| 1 | Dismantling/taking out defective compressor unit from window type/split type AC and S&F same model new one company sealed compressor (rotary type) of 1.5 TR capacity complete with connecting fitting and fixtures making brazing work and leak test and including recharging refrigerant R -22/ R32/R410 including soldering of copper pipes, replacement of foundation rubber bushes, nuts, bolts etc complete all as specified and directed by Engr-in-charge Make :- KIRLOSKAR/COPELAND /CARRIER/TECUMESH /VOLTAS /TOTALINE/HITACHI |
| 2 | Dismantling/taking out defective compressor unit from window type/split type AC and S&F same model new one company sealed compressor (reciprocating type) of 1.5 capacity complete with connecting fitting and fixtures making brazing work and leak test and including recharging refrigerant R -22/ R32/R410 including soldering of copper pipes, replacement of foundation rubber bushes, nuts, bolts etc complete all as specified and directed by Engr-in-charge Make :- KIRLOSKAR/COPELAND /CARRIER/TECUMESH /VOLTAS /TOTALINE/HITACHI |
| 3 | Dismantling/taking out defective compressor unit from window type/split type AC and S&F same model new one company sealed compressor ( rotary type) of 2 TR capacity complete with connecting fitting and fixtures making brazing work and leak test and including recharging refrigerant R -22/ R32/R410 including soldering of copper pipes, replacement of foundation rubber bushes, nuts, bolts etc complete all as specified and directed by Engr-in-charge Make :- KIRLOSKAR/COPELAND /CARRIER/TECUMESH /VOLTAS /TOTALINE/HITACHI |
| 4 | M&L for servicing of window type/split type AC of 1.5/2.0 tone capacity by taking out the same from existing location, cleaning of condenser, cooling coil, and other components with cooling coil rinse solution and clean water, greasing of fan, motor, blower etc without damage any part and reinstall at the same location all as directed by the Engineer-in-Charge.Note-Spare parts shall be measured and paid sapertaly.(Note: The contractor shall at his own cost arrange water for servicing purpose.) |
| 5 | S&F in replacement of starting relay assembly including clips and terminal cover suitable for window type/split type 1.5 TR/2 TR capacity AC complete all as specified and directed by Engr-in-charge. |
| 6 | S&F in replacement of starting capacitor 80/100/120 MFD including thimble for connection suitable for window type/split type 1.5 TR/2 TR AC complete all as specified and directed by Engr-in-charge Make : HAVELLS / HPL / DUCATI / EPCOS/ NEPTUNE |
| 7 | S&F in replacement of running capacitor 45/50 MFD including thimble for connection suitable for window type/split type 1.5 TR/2 TR AC complete all as specified and directed by Engr-in-charge.Make : HAVELLS / HPL / DUCATI / EPCOS/ NEPTUNE |
| 8 | S&F in repairs blower DC fan motor suitable for 1.5/2.0 Ton split AC of capacity Single Phase for indoor unit complete all as specifed and directed. |
| 9 | S&F in repairs blower fan motor suitable for 1.5/2.0 Ton split AC of capacity Single Phase for indoor unit complete all as specifed and directed. |
| 10 | M&L for finding out the leakage with the pressure test of the condenser or cooling coil of window type/split type AC of 1.5/2.0 ton and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/soldering including charging the gas R-22 and testing the AC to the entire satisfaction of Engineer-in-Charge. |
| 11 | S&F in replacement condenser for window type AC 1.5 ton capacity of any make including charging of gas R-22 all as directed by Engineer-in-Charge. |
| 12 | S&F in replacement cooling coil for window type AC 1.5 ton capacity of any make including charging of gas R-22 all as directed by Engineer-in-Charge. |
| 13 | S&F in repairs condensing fan motor 1/5 HP single phase, 230 volts, 50 cycle per second suitable for Carrier window type AC complete all as specifed and directed. Make- as per existing site. |
| 14 | M&L for replacement of PCB control card suitable for 1.5/2.0 TR capacity split type AC, single phase complete all as specifed and directed. |
| 15 | Reparing of PCB control card suitable for 1.5/2.0 TR capacity split type AC, single phase complete all as specifed and directed. |
| 16 | M&L for fan blade of suitable size for 1.5/2 TR capacity of window/Split type AC complete all as specifed and directed. |
