| 1 | Conversion of HT Network form LT Network at Central Jail, Varanasi |
| 2 | X-arm clamp for ST Pole |
| 3 | M.S. holding clamp for cable |
| 4 | Allu. Lugs for 630 sq mm |
| 5 | G.I. Pipe 6\\" dia |
| 6 | Cost of copper Z clamp for 400 KVA T/F with nut bolt & washer |
| 7 | H.S.Jointing kit for 11 KV 3x185 sq mm XLPE cable O/D |
| 8 | Loading unloading & carriage of 400 KVA T/F from Raja Talab central store to site |
| 9 | Loading unloading & carriage of ST Pole from central store to dump store and dump store to site |
| 10 | Loading unloading and carriage of Channel, Angle, Earthing rod, 33kv vcb,CT, PT & Decented. material etc. |
| 11 | Laying & Dressing of 11 KV 3x185 sq mm XLPE cable Double Circuit in Trench by digging of trench and cover with stock,brick,sand,patiya etc or in HDPE pipe with providing of HDPE pipe as required at site as per situation |
| 12 | Erection & Commissioning of PPMC & CT/PT Unit |
| 13 | Erection of D.P including grouting and plinthing of pole fitting fixing of S/S Base of M.S. Angle/Channel, fixing of all accessories |
| 14 | Errection & mounting of 400 KVA DP on Plinth and making connection and jumpring. |
| 15 | Sp. Earthing of 400 KVA T/F Netural & Body sepertaly with 2x60 fit G.I. pipe and connection with G.I. Strip off size 30x5 mm including cost of material |
| 16 | Sp. Earthing of PPMC with Chemical pipe and connection with G.I. Strip off size 30x5 mm including cost of material |
| 17 | Earthing of Pole by earthing rod |
| 18 | Erection, grouting & Nozelling of stay with grouting material AS PER NORMS |
| 19 | Jointing of HS O/D cable jointing kit for 11 KV 3x185 sq mm XLPE cable |
| 20 | Hoisting of 11 KV XLPE Cable through G.i. pipe with Proper Clamping |
| 21 | Painting of STP with fitting including cost of red-oxide primer and Al. Paints etc. |
| 22 | Civil work for Construction of meter room |
| 23 | Other Misc. work |
| 24 | Installation of LT Protection unit with LT Distribution Box and Air circuit Breaker on existing 250/400 KVA DTR for Central Jail Varanasi |
| 25 | Supply of Outdoor type LT ACB Boards pannel openable in front and back suitable for 3 plase, 4 wire, 50Hz AC supply . The Cubicle should be weather proof, dust proof and enclosure protection shall be IP-55 as per IS 2147-1962 and IS: 8623. The panels/switches boards shall be fabricated out of 14-SWG CRCA sheet steel including suitable foundation as per specification given below- a. 1 Set of 800 Amp. FP ACB Fix type with Spreader & Extended handle b. Metering on Incomer - 1 Set of Digital energy meter along with ring type CT for incommer Bus Bar c. 1 Set of LED type Phase Indicating Light (22.5 mm.) (SUITABLE FOR 250/400 KVA DISTRIBUTION TRANSFORMER) |
| 26 | Supply of Indoor type LT Disribution Boards pannel, openable in front and back suitable for 3 plase, 4 wire, 50Hz AC supply . The Cubicle should be weather proof, dust proof and enclosure protection shall be IP-55 as per IS 2147-1962 and IS: 8623. The panels/switches boards shall be fabricated out of 14-SWG CRCA sheet steel including suitable foundation as per specification given below- a. 1 Set of 400 Amp. TP MCCB with Spreader & Extended handle for Servo Bypass.b. Incommer 1 set of 500 amp. main MCCB with Spreader & Extended handle for Distribution pannelc. 1 Set of 200 Amp. TP MCCB with Spreader & Extended handle for DG set.d. 1 Set of 200 Amp. TP manual Changeover switch with Spreader & Extended handle for DGe. Outgoing 3 set of 200 amp, 2 set 125 amp and 2 set of 63 amp MCCB switch with Spreader & Extended handle for Out going LT circuit at diffrent areasf. Metering on Incomer - 1 Set of Digital energy meter along with ring type CT for incommer Bus Bar g. 1 Set of LED type Phase Indicating Light (22.5 mm.) h. Alluminium Busbar suitable for 800 amp. |
