| 1 | M&L in replacement of flexible fire retardant canvas connector cloth suitable for AHUs duct connection including removing of old one complete all as specified and directed by Engineer-in-charge. |
| 2 | S&F in replacement rubber insulating mat class A type, chequered, size 2 Mtr x 1 mtr x 25 mm thickness, for working voltage 3.3 KV complete all as specified and as directed. Make : Jyoti /Dunlop or Equivalent |
| 3 | S&F Acoustic treatment/ lining of area of AHU room with 22G, GI channels of 50x50 mm size fitted at 600x600mm girds. These girids will be fitted with 50mm thick 32 kg/cum fiber glass insulation covered be fiber glas tissue and 24 G Al perforated sheet and as required . The joint shall be minimium overlapping of 75mm with 30mmx 3mm aluminium strip covering. All corners shall be provided with 20x20x2mm aluminium angle with stainless steel counter sunk screws complete all as specified and directed. |
| 4 | M&L in replacement of duct insulation with 25mm thick Nitrile Rubber insulation of class \\"o\\" fire retardant with Mechanical protection over insulation with fiber glass cloth & UV paint (for exposed duct) for Ducts installed outside (exposed to sunlight) complete all as specified and directed by the Engineer-in-charge. Make:KAIFLEX/KFLEX/VIDOFLEX |
| 5 | M&L for insulation of MS pipe of size 40 mm dia heavy grade with all fittings laid in floors or fixed to walls and ceiling etc including PUF insulation and aluminium cladding including taking out/ down of existing pipe complete all as specified and directed by Engr-in-Charge. |
| 6 | All as per item No. 5.00 here-in-before but size of pipe 50mm dia. |
| 7 | All as per item No. 5.00 here-in-before but size of pipe 80mm dia. |
| 8 | All as per item No. 5.00 here-in-before but size of pipe 100mm dia. |
| 9 | All as per item No. 5.00 here-in-before but size of pipe 150mm dia. |
| 10 | All as per item No. 5.00 here-in-before but size of pipe 200/250mm dia. |
| 11 | M&L for Dismantling old/Unserviceable/rusted ,Supply/Return/Fresh Air GI Duct of any size/shape/dia with insulation from walls, roofs, ceiling for replacement complete Including Ducting Supports , rubber gaskets, elbows, vanes, & supports as per (IS 655) etc. from any location at Central AC plants Under GE(U) P&M Delhi Cantt compelte all as specified and directed by engineer-in-chrage. |
| 12 | (a) 24 gauge ( thickness 0.63mm ) |
| 13 | (b) 22 gauge ( thickness 0.80mm ) |
| 14 | Supply, fabrication ,Installation, Balancing and Commissioning of fabricated GSS sheet metal rectangular ducts/ elbows in repairs as per site requirement with supports as per IS 655-2010 complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as site requirements of following sheet thickness complete as required at site all as specified and directed by engineer-in-charge.Make:SAIL/TATA/JINDAL |
| 15 | 24 gauge ( thickness 0.63mm ) |
| 16 | 22 gauge ( thickness 0.8mm ) |
| 17 | Supply and installation in replacement of 50mm thick resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier insulation in existing ducts of AC plants, applying rubber based adhesive CPRX compound including wraping, pasting complete and cover the insulation one side with GI wire Mess netting after cleaning the duct surface (to be insulated ) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leakproof against any leakage and securing the insulation with and including mechanically fastened nylon/ steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mtr, including taking down old unserviceable one, complete all as directed by Engr-in-Charge. Make:- Shri Fire Pack/ Impex Insulation/ Trans Insulation. |
| 18 | M&L for dismantling of existing Air Handling Unit of any capacity, cleaning, servicing, overhauling to all component of AHU, with and including cleaning of heating & cooling coil with caustic soda solution, including welding/ brazing, wherever required to arrest leakages, cleaning of Pre-Micro Filters, replacing of vertical GI sheet supports, complete replacement of foam insulation of best quality using adhesive substance to avoid cold air leakages complete all as specified and as directed. |
| 19 | M&L for maintenance of AHU supply panel / feeder pillar/LT panel indoor/outdoor type including removing the carbonized/melted sparked thimbles, cleaning the carbonized bus bar making cable ends fresh and supply and crimping new thimbles/lugs and fixing the cable on bus bar/MCCB/Main switch/MCB including providing new nut bolts and washer if required greasing the doors of feeder pillar/LT panel outdoor/indoor type complete all as specified & directed by Engr-in-Charge. |
