| 1 | Excavation in trenches (Manual), not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations of shafts, wells, cess pits, manholes, pipe line, cable in trenches etc., not exceeding 10 Sqm on plan and getting out in any type of soft including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed. |
| 2 | Returning, filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed. |
| 3 | Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed. |
| 4 | Material and labour for boring of holes (trenchless horizontal Directional Drilling) under road pavement, hard standing or any other situation by using trenchless boring mechanically or manual manpower by using manpower auger machine/spiral-bladed drill /Boki or any other means suitable for accommodate/inserting pipe upto 100mm bore in the drilled holes, including excavation, returning filling in the both ends working space including removal of surplus soil and making good the surface complete all as specified and as directed.Note ; (i) Only length of the road/hard standing/Pavement will be measured for payment and cost for excavation, returning filling and making good at both side of bore shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. (ii) Pipe shall be measured and paid separately) |
| 5 | Material and labour for PCC ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed |
| 6 | Material and labour for PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in foundation around the poles/stay, coping/Pedestal of pole, PCC block for grouting the MS legs etc including necessary form work, finishing the exposed surfaces of the concrete even & smooth without using extra cement, complete all as specified and as directed.(Note :- Volume of pole / strut / stays embedded in concrete shall be deducted for the purpose of payment) |
| 7 | Taking up and down old U/S LT UG cable (PVC/XLPE) of any size including protection cover from trenches/pipe/floor/walls, complete all as specified and as directed. |
| 8 | Supply and laying XLPE LT Cable of size 25 Sqmm, 4 core, 1100 Volt grade heavy duty with XLPE insulated, stranded aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip or wire and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and as directed. Note :- (i) Excavation, earth work, cutting of road/boring under road and protection pipe as required shall be measured & paid separately under appropriate item of this Schedule/BOQ.) |
| 9 | Supply and laying XLPE LT Cable of size 10 Sqmm, 4 core, 1100 Volt grade heavy duty with XLPE insulated, stranded aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip or wire and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and as directed. Note :- (i) Excavation, earth work, cutting of road/boring under road and protection pipe as required shall be measured & paid separately under appropriate item of this Schedule/BOQ.) |
| 10 | Supply and laying High-Density Polyethylene (HDPE) Double Wall Corrugated (DWC) non metalic pipe designed for underground cable management, Resistance to compression -type 450, resistance to impact -normal, resistance to bending - pliable, resistance to external influence- ingress protection IP67, resistance against corrosion - without protection, resistance to flame propagation-Non flame propagation, Nominal outside diameter 63mm, minimum inside diameter 47mm confirming to IS 16205 (Part-24) -2017 Including all necessary accessories such as couplers, bends, sockets, and jointing materials, complete all as specified and as directed. |
| 11 | Supply and laying High-Density Polyethylene (HDPE) Double Wall Corrugated (DWC) non metalic pipe designed for underground cable management, Resistance to compression -type 450, resistance to impact -normal, resistance to bending - pliable, resistance to external influence- ingress protection IP67, resistance against corrosion - without protection, resistance to flame propagation-Non flame propagation, Nominal outside diameter 75mm, minimum inside diameter 56mm confirming to IS 16205 (Part-24) -2017 Including all necessary accessories such as couplers, bends, sockets, and jointing materials, complete all as specified and as directed. |
| 12 | Supply and fixing energy efficient LED security light fitting of 70 Watt pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street luminaire, with driver, fixing the light fitting with existing bracket complete fitting with all accessories and following specifications, including taking down old light fitting of any make and condition complete all as specified and as directed. :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) |
| 13 | Material and labour for electric connection of street light with and including by using two core (2x1.5sqmm) high-conductivity multistranded annealed copper (Class 5 flexible) flat/round cable, PVC insulated and overall PVC sheathed, 1100 volt Conforming to IS 694 : 2010, from junction box to light fitting drawn through protection pipe, including taking down old connection wire of any size and condition complete all as specified and as directedNote :- Cable Protection pipe shall be measured and paid separately under appropriate item of BOQ. |
| 14 | Dismantling cable protection GI tubing light grade of any size from fixed along pole etc including fittings and clamps in any condition complete all as specified and as directed. |
| 15 | Supply and fixing GI tubing light grade of size 15 mm bore, ISI marked, fixed along poles/walls for cable protection including pipe fittings (elbow, tee, socket etc), pipe fixed with and including MS clamps of suitable size, nut bolts etc complete all as specified and as directed. |
