| 1 | M&L for Demolition and breaking up 150 mm internal dia drain pipes (Salt glazed ware, AC or Reinforced concrete) incl PCC bedding & hauching set in cement morter of above dia pipe Complete all as specified and directed. |
| 2 | M&L for Demolition and breaking up 200 mm internal dia drain pipes (Salt glazed ware, AC or Reinforced concrete) incl PCC bedding & hauching set in cement morter of above dia pipe complete all as specified and directed. |
| 3 | Supply, laying & jointing 150 mm nominal bore (Internal Diameter) DWC (HDPE Double Wall Corrugated) Pipe, socketed & sewage pipe having 6.00 metre length, conforming to IS : 16098 (Part-II) of SN-4 Stiffness with & including necessary jointing materials etc complete all as specified & directed. |
| 4 | Supply, laying & jointing 200 mm nominal bore (Internal Diameter) DWC (HDPE Double Wall Corrugated) Pipe, socketed & sewage pipe having 6.00 metre length, conforming to IS : 16098 (Part-II) of SN-4 Stiffness with & including necessary jointing materials etc complete all as specified & directed. |
| 5 | M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150 mm internal dia of pipe complete all as specified and directed. |
| 6 | M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 200 mm internal dia of pipe complete all as specified and directed. |
| 7 | M&L for Cement Concrete bed Type C-2, 1:3:6 (using 40 mm graded stone aggregate) to 150 mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified & directed. |
| 8 | M&L for Cement Concrete bed Type C-2, 1:3:6 (using 40 mm graded stone aggregate) to 200 mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified & directed. |
| 9 | M&L for Salt glazed stone ware gully traps size 150 x 150 mm, square or round mouthed, type ‘P’ including setting and jointing to drains with cement mortar 1:1 including demolition of existing traps complete all as specified and directed. |
| 10 | M&L for Excavating in trenches in soft/loose soil, not exceeding 1.5 metre wide & not exceeding 1.5 metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan & getting out complete all as specified & directed. |
| 11 | M&L for Excavating in trenches in soft/loose soil, not exceeding 1.5 metre wide & exceeding 1.5 metre & not exceeding 3.0 metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan & getting out complete all as specified & directed. |
| 12 | M&L for Returning, filling in soft/loose soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified & directed. |
| 13 | M&L for Removing surplus excavated material (soil) to a distance exceeding 250 metre but not exceeding 500 metre & depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified & directed. |
| 14 | Material and labour for cement concrete type B1, 1:2:4 (20mm graded stone aggregate in coping and the like including weathering, slightly rounded or chamfered angles and throating as directed complete all as specified. |
| 15 | Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework & precast concrete articles complete all as specified and directed. |
| 16 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 17 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces of wall in CM 1:4 and to be finished even and smooth (without using extra cement) complete all as specified and directed. |
| 18 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified & directed. |
| 19 | S&F of Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 20 | Demolition of Cement Concrete (reinforced) of any description & in any position not otherwise specifically provided for complete all specified and directed. |
| 21 | M&L for Providing Precast Cement Concrete Type B-1, 1:2:4 using 20mm graded stone aggregate in landings, cover slabs (for manholes etc.), chullah hoods, chajjas, water troughs, mangers, shelves & similar articles with plain faces including necessary chamfers, weatherings, throating etc. & setting in 1:6 cement mortar including necessary formwork if required complete all as specified & as directed. |
| 22 | M&L for unplasticised PVC pipe 110mm dia type B with wall thickness 4mm (min) of pressure rating 4KN/sqm laid in trenches/ floor and jointed with cement solvent including testing complete all as specified and directed |
| 23 | M&L for unplasticised PVC pipe 75mm dia type B laid in trenches/ floor and jointed with cement solvent including testing complete all as specified and directed |
| 24 | S&F PVC (SWR) bends ISI marked any radius of 110 mm bore with access door complete all as specified and directed. |
| 25 | S&F PVC (SWR) bends ISI marked any radius of 75 mm bore with access door complete all as specified and directed. |
| 26 | S&F PVC (SWR) junction single, (single T) equal or un equal of 110 mm bore of pipe complete all as specified and directed |
| 27 | S&F PVC (SWR) junction single, (single T) equal or un equal of 75 mm bore of pipe complete all as specified and directed |
| 28 | Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for complete all specified and directed. |
| 29 | M & L for Plain Cement Concrete Type 1:4:8 Type D2 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 30 | M & L for Plain Cement Concrete Type 1:3:6 Type C2 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 31 | M&l for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams;and similar work; vertical or to batter complete all as specified and directed. |
| 32 | M&L for Reinforced Cement Concrete Type M-30 using 20 mm graded granite stone aggregate) in foundations including rafts, footings and mass concrete. |
| 33 | M&l for Formwork to faces of walls,retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all as specified and directed. |
| 34 | M&L for Reinforced Cement Concrete Type M-30 Walls, retaining walls,basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed. |
| 35 | M&l for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 36 | M&l for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed. |
| 37 | S&F Mild Steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking , bending, hooking etc and binding with MS wire 0.9mm dia(annealed) complete all as specified |
| 38 | S&F Mild Steel TMT bars 6 to 8mm mm dia and over, cut to length, bent to shape required, including cranking , bending, hooking etc and binding with MS wire 0.9mm dia(annealed) complete all as specified |
| 39 | M&L for Reinforced Cement Concrete Type M-30 as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 40 | M&L for Brickwork with old size flyash bricks, straight or curved on plan exceeding 6m mean radius, built in 1:4 cement mortar complete all as specified & directed. |
| 41 | M&L for Brickwork with fly ash bricks in one brick thick honey-comb walling, built in 1:4 cement mortar complete all as specified & directed. |
| 42 | M&L for 15mm thick cement plaster in CM 1:4 on fair faces of brick or concrete surfaces using WPC where ever required as per manufacturerer's instructions and finishing the surface even and smooth without using extra cement complete all as specified and directed. NOTE -WPC shall be measured and paid separetely. |
| 43 | Supply only water proofing compound complete all as specified and directed. |
| 44 | S&F MS framed work such as grills,gratings, etc with ends of bars shouldered and / or riveted or forged into spikes; framed guard ; barred iron doors; ladders ; framed balusters; walk ways; railing and simillar work Con-forming to Fe 290 Gde E-165 complete all as specified and directed. |
| 45 | M&L for PCC 1:3:6 type C-1 using 20mm graded stone agg for PCC band complete all as specified and directed. |
| 46 | M&L for Loose filling with aggregates of gauge 80 to 150mm in soakage pits, soakage wells complete all as specified and directed. |
| 47 | M&l for Formwork to soffits of curved suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) |
| 48 | M&L 150 mm dia Salt-glazed stoneware drain pipes laid in trenches and jointed complete all as specified and directed. |
| 49 | M&L 450 mm dia Cast Iron Manhole cover Including Frame Complete all as specified and directed. |
| 50 | Setting in cement mortar 1:3 and flaunching with cement concrete 1:2:4 type B-l cast iron manhole covers and frames, medium duty, any type and size complete all as specified and directed. |
| 51 | M&L for PCC 1:4:8 type D2, 75mm thick using 40mm graded aggregate as in sub base complete all as specified and directed. |
| 52 | M&L factory made 60 mm thick rubber moulded glossy finish machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of M-35 grade including 50mm thick sand cushion and filling the voids of paver blocks/tiles with dry sand complete all as specified & directed. |
| 53 | S&F factory made rubber moulded glossy finished Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors over 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 54 | Schedule of credit amount of Rs 390129.60 to be deducted during AOC Please Enable Macros to View BoQ information |