| 20 | M&L for cleaning inside surface of Air supply return/exhaust ducts all grills, dampers & diffusers of HVAC system by using high power vacuum air compressor, robotic camera air hammer, special nozzle, air sweep with other required accessories giving/showing inspection of dust before and after cleaning of duct upto the satisfaction of Engr-in-Charge. Note :- (A) The contractor is responsible for any damage/breakage caused at the time of cleaning and the contractor will repair/replace the same without any extra cost to the Govt.(B) The mesurement of cleaning of Duct shall be mesured as per the room area the duct is feeding. |
| 21 | Supply & Fixing Pre filter 10 micron of size 600mm x 600 x 50mm made of out of GI wire mesh interspaced with two crimp layers and three flat layers flanged deep box type and efficiency 90% as per existing size and pattern for the all three AC Plant air handling unit complete all as specified and as directed. MAKE:LLYOD/MIHIR/DANPOSS |
| 22 | ditto- all as per item No. 17 above but size 600mm x 300mm x 50mm. |
| 23 | ditto- all as per item No. 17 above but size 300mm x 300mm x 50mm. |
| 24 | M & L for V-belt for AHU blower motor and compressor motor of existing size, A-31, A-35, A-51, A-54, A-56, A-62, A-75, A-92, B-31,B-104, B-106, B-107 etc complete all as specified and as directed. |
| 25 | Supply and fixing in replacement of AHU Shaft bearing No. P-207/ P-208 or existing size as per site requirement complete all as specified and as directed. |
| 26 | Supply and fixing in repairs of bottom tray for fan and coil section made out of MS sheet 1.6mm thick duly painted with two coats of synthetic enamel paint (1st grade quality) through spray machine over a coat of red oxide chrome primer with 25mm thick thermocol insulation covered with tarfelt for AHU complete all as specified and as directed. |
| 27 | Supply and fixing in repairs cast iron butter fly valves lever operated SS disc type nitrile/EPDM rubber lining PN 16 of dia 100 mm complete all as specified and directed by the Engr-in-Charge. (Make: - AUDCO/ LEADER/ ZOLOTO). |
| 28 | ditto- all as per item No. 23 above but 80mm dia. |
| 29 | ditto- all as per item No. 23 above but 65mm dia. |
| 30 | ditto- all as per item No. 23 above but 50mm dia. |
| 31 | ditto- all as per item No. 23 above but 40mm dia. |
| 32 | M&L in replacement of automatic fire suppression system for electric panel 4 KG Fire Suppression System with UL approved FK-5112 Clean Agent ensures eco-friendly, residue-free protection. Seamless alloy steel cylinder, nickel-plated brass valve with gauge, and heat- sensitive detection tubing provide automatic discharge Fire Detection Tube Heat sensor Tube HR red \\"Fire Finder\\" Heat Sensor Tube for automatic fire suppression System-Heat Sensor tube for automatic fire suppression system made by special modified Polyamide (PA), Color Red, High grade HR quality, UV Stabilized, Inner diameter 4mm, Outer Diameter 6 MM, and include End of Line adapter with Pressure gauge for Automatic fire suppression tube used for fitting at the end of the tube for pressurizing and re pressurizing the tube. Fitting made by brass (plated / unplated), Stainless steel, Elastomeric Sealings and also Master Control Unit for connecting each system with electronic hooters and productivity input to Scada /Fire Alarm system including all necessaries + electrical wiring/sockets etc. to make each entire system functional also include Pressure Switch Pressure Switch to monitor Pressure drop in the tube, switch point 5 Bars all as specified and directed by Engineer in Charge. |
| 33 | M&L in replacement of automatic fire suppression system for electric panel 2 KG Fire Suppression System with UL approved FK-5112 Clean Agent ensures eco-friendly, residue-free protection. Seamless alloy steel cylinder, nickel-plated brass valve with gauge, and heat- sensitive detection tubing provide automatic discharge Fire Detection Tube Heat sensor Tube HR red \\"Fire Finder\\" Heat Sensor Tube for automatic fire suppression System-Heat Sensor tube for automatic fire suppression system made by special modified Polyamide (PA), Color Red, High grade HR quality, UV Stabilized, Inner diameter 4mm, Outer Diameter 6 MM, and include End of Line adapter with Pressure gauge for Automatic fire suppression tube used for fitting at the end of the tube for pressurizing and re pressurizing the tube. Fitting made by brass (plated / unplated), Stainless steel, Elastomeric Sealings and also Master Control Unit for connecting each system with electronic hooters and productivity input to Scada /Fire Alarm system including all necessaries + electrical wiring/sockets etc. to make each entire system functional also include Pressure Switch Pressure Switch to monitor Pressure drop in the tube, switch point 5 Bars all as specified and directed by Engineer in Charge. |
