| 1 | Taking down carefully copper /aluminium point wiring (light, fan socket or power) through stove enamelled steel conduit/pvc conduits including complete fittings such as switches, ceiling roses, pendants, regulators, sockets,, switch sockets, electrical fittings etc removing and making good disturbed surfaces of walls/ceiling etc, complete all as specified and directed. |
| 2 | M & L concealed point wiring with 1.5 Sqmm single core, multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable in concealed PVC , ISI marked including all accessories as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed FRLSH copper wire, ISI marked of green colour for continous earth, including sunken box made out of suitable thick and not less than 60 mm in depth GI/MS/ pressed steel terminal box to be concealed in wall, duly painted including laminated hylum/maonite sheet cover thickness 3mm for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer complete all as specified and directed for the following :-Note : Wiring to be done as per approved colour code.(a). One light /fan/ call bell point controlled by one switch. |
| 3 | (b) One 5 pin socket outlet 5 Amps on independent board |
| 4 | (c) One 5 pin socket outlet 5 Amps on same board |
| 5 | (d) One light point controlled by 2 way switch SP, 5 Amp, 240 Volts |
| 6 | All as per item No 2 above but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FRLSH PVC insulated sheathed cable with FRLSH PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent board, complete all as specified and directed. |
| 7 | M & L for point wiring with 1.5 Sqmm single core, multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in and including casing caping of 25 mm wide, with double locking type, ISI marked including all accessories casing caping as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed FRLSH copper wire, ISI marked of green colour for continous earth, including sunken box made out of suitable thickness and not less than 60 mm in depth GI/MS/ prssed steel terminal box to be conclead in wall, duly painted including 3mm hylum /masonite sheet cover, for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer complete all as specified and directed. Note : Wiring to be done as per arroved colour code. |
| 8 | All as per item no. 4 but One light point controlled by 2 way switch SP, 5 Amp, 240 Volts |
| 9 | All as per item no. 4 above but one 5 amp socket point on same board |
| 10 | All as per item no. 4 above but one 5 amp multi socket indepenedent |
| 11 | All as per item No. 4 hereinbefore, but using 2.5 sqmm ( nominal area) multistranded FRLSH copper conductor cable/wire & 2.5 sqmm size PVC insulated unsheathed copper conductor cable for earth continuity ( green colour) for one 5 pin socket outlet 5 / 15 Amp multi purpose independent point controlled by 15 Amp switch, SP one way, 240 Volts & Socket, complete all as specified and directed. |
| 12 | All as per item No. 4 hereinbefore, but using 4 sqmm (nominal area) FRLSH multistranded copper conductor cable/wire for one 5/15 Amp socket point controlled by 15 Amp switch, SP one way 240 Volts & Socket, complete all as specified and directed. |
| 13 | M & L for Point wiring with PVC insulated unsheathed electric cable 1100 volts grade, single core, FRLSH cable having multistranded copper conductor of 1.5 Sqmm nominal cross sectional area, ISI marked, drawn in existing concealed conduit with 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor FRLSH cable, ISI marked as continuous earth conductor connected to earth dolly by providing suitable lugs including 3.0 mm new laminated hylum sheet /masonite sheet cover cover of min thick , ISI marked of Make\\" Hylem\\" of suitable sizes to be fixed/ mounting on existing MS/ GI sunkun boxes for mounting of fittings like switches, sockets, fan regulators etc fixed with galvanised screw and cup washer. complete all as specified and directed for the following:- Note : Wiring to be done as per arroved colour code. |
| 14 | (b) One fan/exhaust fan point controlled by one switch |
| 15 | (c) One 5 pin socket outlet 5 Amps on same board |
| 16 | (d) One 5 pin socket outlet 5 Amps on independent board |
| 17 | (e) One light point controlled by 2 way switch SP, 5 Amp, 240 Volts |
| 18 | All as per item No. 10 above but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FRLSH PVC insulated sheathed cable with FRLSH PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent board, complete all as specified and directed. |
| 19 | Supply and fix in repair / replacement of modular switch, 1 module, 6 amp one way, ISI marked complete all specified and directed. |
| 20 | Supply and fix in repair / replacement of modular switch, 1 module, 16 amp one way complete all specified and directed. |
| 21 | Supply and fix in repair / replacement modular socket 2 module universal type 6/16 amp one way complete all specified and directed. |
| 22 | Supply and fix in repair / replacement modular socket 2 module universal type 5/6 amp one way complete all specified and directed. |
| 23 | Supply and fix in repair / replacement modular bell push 6A 1 module complete all as specified and directed. |
| 24 | S & F in repair / replacement Bell buzzer, ding dong AC,230V, 50hz single pole complete all as specified and directed all specified and directed. |
| 25 | S & F ceiling rose PVC / polycarbonate, isolated body surface Bakelite 65mm dia three terminals complete all as specified and directed. |
| 26 | S & Fin repair / replacement of switch piano flush button single pole one way, 6 Amp (ISI marked) complete all as specified and directed. by Engineer-in-Charge. |
| 27 | S & F in repair /replacement Switch socket outlet 2 in 1, 3 pin, 6 Amp flush type (ISI marked) complete all as specified and directed by Engineer-in-Charge. |