| 17 | S&F in repair copper tube of size ⅝” dia for any capacity of split type AC all as specified. |
| 18 | M&L for insulating foam pipe of size ⅝\\", ¼\\", and ⅜\\" dia of split type AC any capacity for both indoor and outdoor unit all as specified. |
| 19 | S&F single pole contactor suitable for split type AC capacity 1.5/2.0 Ton all as per specified and directed. Make as per existing site. |
| 20 | S&F in repair of flair nut size 5/8\\" and 1/2\\"dia for any capacity of split type AC all as specified. |
| 21 | S&F in repair of dead nut size 1/4 '' dia for any capacity of split type AC all as specified. |
| 22 | M&L for repairs of caplliary tube of split /window type AC capacity 1.5/2.0 Ton and all as per specified and directed. Make as per existing site. |
| 23 | 9.Material & labour for WATER JET servicing of CASSET TYPE AC's/DUCTABLE AC's of 2.5/4/5.5 Tonne capacity (complete indoor and outdoor unit by using service bag cover & cooling coil rinse solution for cleaning of coils), taking out the indoor top cover outdoor top cover from existing location, cleaning of cooling coil , condenser coil, and other components using clean water greasing of fan, motor, blower etc without damage any part and reinstall at the same location complete all as specified & directed by the Engineer-in-Charge.(Note: The contractor shall at his own cost arrange water for servicing purpose.) |
| 24 | Supply and filling refrigerant gas R-22 for charging in AC complete all as specified and directed by Engr-in-charge.Make :- FREON / MEFRON |
| 25 | Supply and filling refrigerant gas R-134A for charging water coolers/refrigerators complete all as specified and directed by Engr-in-charge. Make :- FREON / MEFRON |
| 26 | Supply and fixing in replacement of outdoor unit capacity 2 ton with fan motor ,fan blade and suction and discharge L key valve and capillary for cassette type 2 TR AC of existing make and model complete all as specified and directed by Engr-in-charge. |
| 27 | Opening up and disconnecting the defective unserviceable sealed compressor unit of water cooler storage type 60/120 ltr/hrs and supply and fixing new compressor existing make and model and including gas charging R22/R 134A and testing complete all as specified and directed by Engr-in-charge Make :TECUMSEH /KIRLOSKAR /WHIRLPOOL/COPELAND /VOLTAS |
| 28 | Opening up and disconnecting the defective unserviceable sealed compressor unit of water cooler storage type 150 ltr/hrs and supply and fixing new compressor existing make and model and including gas charging R22/R 134A and testing complete all as specified and directed by Engr-in-charge Make :-TECUMSEH /KIRLOSKAR /WHIRLPOOL/COPELAND /VOLTAS |
| 29 | M&L for servicing of water cooler any capacity by taking out the same from existing location, cleaning of condenser, cooling tank, and other components with cooling tank rinse solution and clean water, greasing of fan, motor, etc without damage any part and reinstall at the same location all as directed by the Engineer-in-Charge.Note -Spare parts shall be measured and paid separtely. |
| 30 | S&F in replacement of starting relay open type suitable for compressor of water cooler with clips, relay cover and screws complete all as specified and directed by Engr-in-charge. |
| 31 | S&F in replacement of thermostat switch including knob, plate, screws and necessary wiring of water cooler complete all as specified. |
| 32 | S&F in replacement of starting capacitor 40/60 /80/100MFD of water cooler complete all as specified and directed by Engr-in-charge. |
| 33 | S&F in replacement of running capacitor 36/45 MFD of water cooler complete all as specified and directed by Engr-in-charge |
| 34 | Taking down and dismantling condencing fan motor of water cooler and material and labour for rewinding with supper enamelled copper winding wire as per existing pattern including replacement of gun metal bushes, shaft, clamps including testing and commissioning complete all as specified and directed by Engr-in-charge. Make of wire : Devidayal / Chetak |
| 35 | M&L for repair to bottom rusted and deteriorated portion of body of 150/150 litres storage/cooling capacity of water cooler up to 300mm in height from bottom including replacement with 20 gauge mild steel sheet with necessary cutting, denting, welding including spray painting with one coat of approved synthetic enamel paint (Ist quality) over a coat of red oxide primer to the entire outer surface of the body after scraping, rubbing, and removing the existing old paint all as specified and directed. |
