| 1 | Taking up and set aside the drain cover slabs and refixing the same with cement mortar 1:6, after cleaning the drain complete all as specified and as directed. Note : Cleaning of drains shall be measured and paid separatel. |
| 2 | Cleaning of open/Closed/storm water drain and removing all debris from the drain off the premises complete all as specified and as directed. |
| 3 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for like MH cover, drain pipe bed, hard standing etc complete all as specified and as directed. |
| 4 | M&L for Plain Cement Concrete in 1:4:8 mix type D2 using 40 mm graded stone aggregate as in foundation etc complete all as specified and directed. |
| 5 | M&L for PCC 1:2:4 mix, type B1 using 20mm graded stone aggregate as in surface channels and drains complete all as specified and as directed. |
| 6 | M&L for PCC 1:2:4, type B1 using 20mm graded aggregate as in bed block coping , or similar work and setting in cement mortar 1:6 complete with joint to match all as specified and as directed inclduing necessary form work , complete all as specified and as directed. |
| 7 | Demolition of Brick work or stone/ boulders masonary, built in cement mortar or cement lime mortar including all quoions, arches, pillars etc, but excluding ashlar facings dressed stone work and precast concrete articles complete all as specified and as directed. |
| 8 | M&L for brick work with Fly aash bricks straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and as directed. |
| 9 | M&L for rendering 15mm thick in cement mortar (1:4) on external surfaces of any face of brick wall or concrete surfaces, finished fair and even complete all as specified and as directed. |
| 10 | Demolition of cement concrete (reinforced) of any descritpion and in any position not otherwise specifically provided all as specified and as directed and depositing of the debris out of the premises complete all as specified and as directed. |
| 11 | Material and labour for providing precast cement concrete, 1:2:4, type B1, using 20mm graded stone aggregate as in landings, bed plates, pintle blocks, anchorage blocks, cover slabs(for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:6 including necessary form work complete all as specified and as directed.Note: Reinforcement bars shall be measured and paid separately. |
| 12 | Material and labour for Mild steel TMT bars in reinforcement, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-500D all as specified and as directed. |
| 13 | Material and labour for Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-500D all as specified and as directed. |
| 14 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 15 | Dismantling of Barbed wire in fencing of any description complete all as specified and as directed. |
| 16 | Dismantling concertina coil each of expended/stretched length up to 8.00 meter of any discription or in any position complete all as specified and as directed. |
| 17 | Supply, fabricate and fix Mild steel Angle Iron as in posts and struts in fencing incl cutting tops shape as directed welding, drilled notching for wire etc incl all necessary drilling etc. And similar work incl embedding in concrete conforming to Fe-410-0 or Fe-310-0 complete all as specified and as directed. Note : The unit rate quoted shall be deemed to include the cost for locking holes after fixing of barbed wire and welding to bent portion as directed. |
| 18 | Supply and fix galvanized, 2 strand, steel bar bed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossing with and provision of galvanized mild steel wire, staples or steel pins etc complete all as specified and directed.Note : Each line wire to be measured. |
| 19 | Supply and fix 600/610mm dia razor plade galvanised punched type concertina coil (50 turns per coil), weight of coil 8.75 Kg ±5%, Strechable to cover a distance of 5 to 6 RM with Central core wire made of high tensile galvanised spring core wire (HTGS) made up of 2.6 mm dia as per IS: 4454, Part-1, Grade-II having minimum galvanizing of 230 – 250 gms per sqm, with a tape of razor sharp barbs strip of 0.5 mm thick and 19 mm width conforming to IS: 513 DD, barbs punched along the length at regular interval of 120 barbs per running meter, crimped with 4 to 5 Nos. of clips per each spire made up of Stainless Steel (SS-304) including fixing of concertina coil in position and secured both sides of 'Y' shape angle iron post with 2.642mm GI binding wire, u-nails / split pin, etc., complete all as specified and as directed. |
| 20 | M&L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and as directed. |
| 21 | M&L for 100mm thick, Plain Cement Concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base complete all as specified and as directed. |
| 22 | Material and labour for chequered cement concrete tiles 20cmx20cmx25mm thick, with grey cement and pigment set, jointed and pointed in ne cement sluury in floor over and including 15mm thick screed bed or bedding layer in CM 1:6 for laying floor finishes, complete all as specified and as directed. |
| 23 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in Soft and loose soil complete all as specified and as directed. |
| 24 | Removing excavated spoil to a distance exceeding 250 Mtrs but not exceedng 500m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed. |
| 25 | Material and labour for Hardcore of gauge not exc. 63mm using Broken stone or boulders, deposited spread and levelled in layers not exceeding 15cm thick, watered and well rammed to a true surface all as specified and as directed. |
| 26 | Material and labour for 50mm thick sand cushoining laid over sub base for fixing interlocking tiles complete all as specified and as directed. |
| 27 | Material and labour for laying of machine pressed precast concrete interlocking paver block, 60 mm thickness, M-35 grade with grey cement and pigments of any shape and size confirming to IS 15658-2006 complete all as specified and as directed. |
| 28 | Material and labour for cleaning of RCC service water tank capacity 25000L to 30000L of any pattern or make by draining out the brackish / muddy water and applying bleaching powder in the bottom, side wall by and scrubbing and removing scale dirt and fungus with steel wire brush cleaning two time with fresh water and one coat of white wash, re-fix the PCC cover in proper and writing the capacity / date of cleaining with black and black and white paint complete all as specified and as directed. |