| 16 | Supply and fixing in replacement bracket for street light made out of GI tubing light grade 25mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos suitable size clamp made out of MS Flat iron of size 25x4 mm with suitable nuts, bolts and washer for holding/fixing of bracket on steel pole including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete all as specified and as directed. |
| 17 | Dismantling the PCC around pole and pole foundation upto any depth and taking out old PCC pole of any size, making good for foundation of new pole with complete taking out dismantled PCC and including extra excavation/cutting if required, including removing all dismantled material obtained from foundation and PCC pole from site complete all as specified and as directed. |
| 18 | Supplying and erecting factory made Steel Tubular swaged pole with a swan neck bracket for mounting fixtures, made out of High-quality steel with an ultimate tensile strength of 42 kgf/mm² and Breaking load is rated at 517 kgf, with a crippling load of 367 kgf, complete with cast iron/mild steel base plate, finial taper plug, foundation bolts & nuts of size and number as recommended by manufacturer, as specified type 410-SP-31 (9 metre long) conforming to IS-2713 (Part-I & II) and features a triple-section design with diminishing diameters from base to top, including drilling of necessary holes, welded and reduced section and longitudinal weld seam throughout entire length of pole, duly painted with two coats of black bituminous paint throughout internally and externally upto planting depth and remaining external portion of pole with two coats of aluminium paint over a coat of red oxide primer, after erecting painting to pole upto 1.5 metre height from PCC coping with two coats of synthetic enamel paint in alternate (colour as decided by GE) strips 30 cm wide each strip (05 Nos) including marking pole number in letters & figures of size not less than 10cm height with red colour enamel paint, including Construction of suitable shallow foundation as recommended by OEM with M25 grade concrete for grouting the bolts and erecting the pole complete all as specified and as directed.Note:- (i) Cost of foundation, foundation nut bolts, and all other fixing material as required shall deemed to be included in the quoted unit rate. (ii) Srl number will be issued by Engineer-in-Charge. |
| 19 | Supply and fixing factory made street light timer box suitable size, IP66 protection class 2, outdoor type made out of CRCA sheet powder coated, having provision for front opening with hinges single door including locking arrangements (chromium plated 19 mm dia fancy lock), including provision of rubber beading and cable glands for each cable to make it weather and vermin proof, and shall be mounted on angle iron frame and 04 No legs made from angle of size 25 x25 x4mm with suitable length, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, pre-wired circuit should be multistrand single core FRLSH min size of 10 Sqmm copper cable, fitted with and including the following accessories and including taking down old with fitting of any make and condition complete all specified and as directed :-(i) MCCB 63 Amp, TPN, 25KA - 01 No (ii) Contactor rating 65Amp 3pole/230V(iii) Digital timer programmable switch for street light ON/OFF(iv) LED Indicated Lamps and selector switchNote :- Legs shall be grouted in PCC with suitable ground clearance, PCC work, Excavation and earth work and making good disturbed surfaces shall be measured and paid separately under appropriate item of BOQ. |
| 20 | Supply, installing, commissioning and testing factory made Sheet metal enclosure/ LT Bus bar chamber (out door for 415 volts, 3 phase, 4 wire AC supply) cubical type of size 300X300X200mm, minimum IP-54 class protection, made out of 3.15 mm thick CRCA epoxy powder coated sheet, factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns, having 4 Nos aluminium bus bar rated 100Amp and shall be insulated with colour code heat shrinkable sleeve and shall be mounted on suitable size \\"F\\" class insulator, having front opening with hinges single door including locking arrangements (chromium plated 19 mm dia fancy lock) including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, Chamber shall be mounted on angle iron frame and 04 No legs made from angle of size 25 x25 x4mm with suitable length, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed.Note :- Legs shall be grouted in PCC with suitable ground clearance, PCC work, Excavation and earth work and making good disturbed surfaces shall be measured and paid separately under appropriate item of BOQ. |
| 21 | Supply and fixing cable junction box of minimum Size 210mm x 155mm x 92mm or any other higher size complete with fixing accessories made from glass fiber-reinforced Sheet moulding compound (SMC) designed for outdoor use, with IP 66 rating in accordance with IEC 60529, having 3-phase aluminium bus bar system (440V, 50 Hz) supported on non-hygroscopic insulators to maintain electrical clearance and duly stepped or angled for easier cable connection (incoming and outcoming), including single pole 10KA MCB of 6 Amps rating mounted on DIN rail, including 2.5 Sqmm copper conductor multistrand single core FRLSH cable for connections between the bus bar and the MCB, junction box shall be mounted on pole with and including suitable size of mild steel clamps and nut bolts duly painted complete all as specified and as directed. |
| 22 | Net CONTRACT SUM will be worked out in General Summary after deduction of ‘CREDIT SCHEDULE’ amount inserted by MES. Please Enable Macros to View BoQ information |