| 36 | S&F in replacement of fan blade of condensing motor for 120/150 ltr /hrs capacity water cooler etc complete all as specified and directed by Engr-in-charge. |
| 37 | S&F in replacement of 15 mm bore push type water tap brass chromium plated of water cooler complete all as specified and directed by Engr-in-charge. Make :- As per existing site |
| 38 | S&F in replacement of PVC flexible hose pipe, 32mm dia as in connections fixed at one end of waste water trap with clamp and other end left free to open at appropriate distance of water cooler complete all as specified and directed by Engr-in-charge. |
| 39 | S&F in replacement of condensing fan motor of capacity (1/5HP) including material and labour for replacement of mild steel clamps, rubber rings & capacitor of complete of water cooler all as specified and directed by Engr-in-charge. |
| 40 | S&F in replacement of condenser made out of copper tubes of heavy grade of adequate size of capacity 120/150 ltr /hrs of water cooler including necessary screws, brazing to existing gas pipes & testing complete all as specified and directed by Engr-in-charge. |
| 41 | M&L for finding out the leakage with the pressure test of the condenser or cooling coil of water cooler 150/150 litres storage/cooling capacity and dismantling the same for repair, reassembling the same after repair of the leakage point by brazing/soldering including charging the gas R-22/R-134 and testing the water cooler to the entire satisfaction of the Engineer-in- Charge. |
| 42 | M&L for finding out the leakage with the pressure test of the condenser or cooling coil of water cooler 60/120 litres storage/cooling capacity and dismantling the same for repair, reassembling the same after repair of the leakage point by brazing/soldering including charging the gas R-22/R-134 and testing the water cooler to the entire satisfaction of the Engineer-in- Charge. |
| 43 | Opening and disconnecting the defective unserviceable sealed compressor unit of refrigerator of any make and type AC 230 volts single phase of capacity 180-220 ltr and supply and fixing new compressor of existing make and model and including gas charging 134A complete all as specified and directed by Engr-in-charge. |
| 44 | Opening and disconnecting the defective unserviceable sealed compressor unit of refrigerator of any make and type AC 230 volts single phase of capacity 235- 320 ltr and supply and fixing new compressor obtained from the factory outlet/ authorised dealer under their replacement scheme including gas charging 134 A complete all as specified and directed by Engr-in-charge. |
| 45 | M&L for servicing of refrigerator any capacity by taking out the same from existing location, cleaning of condenser, freezer, and other components with freezer rinse solution and clean water, greasing of fan, motor, etc without damage any part and reinstall at the same location all as directed by the Engineer-in-Charge. |
| 46 | S&F in replacement of relay assembly suitable for 180-320 litre capacity refrigerator including relay cover, clips and screws complete all as specified and directed by Engr-in-charge.Make- As per existing site |
| 47 | S&F in replacement of thermostat switch suitable for refrigerator capacity 180-320 litre including knob, plate and screws complete all as specified and directed by Engr-in-charge.Make- As per existing site |
| 48 | S&F in replacement of condenser suitable for 180-320 ltr capacity refrigerator made out of mild steel powder coated tubes of heavy grade of adequate size including necessary mild steel clamps and mild steel CP screws, brazing and connecting to existing gas system complete all as specified and directed by Engr-in-charge. |
| 49 | S&F in replacement of Timer switch of refrigeartor of capcity 180-320 ltrs complete all as specified and directed. |
| 50 | S&F in replacement of evaporator / freezer cabinet complete with freezer door made out of aluminum tubes of adequate size for refrigerator of capacity 180-220 ltr including making connection with old system complete all as specified and directed by Engr-in-charge. |
