| 1 | Labour and T&P to maintain water quality of swimming pool, 2.25 lakh gallons capacity by mixing alum, soda ash, copper sulphate, chlorine CD-999/TCCA-90 granular disinfectant of best quality as required to maintain the quality of water such as clarity, PH value 7.2 to 7.6, residual chlorine of 0.8 to 1 PPM. The contractor will be responsible for daily removing unwanted materials and cleaning of swimming pool & fungus from floor & side walls with the help of suction sweeper and nylone brush all as directed. The contractor will also be responsible to improve the environment of installation, daily cleaning and removing grass from the surrounding area of swimming pool and installation complete all as specified and directed.NOTE:-(i) Alum, soda ash, copper sulphate, chlorine TCCA-90 granular disinfectant, spa clarified & acid will measured & paid separatly.(ii) If the quality of water as mentioned above is not maintained by the contractor a penal recovery of Rs 2000/day shall be made for the same. |
| 2 | Supply only alum (aluminium sulphate) conforming to IS-260 used as a coagulating agent/floculant to remove unwanted particles colour and turbidity from pool water complete all as specified and directed. |
| 3 | Supply only soda ash (sodium carbonate) conforming to IS-251 used to raise PH value of pool water complete all as specified and directed. |
| 4 | Supply only copper sulphate in granules form of size 2mm to 4mm (bright blue triclinic crystal) conforming to IS-261 to remove algae in pool water complete all as specified and directed. |
| 5 | Supply only TCCA Chlorine granules having 90% chlorine used a disinfectant algicide and bactericide agent for pool water complete all as specified and directed. |
| 6 | Supply only crystal bright & spa clarifier and conditioner in blue colour completely soluble in water used as flocculant for co-ogulating the small particles such as fine dust, oils, micro organism contaminants in pool water to make the pool water crystal clean all as specified and directed. |
| 7 | Supply only concentrated Suphuric Acid (H2SO4) conforming to IS 266 required to reduce the PH & alkanity of pool water complete all as specified and directed. |
| 8 | S&F in repair PVC hose pipe heavy duty 50mm dia suitable for suction sweeper complete all as specified and directed. |
| 9 | S&F in repair of nylon rope 25mm dia complete all as specified and directed. |
| 10 | S&F in repair nylon brushes of suction sweeper of existing size and as per sample 3 feet long complete all as specified and directed. |
| 11 | S&F in repair PVC float valve heavy duty of 200mm dia suitable for to hold PVC hose pipe in water including fixing arrangement complete all as specified and directed. |
| 12 | M&L for in replacement of gland packing to stop leakage of water from pumps/sluice valves complete all as specified and directed. |
| 13 | Labour and T&P to attend electric complaints by skilled electrician of non functional control panel, starter, motor, MCCB, identifying & rectify the electric fault, tightening the electric loose connections, cable connections to make the plant functional complete all as specified and directed. |
| 14 | M&L for dewatering of complete balancing tank, removing all the dust particle, sand etc, cleaning complete inner portion of the tank including minor repair and painting of complete inner portion with water proof paint complete all as specified and directed. |
| 15 | S&F in replacement of dosing pump capacity 0-12 Amp suitable for chlorine dozer complete all as specified and directed. |
| 16 | S&F in replacement of CI diaphragm valve 50mm suitable for alum/soda dozer complete all as specified and directed. |
| 17 | S&F in repair of suction sweeper stainless steel body with nylon brushes of existing size and as per sample 3 feet long complete all as specified and directed. |
| 18 | Dismantling of compressor with air blower capacity 5HP electric motor from swimming pool transporting to civil workshop for repairing, dismantling of blower & motor re-assembling after complete repairing and carrying back to swimming pool & connecting with existing system and testing on load complete all as specified and directed.(Note: rewinding if required shall be measured and paid separately) |
| 19 | M&L for rewinding of air blower motor of capacity 5HP, three phase 415 volts, 50Hz AC with super enameled copper winding wire of existing size and gauge including insulating material, heating drying, assembling and testing complete all as specified and directed. |