| 28 | S & F in repair /replacement Socket outlet 2 in 1, 3 pin, 6 Amp flush type (ISI marked) complete all as specified and directed by Engineer-in-Charge. |
| 29 | S & F in repair /replacement Switch bell push flush type 5 Amp (ISI marked) all as per complete all as specified and directed. |
| 30 | S & F in repair /replacement Switch socket combination outlet 15 Amp, 5-in-1, controlled by one switch (ISI marked) complete all as specified and directed. |
| 31 | S & F in repair / replacement Switch flush button, single pole two way, 6 Amp (ISI marked) complete all as specified and directed. |
| 32 | S & F in repair / replacement of socket type EME fan 5 step regulator switch/socket type for ceiling fan of suitable size, complete all as specified and directed. |
| 33 | S & F in repair / replacement Lamp holder / angle holder insulated body with black / white plate for batten fittings, complete all specified and directed |
| 34 | Supply and fix in repair / replacement of modular step type fan regulator 120 watt, AC, 220V, 50hz, ISI marked complete all specified and directed |
| 35 | Supply and fix in repair / replacement modular switch 1 module 6 amp one way ISI marked complete all specified and directed. |
| 36 | Supply and fix in repair / replacement modular switch 1 module 16 amp one way complete all specified and directed. |
| 37 | Supply and fix in repair / replacement modular socket 2 module universal type 5/6 amp one way complete all specified and directed. |
| 38 | Supply and fix in repair /replacement modular socket 2 module universal type 6/16 amp one way complete all specified and directed. |
| 39 | Supply and fix in repair / replacement modular bell push 6A 1 module complete all as specified and directed. |
| 40 | S & F in repair / replacement Bell buzzer, ding dong AC,230V, 50hz single pole complete all as specified and directed. |
| 41 | Supply and fix in repair / replacement modular cover plates with frame up From 1 /2 to 3 module as per site requirements complete all as specified and directed. |
| 42 | Supply and fix in repair / replacement modular cover plates with frame up from 4 to 12 module as per site requirements complete all as specified and directed. |
| 43 | Supply and fix in repair / replacement modular metal flush box as per site requirements from 1/2 to 3 modules complete all as specified and directed. |
| 44 | Supply and fix in repair / replacement modular metal flush box as per site requirements from 4 to 12 modules complete all as specified and directed. |
| 45 | M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 4.0 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25mm dia/casing capping/ suitable size , ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 4.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surfaces/ recess, including taking down of old unserviceable sab mains, complete all as specified and directed. |
| 46 | M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 6.0 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25mm dia/casing capping/suitable size, ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess including taking down of old unserviceable sab mains, complete all as specified and directed. |
| 47 | M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 10.0 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25mm dia/casing capping/suitable size, ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 10.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess including taking down of old unserviceable sab mains, complete all as specified and directed. |
| 48 | M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 4.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping/suitable size, including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 4.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly including taking down of old unserviceable sab mains, complete all as specified and directed. |
| 49 | M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 6.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping/suitable size, including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly including taking down of old unserviceable sab mains, complete all as specified and directed. |
| 50 | M&L for Sub main wiring with four runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 6.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping/suitable size, including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly including taking down of old unserviceable sab mains, complete all as specified and directed. |
| 51 | M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 10.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly including taking down of old unserviceable sab mains, complete all as specified and directed. |
| 52 | M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 2.5 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 20mm dia/casing capping/suitable size , ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 2.5Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surfaces/ recess including taking down of old unserviceable sab mains, complete all as specified and directed. |
| 53 | M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 2.5 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping/suitable size, including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 2.5 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly including taking down of old unserviceable sab mains, complete all as specified and directed. |
| 54 | M&L cutting of wall/ceiling/column for laying submain of any size including plastering ,white wash all specified and directed in charge. |
| 55 | Supply and fixing LED building security light fitting with suitable size bracket/angle with three core flexible wire to fit security light of 45 w IP 66 protection LED. All specified and directed in charge |