| 34 | M&L in replacement of automatic fire suppression system for electric panel 1 KG Fire Suppression System with UL approved FK-5112 Clean Agent ensures eco-friendly, residue-free protection. Seamless alloy steel cylinder, nickel-plated brass valve with gauge, and heat- sensitive detection tubing provide automatic discharge Fire Detection Tube Heat sensor Tube HR red \\"Fire Finder\\" Heat Sensor Tube for automatic fire suppression System-Heat Sensor tube for automatic fire suppression system made by special modified Polyamide (PA), Color Red, High grade HR quality, UV Stabilized, Inner diameter 4mm, Outer Diameter 6 MM, and include End of Line adapter with Pressure gauge for Automatic fire suppression tube used for fitting at the end of the tube for pressurizing and re pressurizing the tube. Fitting made by brass (plated / unplated), Stainless steel, Elastomeric Sealings and also Master Control Unit for connecting each system with electronic hooters and productivity input to Scada /Fire Alarm system including all necessaries + electrical wiring/sockets etc. to make each entire system functional also include Pressure Switch Pressure Switch to monitor Pressure drop in the tube, switch point 5 Bars all as specified and directed by Engineer in Charge. |
| 35 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, armoured, electric power cables (heavy duty) 1100 Volts grade with aluminium conductor of cross sectional area 25 Sqmm, 4 core with galvanized steel strip or wire including taking down old unserviceable one complete all as specified and as directed. Make:Havells/Polycab/KEI Industries |
| 36 | ditto- all as per item No. 31 above but cross sectional area 16 Sqmm, 4 core. |
| 37 | ditto- all as per item No. 31 above but cross sectional area 10 Sqmm, 4 core. |
| 38 | ditto- all as per item No. 31 above but cross sectional area 6 Sqmm, 4 core. |
| 39 | S&F in repair cable tray of size 150 x 50 mm and thickness 3.00 mm complete all as specified & directed. |
| 40 | ditto- same as item No 35 but of size 300 x 50 mm. |
| 41 | M&L for dismantling the old broken existing pvc tank and S&F in replacement 200 Litre capacity Rotational moulded polyethylene water storage tank, triple layered, food grain plastic (rectangular shape with closed top), hoisted and fixed in position on existing wall, stage, roof or RCC staging complete all as specified in SSR Part-I including supply and connecting tank nipple, float valve etc., making complete connection of inlet and out let pipe, fixing of GI pipe (over flow) & washout to the nearest rain water drain complete all as specified and as directed. Make:SINTEX/VECTUS/SUPREME |
| 42 | S&F in replacement humidity self priming motor pump set of cap 0.5 HP single phase 240 volt of AC plant, fitted with thermal overload protector & IP-44 protection, 'B' class of insulation, Both side ball bearing double shielded including necessary GI tubing connection for incoming / outgoing supply complete all as specified and as directed. Make:- ABB/CROMPTON/ KIRLOSKAR |
| 43 | M&L for frame work with angle iron for frame support, with fabrication, welding joining including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 including taking down old unserviceable one complete all as specified and as directed. |
| 44 | M&L for taking out old UNSV/rusted GI water tubing of 25 mm dia. |
| 45 | ditto- all as per item No. 40 above but 20 mm dia. |
| 46 | ditto- all as per item No. 40 above but 15 mm dia. |
| 47 | Supply laying, connecting and testing GI water tubing 25 mm bore, medium grade, with all fittings, with screwed and socketed joints, laid in trenches/floor or fixed to wall or surface and making good the disturbed surface complete all as specified and as directed. Make : Jindal/ Tata/OSWAL |
| 48 | ditto- all as per item No. 43 above but 20 mm dia. |
| 49 | ditto- all as per item No. 43 above but 15 mm dia. |
| 50 | Supply & Fixing shock absorbing rubber pads at the bottom of the AHU unit for absorbing shocks and vibrations, heavy duty of size 150 mmx 150mm complete all as specified and as directed. |
