| 1 | Dismantling of ACSR conductor/earth wire of any size/type from pole by taking proper shutdown. |
| 2 | Dismantling insulators any type, any size from pole/wall. |
| 3 | Supply, laying and testing , LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 95 sq. mm 3.5 core, confirming to IS -7098 Part-I complete all as specified |
| 4 | Supply, laying and testing, LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 70 sq. mm 3.5 core, confirming to IS -7098 Part-I complete all as specified |
| 5 | Supply, laying and testing, LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 50 sq. mm 3.5 core, confirming to IS -7098 Part-I complete all as specified |
| 6 | Supply, laying and testing, LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 35 sq. mm 3.5 core, confirming to IS -7098 Part-I complete all as specified |
| 7 | Supply, laying and testing, LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 25 sq. mm 4 core, confirming to IS -7098 Part-I complete all as specified |
| 8 | Supply, laying and testing, LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 16 sq. mm 4 core, confirming to IS -7098 Part-I complete all as specified |
| 9 | Supply, laying and testing, LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 10 sq. mm 2 core, confirming to IS -7098 Part-I complete all as specified |
| 10 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil for laying of cable, pole foundation, stay, laying of pipe etc complete all as specified and directed. |
| 11 | All as per item No. 19 here-in-before but depth exceeding 1.5 mtr and not exceeding 3 mtr. |
| 12 | M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable punned down to 18 cm complete all as specified and directed. Note :- Punned thickness 18 cm shall be measured for payment. |
| 13 | M&L for Brick covering with width equal to length of brick as mechanical protection to cable with well burnt sub class 'B' bricks laid as directed. |
| 14 | Returning filling including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 15 | Removing excavated soil to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 16 | Supply, installation, commissioning & testing, factory made bus bar chamber of size 120x75x45cm made out of 14 SWG CRCA sheet , powder quoted weather proof outdoor type with RAL 7032 (siemens grey) with front and rear openable double door with loocking arrangement and aluminium strip of size 50x6mm-04 Nos (75Cm of 200Amp) with 63 Amps 16KA 4 Pole MCCB, 01 Nos. alongwith spreaded link for connection, including the panel shall be mounted on frame made out of 40x40x6mm angle iron with 600mm long legs grouted in PCC 1:3:6 complete all as specified and directed by Engg-in-charge. |
| 17 | Earthing complet with galvanised steel earth plate eletrode 60xm x 60cm x6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised iron earth lead 32x6mm size, by means of bolts, nuts, check buts and washers of galvanised iron and earth lead protected by provision of GI medium grade pipe 40mm bore including provision of aggregates with 40mm thick cover of RCC (1;2:4) reinfored with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, common salt and charcoal filling, with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning filling in distance not exceeding 50 mtr and removal of surlus soil complete all as per plate No 3 of SSR-2009 Part-I and connecting to existing earth test point all as specified or indicated including testing on completion. |
| 18 | S&F street light fixture ≥90 watt LED with pressure die cast aluminium housing with toughened glass having IP-66 degree of protection, individual LED's must have secondary lense for better throw across and along the road, with system luminarie efficacy ≥100 lumen/watt, colour rending index(CRI) of ≥ 70, co-related colour temperature (CCT) of 5700K. Luminaire should have surge protection upto 05 KV and having additional surge protection upto 10 KV for driver, PF ≥ 0.9 and THD ≤10% , operating voltage range from 140 to 270 volt, The potted driver used shall be a constant curent driver with efficiency of ≥ 85%.The manufacturers LOGO shall be engraved into housing of luminaire. BAJAJ,Philips,Havells ,Wipro . |
| 19 | S&F bracket for fixing of street light fittings bend to shape, made out of 25 mm dia GI pipe medium grade upto 1.5 mtr long fixed with and including two sets of MS clamp made out of Flat iron of size 50x6 mm, fabricated to shape and fixed with nuts, bolts & washers & two coats of aluminum paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge. |
| 20 | S&F single run of PVC insulated and PVC Sheathed cable HR with copper conductor of size 3 core x 1.5 sqmm & necessary conduit pipe of size 20mm for protection from wind/sunlight proper clamping etc from JB to bracket of streetlight copper conductor cable of size 1.5 sqmm threecore all as required and specified by Engr-in-Charge |
| 21 | M & L for steel pole and providing new steel tubular swaged pole complete with 6 mm thick mild steel base plate, finial taper plug, bolts, nuts and screws as specified type 410-SP-31 (9 Mtr long) including drilling of holes in poles and provision of hooks for continuous GI earth wire and providing two coats of aluminium paint over a coat of red oxide primer, including marking pole number etc. with 8 cms letter with black paint having around yellow painted circle of 10 cms dia as directed. Note:- Earth work and PCC shall be measured and paid for separately. |
| 22 | M&L for providing Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in coping, cable duct, cover slab and benching including all necessary form work complete all as specified and directed. |
| 23 | M&L for providing PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete all as specified and as directed. |
| 24 | S&F sub Main Wiring with two run PVC insulated unsheathed multistrand FRLS-H flexible copper conductor cable of size 2x6 sqmm and one PVC insulated multistrand unsheathed FRLS-H flexible copper conductor cable of size 6 sqmm (green colour) as earthing lead connecting to main earthing dolly drawn in and including non metallic PVC concealed conduit 20mm dia complete and making good to disturbed surface complete of wall/floor with cement mortar and finishes to match the existing surface complete all as specified and directed. |
| 25 | S&F factory made sheet metal enclosures vertical load line distribution boards, double door made out of CRCA mild steel sheet, with insulating material like polyester epoxy coated surface mounting three phase 415 volts 4 ways vertical TPN DB for comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following (a) MCCB Three POLE 63 AMPS AC 415 VOLTS 25 KA=01 Nos fixed type as incoming and 03 Nos. MCB SPN 20 Amps, C series as outgoing. ( (i) MCCB, MCB and DB should be of same make. |
| 26 | M&L for thermoplastic cable junction boxes IP 65 weather proof for outdoor installation (with knockouts for cable entry) the junction box shall be insulated and made out of polycorboante with glass fiber reinforced. The size in mm should not be less than 210x260x117. JB should be with one 6Amp SP and terminal/busbar set assemble by OEM. |
| 27 | M&L for pole mounted junction box made out of 18 gauge MS sheet front opening shutter with locking aggangement including fixing accessories such as clamp, nuts and bolts etc including two coats of aluminium paint over a coat of red oxide primer of size min 20x15x10 Cm comprising of 04 strips 63 Amps aluminium bus bar with MCB SP 06 Amps complete all as specified and directed by Engr-in-Charge |
| 28 | S&F automatic street light timer switch three phase, suitable to take load of minimum 3 KW, 415 Volts based on weather proof photoelectric timer adjustable upto min 10 lux, alongwith suitable power contactor & TPN MCB 20 Amp on both input and output duly prewired with suitable size of copper wiring with proper lugs and terminal blocks with facility of manual ON/OFF switch complete enclosed in polycarbonate IP-66 enclosure shock, rust, weather & termite proof uv-resistant, FR grade fixed on pole with MS strip of size 20x2mm complete all as specified and as directed. |
| 29 | Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 18,800.00 and any other reduction if any from quoted amount. Please Enable Macros to View BoQ information |