| 20 | M&L for repairing of air blower of capacity 5HP, including replacement of ball bearing both DE & NDE sides, lubricating oil, assembling and testing on load complete all as specified and directed. |
| 21 | S&F in replacement of cable flat type with copper conductor of size 16 Sqmm 3 core complete all as specified and directed. |
| 22 | Dismantling of treated water mono block pump with 5.0 HP electric motor from swimming pool transporting to civil workshop for repairing, dismantling of motor re-assembling after complete repairing and carrying back to swimming pool & connecting with existing system and testing on load complete all as specified and directed. (Note: rewinding if required shall be measured and paid separately) |
| 23 | M&L for rewinding of treated water mono block pump motor of capacity 5.0 HP, three phase 415 volts, 50Hz AC with super enameled copper winding wire of existing size and gauge including insulating material, heating drying, assembling and testing complete all as specified and directed. |
| 24 | M&L for repairing of treated water mono block pump of capacity 5.0 HP, including replacement of bronze impeller, ball bearing, greasing assembling and testing complete all as specified and directed. |
| 25 | Dismantling of treated water mono block pump with 10.0 HP electric motor from swimming pool transporting to civil workshop for repairing, dismantling of motor re-assembling after complete repairing and carrying back to swimming pool & connecting with existing system and testing on load complete all as specified and directed. (Note: rewinding if required shall be measured and paid separately) |
| 26 | M&L for rewinding of treated water mono block pump motor of capacity 10.0 HP, three phase 415 volts, 50Hz AC with super enameled copper winding wire of existing size and gauge including insulating material, heating drying, assembling and testing complete all as specified and directed. |
| 27 | M&L for repairing of treated water mono block pump of capacity 10.0 HP, including replacement of bronze impeller, ball bearing, greasing assembling and testing complete all as specified and directed. |
| 28 | S&F in repair sluice valve 100 mm dia bore cast iron both end flanged with CI wheel high tensile brass spindle including fixing arrangement class PN-1.0 suitable for 100 mm bore MS pipe with all fittings such as rubber gasket sheet, washer, nut & bolt etc; complete all as specified and directed. |
| 29 | S&F in repair sluice valve 150 mm dia bore cast iron both end flanged with CI wheel high tensile brass spindle including fixing arrangement class PN-1.0 suitable for 150 mm bore MS pipe with all fittings such as rubber gasket sheet, washer, nut & bolt etc; complete all as specified and directed. |
| 30 | Taking down security light fittings / under water/ light fittings of any description omplete all as specified and directed. |
| 31 | S&F building security light of 30 Watt New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with high power LEDs as light source and electronic driver including all fixing arrangements complete all as specified and directed. |
| 32 | S&F in repair contactor ML-1.5 three phase 415 volt 50 HZ AC complete with 1 NO +1NC complete all as specified and as directed. |
| 33 | S&F in repair over load protection three phase 415 volt 50 HZ AC of rating 0-20 Amps complete all as specified and directed. |
| 34 | S&F in repair single phase preventor 415 volts 50 HZ complete with electronic circuit complete all as specified and directed. |
| 35 | S&F in repair for contactor ML-2 three phase 415 volts 50 HZ AC complete with 1NO +1NC complete all as sepcified and as directed. |
| 36 | S&F in repair MCCB 3 Pole 63 Amps, 415 volts, 25 KA rupturing capacity with adjustable thermal & magnatic setting complete all as specified and directed. |
| 37 | S&F in replacement of LED 200 watt energy saving environmental friendly, long life, exclusive innovative die-cast aluminium IP 66 flood light, suitable for highlighting architectural facaade and general purpose lighting with all connected accessories including bolts, nuts, brackets, suitable size of pipes for mounting of Light complete all as specified and directed. |
| 38 | S&F in repair star delta timer suitable size for automatic starter complete all as specified and directed Please Enable Macros to View BoQ information |