| 56 | Supply and fix of LED batten with 20/22W LED tube light in wall/surface connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as directed by Engr-in-charge. |
| 57 | Supply and fix in repair / replacement LED batten with 24W LED tube light in wall/surface connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as directed by Engr-in-charge. |
| 58 | S&F double door MCB DB made out of 18 SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 12 way double door open able, including taking out old unserviceable MCB DB of any size/type, complete all as specified and directed. |
| 59 | S&F double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 8 way double door open able, including taking out old unserviceable MCB DB of any size / type, complete all as specified and directed. |
| 60 | S&F double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 4 way ,including taking out old unserviceable MCB DB of any size/type complete all as specified and directed.. |
| 61 | S&F double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 2 way including taking out old unserviceable MCB DB of any size/type complete all as specified and directed.. |
| 62 | S&F double door MCB VTPN DB 4 WAY made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 4 way, including taking out old unserviceable MCB DB of any size/type, complete all as specified and directed.. |
| 63 | S&F double door MCB TPN DB 4 WAY made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 4 way ,including taking out old unserviceable MCB DB of any size/type, complete all as specified and directed.. |
| 64 | S&F double door MCB VTPN DB 8 WAY made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 4 way ,including taking out old unserviceable MCB DB of any size/type, complete all as specified and directed.. |
| 65 | S&F in repair/replacement 6 to 32 AMP MCB single pole 240 V 10 KA (C-Series) complete all as specified and directed. |
| 66 | S&F in repair/replacement SPN 32 AMP MCB DP 240 V 10 KA (C-Series) complete all as specified and directed. |
| 67 | Supply and fix LED recess surface mounted 2x2 luminarie 36w fitting, 220 V, AC,50HZ suitable surge protection, high power factror,driver etc complete including flexible wire and connected accessories all as specified and directed by engr-in-charge. |
| 68 | Supply and fix LED Bulk head fittings 9/10W luminaire including LED light driver holder 220 V, AC,50HZ connecting up with three core flexible copper conductor calbe of suitable size complete with all acccessories complete all as specified and directed by engr-in-charge. |
| 69 | S & F in repair /replacement of LED tube rod 20 watt, 220V,AC,50HZ change with existing any tube rod including flexible wire and connected accessories complete all as specified and directed. |
| 70 | S & fix in repair /replacement of Batten MS suitable for 18/22/24W LED rod 220V, AC, 50HZ with accessories including suitable 1.5 sqmm 2 core wire for connecting with ceiling rose complete all as specified and directed. |
| 71 | Supply and fix in repair /replacement of LED batten 10w, 2 feet with LED tube light 220V,AC,50HZ in wall/surface connecting with all required accessories like flexible cable from ceiling rose etc complete all as specified and directed. |
| 72 | S&F in repair /replacement of MCCB 4 pole, thermal magnetic release range 500 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed. |
| 73 | S & F in repair /replacement of MCCB 4 pole, thermal magnetic release range 400 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed. |
| 74 | S & F in repair /replacement of MCCB 4 pole, thermal magnetic release range 200 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed. |
| 75 | S & F in repair /replacement of MCCB 3 pole, thermal magnetic release range 40-63 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed. |
| 76 | S & F in repair /replacement of MCCB 4 pole, thermal magnetic release range 100 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed. |
| 77 | S & F in repair /replacement of MCCB 4 pole, thermal magnetic release range 125 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed. |
| 78 | M& L for attending daily complaint and checking & repairing of DBs / meter panel board / circuits / submain wiring / switches / sockets etc and other connected work and make it functional including rectification of faults complete all as directed by Engr-in-Charge.Note:- Attending one complaint and make it functional shall be measured as on Job. |
| 79 | S & F in repair /replacement of MCCB 4 pole, thermal magnetic release range 63 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed. |
| 80 | S & F in repair /replacement of MCCB 4 pole, thermal magnetic release range 40 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed. |
| 81 | Taking out cover plate of bus conductor duct of multistoreyied building, inspection cleaning, servicing including replacement of rusted nuts bolts,insulators etc., cutting of damage end of outgoing cables and reconnection using proper size of cable lugs and preparation of old painted surface by scrapping and brooming down and material and labour for two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed by Engr-in-Charge. |
| 82 | Supply and fix in repair /replacement of three pin top of capacity 15 amp ,AC, 220 V complete all as specified and directed. |
| 83 | Supply and fix in repair /replacement of PCRD plug of capacity 15 amp ,AC, 220 V complete all as specified and directed. |
| 84 | Supply and fix epoxy coated connector of capacity 100A post type for bus bar trunking system complete all as directed by Engr-in-charge. Please Enable Macros to View BoQ information |
| 85 | Supply and fix epoxy coated connector of capacity 100A post type for bus bar trunking system complete all as directed by Engr-in-charge. Please Enable Macros to View BoQ information |