| 1 | Supply and fixing in replacement of lead acid battery sealed maintenance free battery (make Exide/Luminous/Amaron) with insulation Film/Gar Film for every battery and IR test of the battery carried out before instaltion. incl testing and commissioning complete all as specified and directed by Engr-in-Charge for battery of following capacity :- |
| 2 | Battery 12 V 65 Ah for 20 KVA UPS |
| 3 | Battery 12 V 42 Ah for 20 KVA UPS |
| 4 | Battery 12 V 100 Ah for 30 KVA UPS |
| 5 | Battery 12 V 65 Ah for 30 KVA UPS |
| 6 | Supply, Installation, test and Commissioning in replacement of indoor cubical type LT panel board, suitable for 415V, 3 phase, 4 wire 50 Hz, AC supply system fabricated from stainless steel (SS 304) totally enclosed, dust, weather & vermin proof, 3.15 mm thick having 4 pole aluminium busbar of rating 1.5 times that of controlling MCCB supported on SMC insulators with short circuit withstand capacity 35 MVA for I second, bottom base channel of MS section not less than 100 mm x 50 mmx 5 mm thick, entire panel shall have a common aluminium earth bar of size 25 mm x 5 mm at the rear with 2 Nos earth stud, solid connections from main bus bar to switch gears with required size of copper bus bars and conrol wiring with min 1.5 sqmm PVC insulated copper conductor cable, cable alleys, cable gland plates in two half including tamper proof digitel energy meter to measure voltage, current, PF, KWH, KVAH, KVARH, Digital multifuctional display meter, phase indication lamp & its connection and mounted on suitable PCC foundation with following detailed specificatons & controls complete all as specified and directed by Engr-in-Charge :- (UPS Panel at old server room)INCOMING(a) MCCB 4 Pole 320 amp 50 Hz, 415 V, 35 KA (Icu=Ics=100%), thermally adjustable between 60 to 100% - 03 No (one for each UPS)OUTGOING(a) MCCB 4 Pole 500 amp 50 Hz, 415 V, 35 KA (Icu=Ics=100%), thermally adjustable between 60 to 100% - 02 No (for I/c)(b) MCCB 4 Pole 200 amp 50 Hz, 415 V, 35 KA (Icu=Ics=100%), thermally adjustable between 60 to 100% - 06 No (for o/c)(c) MCCB 4 Pole 160 amp 50 Hz, 415 V, 35 KA (Icu=Ics=100%), thermally adjustable between 60 to 100% - 05 No (for o/c)(d) MCCB 4 Pole 125 amp 50 Hz, 415 V, 35 KA (Icu=Ics=100%), thermally adjustable between 60 to 100% - 05 No (for o/c) |
| 7 | Supply, installation, testing and commissioning outdoor cubical type panel board, suitable for 415V, 3 phase, 4 wire, 50 Hz, AC supply system fabricated from stainless steel (SS 304) totally enclosed, dust, weather & vermin proof, 2 mm thick having 4 pole aluminium busbar of rating 1.5 times that of controlling MCCB supported on SMC insulators with short circuit withstand capacity 35 MVA for 1 second, bottom base channel of MS section not less than 100 mm x 50 mmx 5 mm thick, entire panel shall have a common aluminium earth bar of size 25 mm x 5 mm at the rear with 2 Nos earth stud, solid connections from main bus bar to switch gears with required size of copper bus bars and control wiring with min 1.5 sqmm PVC insulated copper conductor cable, cable alleys, cable gland plates in two half, Digital multifuctional display meter, phase indication lamp, power contactor & its connection and mounted on suitable PCC foundation with following controls complete all as specified and directed by Engr-in-Charge:- Incoming(a) One number MCCB 4 Pole 400 amp 50 Hz, 415 V, 35 KA (Icu=Ics=100%) thermally adjustable between 60 to 100%Outgoing(a) MCCB 4 Pole 250 amp 50 Hz, 415 V, 25 KA (Icu=Ics=100%), thermally magnatic release adjustable type-01 No(b) MCCB 4 Pole 100 amp 50 Hz, 415 V, 16 KA (Icu=Ics=100%), thermally magnatic release- 5 Nos(c) MCCB 4 Pole 63 amp 50 Hz, 415 V, 16 KA (Icu=Ics=100%), thermally magnatic release- 2 Nos(d) MCB 4 pole 40 amp 50 Hz, 415, 10 KA, 'C' series-2 Nos(e) Astronomical, Multifunctional time swithces-1 Nos |