| 51 | All as per srl item No 50 here-in-before but refrigerator of capacity 235-320 litre. |
| 52 | S&F in replacement of compact fan motor for indoor double door refrigerator 235 -320 ltrs complete all as specified and directed by Engr-in-charge. |
| 53 | S&F in replacement of fan motor condensing unit double door refrigerator 180 -320 ltrs complete all as specified and directed by Engr-in-charge. |
| 54 | M & L of repairing of PCB plate of invertor type refrigeartor of capcity 180-320 ltrs complete all as specified and directed. |
| 55 | Dismantling and taking out of burnt fan motor of desert coolers for upto 4000 CFM and material and labour for rewinding with supper enamelled copper winding wire of existing pattern, repair of shaft including replacement of insulation material, bushes, nuts, bolts, testing and commissioning etc complete all as specified and directed by Engr-in-charge.Make of wire : Devidayal / Chetak |
| 56 | S&F in replacement of fan motor of desert cooler suitable for upto 4000 CFM single phase, 230 volts, 3 speed with capacitor and bracket including connection to switch and testing complete all as specified and directed by Engr-in-charge. Make- KHAITAN/ POLAR /CROMPTON |
| 57 | S&F in replacement of submersible type water pump of desert cooler AC single phase 230 volt including necessary wiring connection and testing complete all as specified and directed by Engr-in-charge.Make- KHAITAN/ POLAR /CROMPTON |
| 58 | S&F in replacement of selector switch 3 speed 15 Amps for desert cooler complete all as specified and directed by Engr-in-charge.Make - HAVELL'S / CONA / CROMPTON |
| 59 | S&F in replacement of shutters of desert cooler of existing size made out of GI sheet handles duly spray painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge. |
| 60 | S&F in replacement of body parts of desert cooler bottom tank as per sample made out of 1.25 mm thick complete all as specified and directed by Engr-in-charge. |
| 61 | S&F in replacement of capacitor of capacity 4 MFD for motor of desert cooler complete all as specified and directed by Engr-in-charge.Make : HAVELLS / HPL / DUCATI / EPCOS/ NEPTUNE |
| 62 | S&F in replacement of switch piano flush type 5 Amp one way for water pump of desert cooler complete all as specified and directed by Engr-in-charge.Make :- LEADER / HAVELLS / LEGRAND |
| 63 | S&F in replacement of front grill of desert cooler as per sample made out of 1.25 mm thick GI sheet of size 520mmx550mm (approximate) complete with air control fins, mild steel CP screws, duly spray painted with synthetic enamel paint complete all as specified and directed by Engr-in-charge. |
| 64 | S&F in replacement of fan blade of fan motor of desert cooler as per sample made out of mild steel duly spray painted with synthetic enamel paint and fixed with mild steel CP screws complete all as specified and directed by Engr-in-charge. |
| 65 | S&F in replacement of PVC sheathed cable 3 core copper conductor of size 70/.0076mm, flexible for making connection of window type AC complete all as specified and directed by Engr-in-charge.Make :- Havells / RR Cable / NICCO / L & T / Finolex |
| 66 | S&F in replacement of plug top 3 pin 5 Amps heavy duty for refrigerator /desert cooler complete all as specified and directed by Engr-in-charge.Make :- LEADER / HAVELLS / LEGRAND /ANCHOR/BAJAJ |
| 67 | S&F in replacement of plug top 3 pin 15 amps heavy duty for water cooler, Voltage Stablizer & Air Conditioner complete all as specified and directed by Engr-in-charge.Make :- LEADER / HAVELLS / LEGRAND /ANCHOR/BAJAJ |
| 68 | M&L for scraping and removing of old paint of desert cooler body (steel surface) and preparation of steel surfaces including necessary denting/welding/cutting etc and spray painting two coats with smoke grey synthetic enamel paint (Ist quality) over a coat of red oxide primer on outer surface and inner surface i.e. water tank and body, fan mounting blades shall be painted with a coat of anticorrosive black paint over a coat of red oxide primer complete for desert cooler of any size and capacity complete all as specified and directed. |
| 69 | S&F wood wool pad set suitable for desert cooler for existing size complete all as specified and directed by Engr-in-charge. |
| 70 | BLANK |
