| 1 | NOTE (Applicable for all parts/items):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. |
| 2 | SCHEDULE \\"A\\" Part - I (BUILDING / STRUCTURES WORK-EPC MODE ) Details of pre priced schedule is given in tender documents. |
| 3 | SCHEDULE \\"A\\" PART-II (SITE CLEARANCE, LAND DEVELOPMENT AND EARTH WORK ) Details of prepriced Schedule is given in tender documents |
| 4 | SCHEDULE \\"A\\" PART-III (DEMOLITION OF B/R & E/M) Details of prepriced Schedule is given in tender documents |
| 5 | SCHEDULE \\"A\\" PART-IV (COVER SHED ) Details of prepriced Schedule is given in tender documentsROADS/PATH/CULVERT/HARD STANDINGINTERNAL WATER SUPPLY |
| 6 | SCHEDULE \\"A\\" PART-V (ROADS/PATH/CULVERT/HARD STANDING ) Details of prepriced Schedule is given in tender documents |
| 7 | SCHEDULE \\"A\\" PART-VI (INTERNAL WATER SUPPLY ) Details of prepriced Schedule is given in tender documents |
| 8 | SCHEDULE \\"A\\" PART-VII (INTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents |
| 9 | SCHEDULE \\"A\\" PART-VIII (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents |
| 10 | SCHEDULE \\"A\\" PART-IX (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents |
| 11 | SCHEDULE \\"A\\" PART-X (EXTERNAL WATER SUPPLY ) Details of prepriced Schedule is given in tender documents |
| 12 | SCHEDULE \\"A\\" PART-XI (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents |
| 13 | SCHEDULE \\"A\\" PART -XII (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col.' 5 ' signifies this fact only. |
| 14 | M&L for 10mm thick Non skid ceramic paver tiles area of each tile exceeding 0.08 Sqm but not exceeding 0.18 Sqm as in floor set, jointed &pointed with white cement and pigment over and including 15mm thick screed bedding layer in cement mortar (1:4) complete all as specified and as directed. |
| 15 | S & F 15mm bore push cock fancy type for urinal and connected with pipe complete all as specified and as directed. |
| 16 | S & F Two way Bib Taps with wall flange, quarter turn (low flow), cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as specified and as directed. |
| 17 | M & L for Soakage Well of size 3.6m dia and 3.00m effective depth including excavation in any type of soil, Foundation in PCC 1:3:6, type C2 with Honeycombed Masonry Walls with top ring in M25 Grade Design Mix Concrete including Intercepting Chamber and Screen Chamber made of Brick Masonry in Cement Mortar 1:6, RCC Cover Slab in M25 Grade Design Mix Concrete / SFRC Cover interconnecting pipes of RCC/DWC complete filled with brick bats with all ancillaries, fittings, fixtures complete all as specified and as shown on drawings and as directed. |
| 18 | M & L for RCC Hume Pipe Septic Tank of 50 Users Capacity designed to carry Sewage and Sullage Water including excavation in any type of Soil, PCC 1:4:8, Type D2, below Foundation, RCC M-30 Design Mix using 20mm graded stone aggregate Walls, Base Floor, Baffle Walls and Roof Slab including Beams etc. with Vent Shaft, Manhole openings with Cover, necessary connections etc., complete with effective depth of 1.50 meter and overall depth of 3.00 meter complete all as specified and as directed. |
| 19 | Taking down unserviceable LED light fitting of any type complete all as specified and as directed. |
| 20 | Taking down unserviceable MCB DBs of any type complete all as specified and as directed. |
| 21 | Taking down unserviceable service cable of any type complete all as specified and as directed. |
| 22 | Supplying, Installing, Commissioning and Testing of CPRI Prototype tested, Factory made, Free Standing Floor Mounted, Dust and Vermin proof LT Panel board, Compartmentalised, Outdoor type, fabricated with 3.15mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces. The panel shall consist of aluminium bus bars of high conductivity of suitable size and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain insulator supports, suitable double Compression Copper Cable Glands and panel shall be provided with separate compartments for each switch, with gland plates, lifting hooks, shutter type ventilating louver at both top & bottom duly internally secured with wire mesh, with suitable internal wiring with copper cable of suitable size, including instrumentation such as Ampere Meter, Volt Meter, Phase Indicating LED Lamps [RYB], Selector Switches etc with double stud hinged door, front openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts Grade, 3 Phase, 415 Volts, 4 Wire, 50 Hz, AC Supply and to withstand short circuit fault level of not less than 100KA and degree of protection shall be IP 65. (Cont...) |