| 51 | M&L for dismantling the old broken existing PVC tank and S&F in replacement 2000 Litre capacity Rotational moulded polyethylene water storage tank, triple layered, food grain plastic (cylindrical, vertical with closed top), hoisted and fixed in position on existing wall, stage, roof or RCC staging complete all as specified in SSR Part-I including supply and connecting tank nipple, float valve etc., making complete connection of inlet and out let pipe, fixing of GI pipe (over flow) & washout to the nearest rain water drain complete all as specified and as directed. Make- SINTEX/ROTEX/SUPREME |
| 52 | S&F in repair/replacement Compound pressure gauge (Discharge pressure) of size 100 mm dia suitable for 0 to 150 PSI complete all as specified and as directed.MAKE:FIEBIG/H GURU/EMERALD |
| 53 | S&F in repair/replacement of existing AHU door including nut, bolt, door lock, door glass, door handle, door hinges etc complete all as per specified and directed |
| 54 | S&F in replacement DOL starters for motors of 5/7.5 HP capacity with suitable rating relay, suitable for mounting on existing LT Panels of AC plants and connections with suitable size single core copper conductor wire complete all as specified and directed by Engr-in-Charge. (Make -L&T/Siemens/Legrand/ ABB/Crompton.) |
| 55 | Taking down carefully existing surface/ concealed unserviceable aluminum/ copper point wiring (light, fan, socket, power or sunken box) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, etc. and making good to disturbed surfaces of walls, floors, ceilings, etc. where required and finished the existing surfaces after complete of new point wiring as specified here-in-after complete all as specified and as directed. |
| 56 | M&L for concealed point wiring with 1.5 sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including PVC conduit (medium grade) of adequet size dia with all fittings and accessories including 2mm thick sunk MS pressed steel terminal boxes of appropriate size with 3.0mm thick plastic laminated sheet top cover with cadmium plated iron screws complete including PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi stranded copper conductor cable of size 1.5 sqmm green colour as earth continuty conductor connected to common earth dolly for one light/ fan point controlled by one, one way switch complete all as specified and as directed.(Make of Cable:- FINOLEX/ HAVELLS/ POLYCAS) |
| 57 | All as per item No. 52 here in before but for One 5 Amp socket out let independent. |
| 58 | All as per item No. 52 here in before but for One 5 Amp socket out let on same board |
| 59 | All as per Srl item No 52 here-in-before but for one power point 6 pin 15 Amps socket out let with 2.5 Sq mm stranded copper conductor cable PVC insulated including earth wire 2.5 Sq mm copper conductor cable connected to earth dolly complete all as specified & directed by-in-Charge. |
| 60 | S&F in of switch Piano flush type SP, one way 5 Amps complete all as specified and directed. |
| 61 | S&F in of switch Piano flush type SP, one way 15 Amps complete all as specified and directed. |
| 62 | S&F in of socket outlet 2 in 1, 3 pin 5 Amps. complete all as specified and directed. |
| 63 | S&F socket outlet 2 in 1, 3 pin 5 and 15 Amps, flush type complete all as specified and directed. |
| 64 | S&F in replacement of polycarbonate ceiling rose 3 pin flush type 6 A 250 V AC with ISI mark including ring for jumbo ceiling rose complete all as specified and directed. |
| 65 | Supply and fixing stepped type electronic fan regulator flush type complete all as specifed and directed |
| 66 | Supply and fixing in replacement thermostat for AHU room, as per existing size & specification complete all as specified and as directed. (Make:-SIEMENS/ DANFOSS/ INDFOSS/ANERGY). |
| 67 | S&F in replacement of basic all purpose surface and wall mounted LED batten 20 Watt with polycarbonate housing & intigrated electronic driver with all necessary fixing accessories complete all as specified and as directed. (Make : Havells/phillips/bajaj) |
| 68 | S&F in replacement LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-in-Charge. Make : Havells/Phillips/Bajaj |
| 69 | S&F in replacement aluminium lugs for cable of cross sectional area 10 to 35 Sqmm complete all as specified and directed by Engineer-in-charge. |
| 70 | S&F in replacement aluminium lugs for cable of cross sectional area 70 to 185 Sqmm complete all as specified and directed by Engineer-in-charge. |
| 71 | S&F in replacement copper lugs for cable of cross sectional area 10 to 25 Sqmm complete all as specified and directed by Engineer-in-charge. Please Enable Macros to View BoQ information |