| 1 | M&L for point wiring with FRLSH cable 1.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in and incl not less than 2mm thick PVC casing/caping with all accessories and 1.50 sqmm green in colour PVC copper conductor cable for earth continuity connected to common earth dolly incl PVC box surface/ flush type with PVC sheet for mounting fittings such as switches, sockets, fan regulators, etc One fan point controlled by one way switch and one regulator. |
| 2 | S & F switch piano, flush type single pole, one way 6 Amp all as specified and directed |
| 3 | M &L for Making new hole of suitable size into the wall with the heip of boring machine for mounting of metal exhaust fan 300 mm size,incl provisions for mounting the fan on walls and making good surface complete all as specified and directed. |
| 4 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers including provision of 3 core PVC insulated sheathed 1100 volts grade flexible cable with stranded copper conductor from ceiling rose to fan, length as per requirement at site also arrangement to mount the fan as per requirement complete all as directed. |
| 5 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm fixed in aluminium ventilations with necessary screws complete all as specified and directed |
| 6 | M& L For 18 to 20 mm thick ,Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite etc complete all as specified and as directed.. |
| 7 | Rounding to edges of stone slabs , such as in steps, cooking plateform, and other similar situation complete all as specified and directed. |
| 8 | Taking down chowkats or frames with shutter(without taking off shutters from the frames) n. Exc 1.50 sqm each and removing from site complete all as specified and directed. |
| 9 | Aluminium powder coated ventilators partly fix and partly lowered of aluminium section designed DG-2762 (40 mm x 32 mm x1.5 mm thick) (wt 0.668 kg/mtr) frame and DG-2763 and middle section of designed DG-2763 (40 mm x 32 mm x 1.5 mm thick) (wt 0.654 kg/mtr), middle section DG-2546 (17.27 mm x 17.15 mm x 1.22 mm thick) (wt 0.124 kg/mtr) including 5 mm thick pinheaded figured glass louvers with blades of 100 mm heavy duty including with aluminium lever handle fixed panel shall be provided with 4 mm thick pin headed figured glass including all necessary rubber packing, anodized aluminium snap beading fixed with minimum 6 Nos of suitable size galvanised screws with PVC plug etc including taking down old ventilator etc. complete all as specified and directed. |
| 10 | Dismantling wrought iron or mild steel work of any description not therwise provided for |
| 11 | M&L for framed work such as grills or grating etc with ends of bars shouldered as framed guard bars conforming to Fe-410-0 or 310-0 all as specified and directed. |
| 12 | S&F veneered decorative plywood 12mm thick, grade1 (with BWR resin) with decorative face veneers on one face, fixed with fixed with screws to timber frame work, complete all as specified and directed |
| 13 | S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and width of aperture 1.18mm & fixed with tinned tacks or galvanised wire staples with AL frame work complete all as specified and as directed. |
| 14 | Taking down cement plaster on brick or stone walls or concrete surface etc including raking out joints, hacking for key scrubbing down with water all as specified and directed. |
| 15 | M&L preparing newly plastered surfaces of wall and applying two coats of oil bound distemper over one coat alkali resistant primer on walls complete all as specified and directed. |
| 16 | M&L 15mm thick plastering on fair faces of brick or concrete surface in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed. |
| 17 | Supply , laying connecting and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured , electric power cables ( heavy duty) with stranded aluminium conductor 1100 volts grade in trenches/ passing through pipe/fixing on walls, floors etc incl using suitable clamp of cross sectional area 4 core 16 Sqmm Sqmm all as specified and directed. |
| 18 | Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable incl couplers & bends complete all as specified. |
| 19 | Excavation in trenches n exc 1.5m wide and n exc 1.5m deep and making good surface for laying /removing of cable all as specified and directed by Engr in charge |
| 20 | (a) Soft/loose soil |
| 21 | (b) Hard/dense soil |
| 22 | Returning filling in excavated soil in trenches, watering and well ramming in layers n exc 25 cm complete all as specified. |
| 23 | Removal of surplus excavated spoil to distance n exc 50 metre all as specified and directed. |
| 24 | M & L for GI tubing light grade with including all fittings for protection of cable laid in tranches or fixing to pole ducts/road crossing/on wall with suitable size of FI clamp complete of 40 mm bore all as specified and directed. |
| 25 | M & L for earthing complete with GI earth plate electrode of size 60 x 60 x 0.6 cms thick burried directly in ground vertically at a depth of not less than 2.25 Mtrs below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanised iron wire 4mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, 40 mm dia GI tubing light grade protection pipe upto test point, 20 mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30x30 CM made of RCC 1:3:6 with suitable handle, angle iron frame of angle iron size 40 x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, removal of surplus soil and returning filling in all as required at site all as specified in plate No 3 of SSR Part-I and directed by Engr-in-Charge. |
| 26 | S&F High galvanized mast light 15 Mtr high suitable for 6 to 9 lantern symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 6 mm dia 97/19 guage and double drum winch i.e motorised and manual with luminaire mounting arm, pully assembly, aviation obstruction light, lightning arrester spike including RCC foundation as per height and electric control panel complete all as specified and directed. |
| 27 | Supply and fix LED flood light fitting 200/210 watt with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP66 Protection with high luminous efficacy of 120 lm/w complete all as specified and directed (06 Nos on each high mast) Please Enable Macros to View BoQ information |