| 23 | The panel shall be fixed with angle iron frame made of angles of size 40X 40 X 5mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level complete including connecting up with existing incoming and outgoing cables etc. and comprising the following(Main Panel No. 1) :[a] MCCB, 250 Amps, FP, 36 KA, 415 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 1 No. [Incoming][b] MCCB, 160 Amps, FP, 36 KA, 415 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 2 No. [Outgoing][c] MCCB, 100 Amps, FP, 16 KA, 415 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 01 No. [Outgoing][d] On load change over switch 250 Amps - 01 No [Outgoing].[e] Aluminium bus bar 600 Amps of suitable size and length duly insulated with colour code-04 Nos.[f] Digital type Ammeter of Range 0 – 500 Amps with CTs & Selector Switch – 4 Nos [1 Set].[g] Digital type Voltmeter of Range 0 – 500 V with Selector Switch – 1 Nos.[h] Colour Coded LED Phase Indicating Lamps for each Phase – 1 Set. |
| 24 | Supplying, installing, testing and commissioning of 5 Star rated Hi-Wall Split Units Indoor / Outdoor with Cordless Remote Control Unit and with in-built advanced Air Ioniser and Plasma Filters for better indoor air quality with latest Inverter technology, having Eco friendly Refrigerant Gas, Copper Condenser Coil, EER 3.2 of Capacity 1.5 TR, Summer Cool, Dual Rotor Inverter Compressor, Automatic 4D Swing Copper Condenser, BLDC Motor, necessary copper pipe connections including cutting, bending, brazing, insulation on pipe etc, PVC Drain Pipe, electric connection between indoor and outdoor unit with suitable size PVC insulated, multi-stranded copper cable complete all as specified and as directed. Note: The rate quoted by the contractor is deemed to include for Powder Coated Mild Steel Fixing Brackets for Outdoor and Indoor Units at any height and Copper tube of suitable size and length and Drain Pipe made of High Density Polyethylene Pipes [HDPE] of pressure rating 6 KGf / Sq.cm of 20mm dia upto 5m length. |
| 25 | Supplying, installing, testing and commissioning of 5 Star rated Hi-Wall Split Units Indoor / Outdoor with Cordless Remote Control Unit and with in-built advanced Air Ioniser and Plasma Filters for better indoor air quality with latest Inverter technology, having Eco friendly Refrigerant Gas, Copper Condenser Coil, EER 3.2 of Capacity 2.0 TR, Summer Cool, Dual Rotor Inverter Compressor, Automatic 4D Swing Copper Condenser, BLDC Motor, necessary copper pipe connections including cutting, bending, brazing, insulation on pipe etc, PVC Drain Pipe, electric connection between indoor and outdoor unit with suitable size PVC insulated, multi-stranded copper cable complete all as specified and as directed. Note: The rate quoted by the contractor is deemed to include for Powder Coated Mild Steel Fixing Brackets for Outdoor and Indoor Units at any height and Copper tube of suitable size and length and Drain Pipe made of High Density Polyethylene Pipes [HDPE] of pressure rating 6 KGf / Sq.cm of 20mm dia upto 5m length. |
| 26 | S & F Electronic wall mounted time delay Voltage stabilizer of 3 KVA Capacity, Automatic Operation, for input variation of 170 Volts to 250 Volts with stabilised voltage of 230 Volts with accuracy of ± 2.5% complete all as specified. |
| 27 | Supply and fixing Decorative LED wall mounting, Champagne gold finish fixture with plastic body of 9 W, Base type B-22 LED lamp complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 28 | S & F Indicator Lamps red colour, 5/6 Amps complete all as specified and as directed. |
| 29 | S & F Wall Mounted Air Circulator Fan, 400mm Sweep, Metal Body, Heavy duty with double ball bearing, low noise, Copper wound, 1400 RPM, Air Delivery not less than 270 Cum/min, wattage consumption not more than 190 watts, 230 Volts, AC, 50 Hz, Conforming to IS, Wall Mounting Type complete with wall bracket and mounting accessories kit complete all as specified and as directed. |
| 30 | Material & Labour for GI bracket of 40 mm bore, light grade, 1.20 metre long, 120-130 degree with MS clamp made out of 25x3 mm flat iron, bent to shape and fixed on wall with 02 Nos metal fashener, 10 mm size including drilling hole for building security light complete all as specified and as directed. Please Enable Macros to View BoQ information |