| 27 | Supply of Outdoor type LT Disribution Boards pannel openable in front and back suitable for 3 plase, 4 wire, 50Hz AC supply . The Cubicle should be weather proof, dust proof and enclosure protection shall be IP-55 as per IS 2147-1962 and IS: 8623. The panels/switches boards shall be fabricated out of 14-SWG CRCA sheet steel including suitable foundation as per specification given below for workshop etc- a. Incommer 1 Set of 250 Amp. TP MCCB with Spreader & Extended handle b. Outgoing 3 Set of 100 Amp. TP MCB with Spreader & Extended handle c. Outgoing3 Set of 63 Amp. TP MCB with Spreader & Extended handle d. Outgoing3 Set of 40 Amp. TP MCB with Spreader & Extended handle e. Outgoing3 Set of 25 Amp. TP MCB with Spreader & Extended handle f. 1 Set of LED type Phase Indicating Light (22.5 mm.) |
| 28 | LT XLPE Cable Al 1X630sqmm |
| 29 | Al lug for 630 sq.mm cable |
| 30 | Copper Z clamp as required for 630/400KVA T/F |
| 31 | Loading unloading & safe carriage of LT DB Box |
| 32 | Erection commissoing & testing of LT ACB Box on Existing outdoor Plinth for 250/400 Amp Transformer along with providing and fixing all required material then making connection with DTR and LT Distribution pannel. |
| 33 | Erection commissoing & testing of LT Distribution Box on Existing Control room for incomming and outgoing circuit along with providing and fixing all required material then making connection with all outgoing circuit. |
| 34 | Laying and dressing od LT cable by clamping properly |
| 35 | Earthing of All types of LT Pannel at two pint by providing and fixing of Chemical pipe eath rod of 38mmdia and connecting with 30x5mm GI earth strip cpmplete in all respect |
| 36 | Replacement of Old and Damage conductor of L.T. Line by ABC at Central jail varanasi |
| 37 | Dead end clamp with eye hook |
| 38 | Suspension clamp with eye hook |
| 39 | Cross arm clamp for Eye hook |
| 40 | LT Cable S/C 1x35 sq mm |
| 41 | LT Distribution Box |
| 42 | LT Insulated piercing clamp for enagiging D/B |
| 43 | LT bare netural connector ( P.G. Clamp) |
| 44 | M.S. Nut & Bolts off size |
| 45 | Stay clamp with N&B |
| 46 | Cartage of following material from Raja ka Talab Store to site including loading & unloading |
| 47 | A) ABC Size (3x120+1x95+1x16) & (3x50+1x35+1x16) sqmm and Other material as per estimate |
| 48 | B) S T Pole 9 meter long |
| 49 | Dismantling of Old and damage LT Conductor including rolling back its conductor , clamps, insulators etc. including loading ,cartage and unloading of these materials from site to JE dump store. |
| 50 | Erection & commissioning of (3x120) and 3x50 sq mm XLPE ABC with All accessories Dead end clamps, Suspension clamps, LT Cable S/C, Connector such as Clamp for pole and Eye Hook etc |
| 51 | Grouting of stay it nozelling fixing of stay wire complete including cost of grauting Material |
| 52 | Disconnection of LT service line of consumers before dismentling of old LT line and the reconnection through distribution boxes after commissioning of ABC line. |
| 53 | Fixing of Dist. Boxes on LT Pole including all clamps and material for mounting, connection & sealing |
| 54 | Errection, grouting & plinthing of STP 9 Mtr including cost of grouting material |
| 55 | Earthing of pole by earth rod |
| 56 | Painting of STP 11 mtr & fitting with one coat of Red-Oxide Post Man colour & two coat Al. Paints including cost of materials Please Enable Macros to View BoQ information |