissioning 3 phase and neutral, 415 volts out door type, factory made free standing, floor mounting, dust and vermin proof cubical type, LT Panel fabricated from 3.15 mm thick CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), fully compartmentalized design with 4 Nos of copper bus bar with colour code of 240 Amps capacity Incoming(a) MCCB 160 Amps , 4 pole, ultimate breaking capacity 25 KA 415 Volts – 01 Nos Outgoing(a) MCCB 40 Amps , 4 pole, breaking capacity 25 KA,415 Volts – 06 Nos (b) Ammeter 0-400 Amps with selector switch -01 No(c) Voltmeter 0-500V With selector switch 01 No |
| 14 | Supply and fix M S Box with Aluminum bus bar 32 Amp 1100 V complete of size 90mmX90mmX60mm of 3.15 mm thick sheet complete all as specified and as directed. |
| 15 | Excavation in trenches in soft/loose soil not exceeding 1.50 meter wide and not exceeding 1.5 meter in depth and not exceeding 10sqmm on plan and getting out complete all as specified and as directed. |
| 16 | Returning, filling in including spreding, levelling, watering and well ramming in layers not exceeding 25 cm thick each excavated soil in trenches after the pipes have been laid and tested completed as in soft/loose soil all as specified and as directed. |
| 17 | Removing of surplus soil/excavated material to a distance not exceeding 50meter and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 18 | Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 16205 & IS14930 (Part I and II) for protection of underground cable of size 40 mm outer dia with all fittings such as clamps. coupler etc laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified (excavation and earth work shall be measured and paid separately) |
| 19 | Description all as per item No- 18 above but of size 50mm OD |
| 20 | Description all as per item No- 18 above but of size 70mm OD |
| 21 | Description all as per item No- 18 above but of size 100mm OD |
| 22 | Description all as per item No- 18 above but of size 120mm OD |
| 23 | Description all as per item No- 18 above but of size 200mm OD |
| 24 | Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m. |
| 25 | Dismantling insulators any type, any size |
| 26 | Dismantling of ACSR or AAC conductors |
| 27 | Dismantling earth wire or copper conductor, service feeder or distributor span. |
| 28 | Dismantling stay assembly complete. |
| 29 | Boring of holes under road,pavement.hard standing by trenchless technology using ultra sounding technique and necessary machine for inserting GI Pipe upto 100 mm dia all as specified and as directed. Please Enable Macros to View BoQ information |