| 71 | S&F in replacement of relay assembly suitable for 320 litre capacity deep freeze including relay cover, clips and screws complete all as specified and directed by Engr-in-charge.MAKE: INDFOS / VOLTAS. |
| 72 | S&F in replacement of condensor fan motor for Deep freezer 320 ltrs including installation, commissioning, testing etc complete to entire satisfaction of Engineer-in-Charge. |
| 73 | M&L for shifting of AC any type and capacity, from one location to another location including complete wiring, replacement of copper tubing with provn of complete insulation and leakage if any incl gas charging and testing after installation complete as directed. |
| 74 | S&F in replacement sub main wiring with 2 run of 6 Sq mm single core copper conductor cable drawn through in rigid PVC conduit ISI marked with fitting and 6.0 Sq mm single core copper conductor cable for continues earth wire all as directed. |
| 75 | S&F in replacement of desert cooler body of size approx 660 x 660 x 900 mm with and including front grill and three side louver fabricated out of 22 gauge mild steel plain GI sheet and bottom water tank (sump) of size 660x660x200mm deep fabricated out of 20 gauge mild steel plain GI sheet including taking out and reinstallation complete with standard fittings such as PVC pipe for water, electric controls and switch, fan speed regulator, rewiring of fan motor and water lifting pump including fixing and connecting existing cooler fan, electric pump with new 3 core PVC insulated & PVC sheathed cables (min. 3 metre in length). External surfaces shall be spray painted with two coats of approvedsynthetic enamel paint over a coat of red oxide primer and internal surface of body, cooler pump and motor shall be painted with two coats of bituminous paint over a coat of red oxide primer complete all as specified and directed by the Engineer-in-Charge. |
| 76 | Supply & Fix in replacement sheet metal enclosure with a two pin and earth plug socket complete including with 32 Amps MCB Single pole 240 Volt AC complete all as specified and a directed. |
| 77 | M&L in replacement for MCB single pole 6-32 Amps, 240 V . |
| 78 | M&L in replacement for MCB single pole & neutral 32 to 63 Amps, 240 V . |
| 79 | M&L in replacement for MCB triple pole & neutral 63 Amps, 240 V |
| 80 | Supply & fixing in replacement Complete Indoor unit with remote of Split AC capacity 1.5 Tonne any make complete all as specified & directed by the Engineer-in-Charge. |
| 81 | Supply and fixing in replacement of outdoor unit capacity 1.5 ton with fan motor ,fan blade and suction and discharge L key valve and capillary for split type 1.5 TR AC of existing make and model complete all as specified and directed by Engr-in-charge. |
| 82 | Supply and fixing in replacement of indoor unit capacity 2 ton with fan motor ,fan blade and suction and discharge L key valve and capillary for split type 2 TR AC of existing make and model complete all as specified and directed by Engr-in-charge. |
| 83 | S&F in replacement fan motor 3 phase 1.1 KW 380 V suitable for industrial cooler. |
| 84 | S&F in replacement fan motor 3 phase 1.4 KW ,22 HP, 440 V suitable for industrial cooler. |
| 85 | S&F in repair /rewinding fan motor 3 phase 1.1 KW 380 V suitable for industrial cooler. |
| 86 | S&F in replacement water lifting pump vertical type suitable for industrial cooler. |
| 87 | S&F in replacement wiring kit suitable for industrial cooler . |
| 88 | S&F in replacement fan blade of size 600mm with complete assembly suitable for industrial cooler including installation, commissioning, testing etc complete to entire satisfaction of Engineer-in-Charge. |
| 89 | S&F in replacement of TPN capacity 3 Amp for industrial cooler make as per existing all as directed by Engineer-in-charge. |
| 90 | S&F in replacement of honey pad suitable for kavva industrial cooler as directed by Engineer-in-Charge. |
| 91 | Labour only for attending complaints of domestic area of AF station Jodhpur (Outer and Inner domestic area) carrying out necessary repairs at site by replacing unserviceable spares or taking down carefully unserviceable Spare parts by disconnecting electrical connections, unsecrewing from position, to workshop for carry out necessary repairs or deposit unrepairable parts to E/M Store yard for safe coustody all as directed and specified. Please Enable Macros to View BoQ information |