| 8 | Supply, installation, testing and commissioning in replacement of indoor cubical type panel board, suitable for 415V, 3 phase, 4 wire, 50 Hz, AC supply system fabricated from stainless steel (SS 304) totally enclosed, dust, weather & vermin proof, 2 mm thick having 4 pole aluminium busbar of rating 1.5 times that of controlling MCCB supported on SMC insulators with short circuit withstand capacity 35 MVA for 1 second, bottom base channel of MS section not less than 100 mm x 50 mmx 5 mm thick, entire panel shall have a common aluminium earth bar of size 25 mm x 5 mm at the rear with 2 Nos earth stud, solid connections from main bus bar to switch gears with required size of copper bus bars and control wiring with min 1.5 sqmm PVC insulated copper conductor cable, cable alleys, cable gland plates in two half, Digital multifuctional display meter, phase indication lamp, power contactor & its connection and mounted on suitable PCC foundation with following controls:- (Pump Panel)Incoming:-One number MCCB 4 Pole 160 amp 50 Hz, 415 V, 35 KA (Icu=Ics=100%) thermally adjustable between 60 to 100%Outgoing:-(a) MCCB 4 Pole 125 amp 50 Hz, 415 V, 25 KA (Icu=Ics=100%), thermally magnatic release adjustable type-02 No(b) MCCB 4 Pole 63 amp 50 Hz, 415 V, 16 KA (Icu=Ics=100%), thermally magnatic release- 1 Nos(c) MCCB 4 Pole 40 amp 50 Hz, 415 V, 16 KA (Icu=Ics=100%), thermally magnatic release- 1 Nos(d) MCB 4 pole 40 amp 50 Hz, 415, 10 KA, 'C' series-2 Nos Please Enable Macros to View BoQ information |
| 9 | Supply, installation, testing and commissioning in replacement of indoor cubical type panel board, suitable for 415V, 3 phase, 4 wire, 50 Hz, AC supply system fabricated from stainless steel (SS 304) totally enclosed, dust, weather & vermin proof, 2 mm thick having 4 pole aluminium busbar of rating 1.5 times that of controlling MCCB supported on SMC insulators with short circuit withstand capacity 35 MVA for 1 second, bottom base channel of MS section not less than 100 mm x 50 mmx 5 mm thick, entire panel shall have a common aluminium earth bar of size 25 mm x 5 mm at the rear with 2 Nos earth stud, solid connections from main bus bar to switch gears with required size of copper bus bars and control wiring with min 1.5 sqmm PVC insulated copper conductor cable, cable alleys, cable gland plates in two half, Digital multifuctional display meter, phase indication lamp, power contactor & its connection and mounted on suitable PCC foundation with following controls:- (Pump Panel)Incoming:-One number MCCB 4 Pole 160 amp 50 Hz, 415 V, 35 KA (Icu=Ics=100%) thermally adjustable between 60 to 100%Outgoing:-(a) MCCB 4 Pole 125 amp 50 Hz, 415 V, 25 KA (Icu=Ics=100%), thermally magnatic release adjustable type-02 No(b) MCCB 4 Pole 63 amp 50 Hz, 415 V, 16 KA (Icu=Ics=100%), thermally magnatic release- 1 Nos(c) MCCB 4 Pole 40 amp 50 Hz, 415 V, 16 KA (Icu=Ics=100%), thermally magnatic release- 1 Nos(d) MCB 4 pole 40 amp 50 Hz, 415, 10 KA, 'C' series-2 Nos Please Enable Macros to View BoQ information |