| 1 | Dismantling of Plain or corrugated/galvalume steel sheeting/mild steel sheet in valley gutter, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed. |
| 2 | Supply and fix for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws |
| 3 | Supply and fix for pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in ridge, roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 4 | Supply and fix for 0.63 mm plain galvanised, mild steel sheeting, in ridges, hips, valley Gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275. fixed with self tapping /coach screws complete all as specified and as directed. |
| 5 | Supply and fix for 0.63 mm galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275. fixed with self tapping /coach screws complete all as specified and as directed. |
| 6 | Dismantling mild steel work of any description and in any position complete all as specified and as directed. |
| 7 | Supply and fix steel work in tubular trushes including special shaped washer etc complete using ERW or induction but welded tubes confirming to I.S. 1161-1979 grade St. 240 etc as in purlins complete all as specified and as directed. |
| 8 | Supply and fix rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming to Fe-410 W(Gde E-250) quality B complete all as specified and as directed. |
| 9 | Material and labour preperation of new steel surfaces of any desciption over 10 cm in width or girth not other wise descibed and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and as directed. |
| 10 | Dismantling of wall and ceiling boards (fibre,pulp insulation, Ac etc), any thickness including cover fillets complete all as specified and as directed. |
| 11 | Material and labour for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and as directed. |
| 12 | Material and labour for 8-9 mm thick gypsum board/tiles for insulation and accoustic purposes, 60cmx60cm in size , fixed with nails to timber frame work or with staples on snap grid in ceiling complete all as specified and as directed. |
| 13 | Demolition of reinforcement cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 14 | Supply and fix for providing precast cement concrete louvres and jallies, 35 mm thick (measured solid), including all mouldings using cement concrete type B0 1:2:4 (12.50 mm graded aggregate) set in cement mortar 1:4 complete all as specified and as directed. |
| 15 | Preparing new plastered surfaces on walls /jallies applying three coat of white wash(lime wash) complete all as specified and as directed. |
| 16 | Demolition of cement concrete unreinforced in ground floors and pavings n.exc. 15cm thickness below or above ground level complete all as specified and as directed. |
| 17 | Demolition of stone slabs/flooring of any description laid bedded and pointed any mortar complete all as specified and as directed. |
| 18 | Material and labour granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing types including 20mm thick screed bed in cement mortar (1:6) complete all as specified and as directed. |
| 19 | Material and labour for kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match including 15 mm thick screed bed in cement mortar (1:6) complete all as specified and as directed. |
| 20 | Description all as per ser No 19 but on step riser skirting over and including 10mm thick rendering in CM (1:4) complete all as specified and as directed. |
| 21 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations complete all as specified and as directed. |
| 22 | Supply and fix in repair mild steel, Fe 410-W (Gde E- 250 quality-A) Framed work as in doors or gates,roof structure of any size and section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; including all necessary fitting, also fastening and fixing,including dismantling, complete all as specified and as directed. |
| 23 | Material and labour cement concrete (1:3:6) type C-2 using 20 mm graded stone aggregate as in floor, plinth protection, 75 mm thick, surfaces finished even and fair without using extra cement as in plinth protection including provision of construction joints complete all as specified and as directed. |
| 24 | Demolition of precast concrete block /brick work walling built in cement mortar |
| 25 | Taking down cement plaster on wall /concrete surface etc including racking out joints hacking for key scrubing down with water etc all as specified and as directed. |
| 26 | Material and labour for precast cement concrete block masonry using type C1 1:3:6 (20 mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in mortar1:6 complete all as specified and as directed. |
| 27 | Material and labour for rendering 15 mm thick on faces of brick/ PCC block masonry wall using cement plaster 1:4 and rendering is to be finished even and smooth (without using extra cement) complete all as specified and as directed. |
| 28 | Material and labour preparation of newly plastered surface and applying two coat of cement base paint on wall etc complete all as specified and directed over alkali resistant primer complete all as specified and as directed. |
| 29 | Material and labour for rendering 15mm thick on fair faces brick work /PCC block masonary or concrete surface of wall using cement plaster 1:6 and finished even and smooth (without using extra cement) complete all as specified and as directed. |
| 30 | Material and labour preparation of newly plastered surface and applying two coat of oil bound Distember over a coat of primer on wall etc complete all as specified and as directed |
| 31 | Repairing the leaking deteriorated and torn out chajjas and parapet walls by removing all the lose material from the top of the chajja be means of light hammering and chiselling to remove loose concrete cover only and Clean all loose particles by high pressure jet water so that all surfaces should be sound, clean and free of contamination followed by application two coats of polymerised cementitious coat like Pidilite's Pidifin 2k or equivalent, while second coat is wet apply a 10mm dash coat of CM plaster with the water proofing compound Make : Dr.fixit or equivalent as approved by GE, completing the repair work by final finishing and providing with proper slope of 15 mm thick rendering cement mortar(1:4) including supply and mixing of waterproofing compound as per manufacturers instructions finishing the surfaces even and fair complete all as specified and as directed. |
| 32 | Cleaning the surface with wire brush, detecting sources of leakages and removing/taking down unsound treatment/surface and Material and labour for making holes with drill machine of dia 14mm for carrying out non-destructive waterproofing treatment to sunken portion of slab, floor and walls of bath, WC, WHB and floor traps (combined unit) by using construction chemical method as hydrophobic PU grouting, etc, with first course of injection MDI based PU foam and second course of injection PU plain all as per manufacturers instruction, etc, complete and as directed. The PU foam shall have 100% solids and solvent free, and shall expand 30-40 times its volume at liquid stage in presence of water, the PU plain injection shall have minimum 100 CPS viscosity and shore hardness minimum 50. (Make: PIDILITE or techno commercially equivalent) complete all as specified and directed. and Material and labour for fixing the metallic packer for hydrophobic PU foam and Sealer as per manufacturers specification |
| 33 | Material and labour for the tile joint chemical cleaning and re-grouting carefully by washing the existing tile with heavy duty tile cleaner preferably of M/S Pidilite or equivalent cleaner, again washing with fresh jet water, scratching the joints and filling the same with (white/matching colour) epoxy tile grout of M/s Pidilite, ROFF RTM epoxy or equivalent, curing, cleaning the surface etc, complete all as directed by Engr-in-Charge and as per the sample done at ground level. |
| 34 | Dismantling floor hearth or wall tilling including cement mortar bedding (but not backing ) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 35 | Material and labour for dholpur stone (16 to 18mm) thick cladding gang saw cut with machine cut edges, uniform colourof each stone sizenexceeding 0.5 sqmnarea fixed with and including one number SS clamps (grade -202) of flat-30mm X 2mm, 150mm longmade to shape in eachbslab, making V grooveat top and bottom of stone and drilling hole for hold fastener, polishing, rubbing &including siliconn treatment incl fixing firmly to to the wall. complete all as specified and as directed and as per the sample done at ground level. |
| 36 | Dismantling of cement concrete kerb stone from road edges and throw it of outside the MOD Land. |
| 37 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. Please Enable Macros to View BoQ information |