| 1 | Taking out old unserviceable LT UG Cable, 1100 volts grade of any type any size by disconnecting the connection carefully from both the ends complete all as specified and directed. |
| 2 | Supply Laying, testing and commissioning or fixing in Wall or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty ) with aluminium conductor cable of size 95 Sqmm 3.5 core , 1100 volts, grade jointed with suitable size thimbles and cable gland, complete all as specified and directed by Engr-in-Charge. |
| 3 | Supply Laying, testing and commissioning or fixing in Wall or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty ) with aluminium conductor cable of size 50 Sqmm 3.5 core , 1100 volts, grade jointed with suitable size thimbles and cable gland, complete all as specified and directed by Engr-in-Charge. |
| 4 | Supply Laying, testing and commissioning or fixing in Wall or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty ) with aluminium conductor cable of size 16 Sqmm 4 core , 1100 volts, grade jointed with suitable size thimbles and cable gland, complete all as specified and directed by Engr-in-charge. |
| 5 | Taking out old unserviceable HT UG Cable, 11000 volts grade of any type any size by disconnecting the connection carefully from both the ends complete all as specified and directed. |
| 6 | Supply , laying & testing XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 11000 volts grade earthed , laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 95 Sqmm 3 core nominal cross sectional area complete all as specified and directed as per IS-7098 (Part-I) |
| 7 | Supply and fix in repair/replacement cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 25 to 50 sq mm complete . Make- Recmay / Denson or equivalent . |
| 8 | Supply and fix in repair/replacement cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 70 to 150 sq mm complete .Make- Recmay / Denson or equivalent . |
| 9 | Supply and fix in repair/replacement cable jointing kit for 1.1 KV grade cable for \\"End Termination joint\\" complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 70 to 150 sq mm complete .Make- Recmay / Denson or equivalent. |
| 10 | Material & labour cable jointing kit for HT 11 KV (Earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50-95 sqmm including testing and commissioning & taking down old unserviceable cable jointing kit, complete all as specified & directed. |
| 11 | M&L Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armourend aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed. |
| 12 | M&L for searching fault location of HT/LT UG cable 11000/415 Volts laid in trenches/ducts with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with frequency distance calculator etc incl transportation of machinery. Excavation in any type of soil exposing the cable fault removal of deteriorated portion of the cable treating cable of any size including disconnecting and re-fixing cables with lugs as per directions of Engineer-in-charge. Please Enable Macros to View BoQ information |
| 13 | M&L for searching fault location of HT/LT UG cable 11000/415 Volts laid in trenches/ducts with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with frequency distance calculator etc incl transportation of machinery. Excavation in any type of soil exposing the cable fault removal of deteriorated portion of the cable treating cable of any size including disconnecting and re-fixing cables with lugs as per directions of Engineer-in-charge. Please Enable Macros to View BoQ information |