| 29 | Supply and fix 8mm thickToughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required for Toughened flat glass 08mm thick (Glass rough grinding flat tempered coating on #2-TPRS tuff ISI CE black colour logo) TPRS tuff glass for face of external vertical wall of high rise buildings complete all as specified and directed. |
| 30 | M&L for Stainless steel friction stay Arms Frame (for fitting 0.585mtr x 0.710mtr each glass size), McCOY Magnum series friction stay (SS-308 grade), Size-14\\" Marketed by :- Mc COY Cilicones Ltd. (Fenestration Division) or equivalent for casing/ framing to toughened flat glass 08mm thick for external face vertical wall of high rise buildings complete all as specified. |
| 31 | M&L for Ebco window/ door handle with push latch block finish and size 71x53mm, WDHI-PL for block/ catch to glass window fitted with existing stay Arms frame along with wall fitted existing Aluminium frame for external face vertical glass structure wall of high rise buildings complete all as specified. |
| 32 | Taking down cement plaster on brick or stone walls etc, including raking out joints, hacking for key scrubing down with water etc complete all as specified and as directed. |
| 33 | Material and labour for rendering in Cement Mortar 20mm thick in two coats, i.e, in Cement Mortar 1:4, 10mm thick mixed with water proofing compound as per manufacturers' instructions over in Cement Mortar 1:6, 10mm thick on fair faces of brick/concrete surfaces, finished even and fair externally all as specified and as directed.Note: WPC will be measured and paid separately. |
| 34 | Supply only Liquid water proofing compound. |
| 35 | M&L for Preparation of new wall surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. |
| 36 | M&L for Preparation of newly plastered surfaces and applying two coats of cement base paint over a coat of primer complete all as specified and as directed. |
| 37 | Preparation of old surface of walls and applying one coat of cement base paint complete all as specifed and as directed . |
| 38 | Preparation of old surface of walls chajja, facia and applying one coat of Exterior emulsion paint (wheather coat) complete all as specifed and as directed. |
| 39 | Preparation of old painted surfaces and applying one coat of synthetic enamel paint on steel surfaces of any description not other wise described over 10 cm width or grith etc complete all as specifed and as directed. |
| 40 | M&L for complete removel of existing treatment or Scrapping down old treatment of any description and applying Two or more coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company Depot Tinted ) with silicon additives @1.43 liter/ 10 sqm over and including priming coat of exterior primer aplied @ 0.9liter/10sqm over new surface complete all as specified and as directed. |
| 41 | Demolition of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing to store and rubbish off the premises complete all as specified and as directed. |
| 42 | Demolition of unreinforced cement concrete, PCC in ground floor and pavings n.exc. 15 cm thick (below or above GL) complete all as specified and as directed. |
| 43 | Material and labour for 25mm thick cement concrete in 1:2:4 mix, Type-B1using 20 mm graded stone aggregate as in sub base flooring complete all as specifed and as directed. |
| 44 | Material and labour for Virified ceramic tiles of grade B-I(a), 9-10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, laid in floors of pattern as approved over and including 15mm thick screed bed in Cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed. |
| 45 | Material and labour for Virified ceramic tiles of grade B-I(a), 9-10 mm thick (square/ rectangular) polished, of size matching to floor tile as approved, fixed in vertical surfaces such as in skirting/dado set and jointed in neat cement slurry and pointed in white or coloured cement to match floor tile over a backing coat in Cement Mortar 1:4, 10mm thick on fair faces of brick or concrete surfaces all as specified and as directed. |
| 46 | Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) of size exceeding 1.50 Sqm but n.exc 4 Sqm each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts complete all as specified complete all as specified and directed. |
| 47 | Supply and Fix Solid PVC door frame of size 50mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with mild steel square tube complete all as per specification & drawing shown in MES schedule part II complete all as specified and as directed. |
| 48 | Supply and Fix Factory made PVC Solid panel door shutters 30mm thick (style) solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin) consisting of frame made out of mild steel tubes for top and bottom rails, mild steel frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail Paneling of plain colour PVC sheet to be fitted in the mild steel frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement supply and fixing in the frame at site as per specification and drawings shown in MES schedule part II complete all as specified and as directed. |
| 49 | Dismantling wall and ceiling boards (fibre, pulb insulation etc) or insulation boards slabs/ blankets any thickness including cover fillets complete all as specified and as directed. |
| 50 | M&L for suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system) of grid size 600mm x 600mm with main runner 38mm x 24mm and wall angle 24mm x 24mm using 8mm thick high Pressure Non Asbestos Fiber Cement decorative Board 8mm thick (E-Board Classic) in a grid of aluminium duly suspended with 4mm dia GI bar hanger fixed with steel dash fasteners or iron purline from the roof eith adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinkler, smoke detectors etc. The main runners to be secured to structural soffits by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be interlocked between main runners @ 610mm c/c, as to form 600mm x 600mm grid all as specified and directed. Make : Gytech (Saint Gobin - Design No 154 Industries Ltd or equivalent as per IS 14862 complete all as specified and directed. |
| 51 | Dismantling existing old sewage/ drain pipe PVC/ CI 100mm dia or more any discription from wall and drain connected from existing line including clamps complete all as specified and directed. |
| 52 | Supply and fix 110 mm bore UPVC (SWR) pipe, single socketed in any length with rubber ring joints, fixed to walls complete all as specified and as directed. Please Enable Macros to View BoQ information |