| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | All kinds of soil |
| 3 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : |
| 4 | All kinds of soil |
| 5 | Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 8 | 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 10 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 11 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 12 | Providing sand stone slab for roofing and laying them in cement mortar 1 : 4 (1 cement : 4 coarse sand) over wooden karries or R.C.C. battens or structural steel sections (Karries or battens or structural steel sections to be paid separately), including pointing the ceiling joints with cement mortar 1:3 (1 cement : 3 fine sand ) complete : |
| 13 | White sand stone slab |
| 14 | 40 to 50 mm thick |
| 15 | Providing and fixing on wall face unplasticised Rigid PVC rain water/soil waste pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes. |
| 16 | 160 mm diameter |
| 17 | 12 mm cement plaster of mix : |
| 18 | 1:6 (1 cement: 6 coarse sand) |
| 19 | 15 mm cement plaster on rough side of single or half brick wall of mix : |
| 20 | 1:6 (1 cement: 6 coarse sand) |
| 21 | Neat cement punning. |
| 22 | Cleaning of cholked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm |
| 23 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 24 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 25 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 26 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: |
| 27 | 150 mm diameter S.W. pipe |
| 28 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality |
| 29 | L D- 2.5 |
| 30 | Rectangular shape 600x450 mm internal dimensions |
| 31 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : |
| 32 | For pipes 100 to 250 mm diameter |
| 33 | Disposal of liquid sludge received from septic tank/manholes by diesel running vehicle mounting hydraulic operated high pressure suction machine fitted with pump having 3000 litres suction capacity tank including skilled operator, supervising engineer etc. to municipal dumping ground at a distance approximately 5.0 Km all complete as per direction of E-I-C. Please Enable Macros to View BoQ information |