| 1 | Item no 1 : Rectification of leakages on risingmain distribution system pipeline includingnecessary excavation dewatering the trenchesmanually /machinery caulking the joints/cuttingthe pipe, fixing the new pipe in cutting portion,rectification for leakages with the help of CIDJoints/ jiffy collar coupling refilling the trenchesduring leakages. Material provided by the deptt. atfree of cost. As per rate analysisA) In soft soil1. For 63 mm dia. AC / PVC / CI /HDPE pipeline |
| 2 | For 75 mm dia. AC / PVC / CI /HDPE pipeline |
| 3 | For 80 mm dia. AC / PVC / CI /HDPE pipeline |
| 4 | For 100 mm dia. AC / PVC / CI /HDPE pipeline |
| 5 | For 125 mm dia. AC / PVC / CI /HDPE pipeline |
| 6 | For 150 mm dia. AC / PVC / CI /HDPE pipeline |
| 7 | For 180 mm dia. AC / PVC / CI /HDPE pipeline |
| 8 | For 200 mm dia. AC / PVC / CI /HDPE pipeline |
| 9 | For 250 mm dia. AC / PVC / CI /HDPE pipeline |
| 10 | For 300 mm dia. AC / PVC / CI /HDPE pipeline |
| 11 | For 350 mm dia. AC / PVC / CI /HDPE pipeline |
| 12 | For 400 mm dia. AC / PVC / CI /HDPE pipeline |
| 13 | For 450 mm dia. AC / PVC / CI /HDPE pipeline |
| 14 | For 500 mm dia. AC / PVC / CI /HDPE pipeline |
| 15 | B) In Concrete Road For 63 mm dia. AC / PVC / CI /HDPE pipeline |
| 16 | For 75 mm dia. AC / PVC / CI /HDPE pipeline |
| 17 | For 80 mm dia. AC / PVC / CI /HDPE pipeline |
| 18 | For 100 mm dia. AC / PVC / CI /HDPE pipeline |
| 19 | For 125 mm dia. AC / PVC / CI /HDPE pipeline |
| 20 | For 140 mm dia. AC / PVC / CI /HDPE pipeline |
| 21 | For 150 mm dia. AC / PVC / CI /HDPE pipeline |
| 22 | For 180 mm dia. AC / PVC / CI /HDPE pipeline |
| 23 | For 200 mm dia. AC / PVC / CI /HDPE pipeline |
| 24 | For 250 mm dia. AC / PVC / CI /HDPE pipeline |
| 25 | For 300 mm dia. AC / PVC / CI /HDPE pipeline |
| 26 | For 350 mm dia. AC / PVC / CI /HDPE pipeline |
| 27 | For 400 mm dia. AC / PVC / CI /HDPE pipeline |
| 28 | For 450 mm dia. AC / PVC / CI /HDPE pipeline |
| 29 | For 500 mm dia. AC / PVC / CI /HDPE pipeline |
| 30 | Item no 2 : Repairs to Dirty Water Supply andchockup of pipeline in distribution system after itsdetection necessary excavation cutting&champhering the pipe cleaning the chock protionby removing the pipe out of trenches cleaning byroding & relaying etc complete as directed byEngineer in charge etc complete. All materialrequired provided by department at free of cost.As per Rate analysis1. For 63 mm dia. AC / PVC / CI /HDPE pipeline |
| 31 | For 75 mm dia. AC / PVC / CI /HDPE pipeline |
| 32 | For 80 mm dia. AC / PVC / CI pipeline |
| 33 | For 100 mm dia. AC / PVC / CI pipeline |
| 34 | For 125 mm dia. AC / PVC / CI pipeline |
| 35 | For 150 mm dia. AC / PVC / CI pipeline |
| 36 | For 200 mm dia. AC / PVC / CI pipeline |
| 37 | For 250 mm dia. AC / PVC / CI pipeline |
| 38 | Item no 3: Disconnection of 15 mm/ 20mm/25mm& 40 mm dia G.I consumerconnections having outstanding dues againstwater charges or service connection line leakageincluding necessary excavation removing existingferrule fixed on distribution main on G.I. pipeconnection in register etc. complete as directedby Engineer in chargeAs per Rate analysis(A) For concrete Road connection |
| 39 | (B) For asphalt Road connection |
| 40 | Item No. 4 Providing Services for MakingDisconnection of 15 mm/ 20 mm/25mm& 40 mmdia G.I consumer connections as per the requestof the consumers, including removing existingferrule fixed on distribution main,closing holeson pipeline excluding necessary excavation andrequired materials etc. Complete as directed byEngineer in charge( Hon.MS/MJP Letter No 71 Dt-12/3/2024) |
| 41 | Item No.5 Providing and Making Reconnectionof 15 mm/ 20 mm/25mm& 40 mm dia G.Iconsumer connections as per the request of theconsumers including reconnecting existing ferrulefixed on distribution main Excluding necessaryexcavation and refilling and materials etc.Complete as directed by Engineer in charge( Hon.MS/MJP Letter No 71 Dt-12/3/2024) |
| 42 | Item No.6 Providing and making Shifting of 15mm/ 20 mm/25mm& 40 mm dia G.I consumerconnections as per the request of the consumers,dismanling/ reconnecting existing ferrule fixed ondistribution main Excluding necessary excavationand refilling and required materials etc. Completeas directed by Engineer in charge( Hon.MS/MJP Letter No 71 Dt-12/3/2024) |
| 43 | Item No 7 : Rent for Concrete breaker &Compresso rMJP CSR 2023-24 P.N.15 I.N.10 |
| 44 | Item NO 8: Supply of filter media fine qualitysand from any source having effective size 0.45 to0.70 and uniformity coefficient within the limit of1.3 to 1.7 within premises as per IS 8419 Part-1 of1977 including transportation loading,unloadingstacking and for all leads, (Rate As per MIDC CSRMECH/1) |
| 45 | Item No 9 :-Supply of filter media gravels at thedepartmental store of various sizes from 2 to50mm. Including all Leads, includingtransportation loading and unloading, stackingetc complete. (Rate. As per MIDC CSR MECH/2) |
| 46 | Item No 10 -Removing of filter media sand andgravel; including lifting stacking the same within50m. Lead from filter house.(Rate As per MIDCCSR MECH /3) |
| 47 | Item No 11 Filling the new gravels and fine sandin the filter beds properly in grades and layers asrequired including all labour and tools andplantsetc. Complete. Rate As per MIDC CSRMECH/S) |
| 48 | Item No 12: Conveying and laying of filter mediasand from godown to filterbox for lead up to 100m.( Rate As per MIDC CSR MECH/6) |
| 49 | Item No 13: Side Supervisor Please Enable Macros to View BoQ information |