| 1 | Taking down cement plaster on brick walls, raking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.Note: Rate also includes for necessary scaffolding/Jhoola work to carry out work upto a height G+7 floor and removal of debris outside MoD land all as spd. |
| 2 | M&L rendering 15 mm thick in CM (1:6) on brick walls or concrete surface, surface finished even and smooth without using extra cement complete all as specified and directed. Note:- (i) Rate also includes necessary scaffolding/Jhoola works to carry out work upto a height G+7 floor |
| 3 | M&L rendering 15 mm thick in CM (1:4) on other than fair face of brick walls or concrete surface, surface finished even and smooth without using extra cement complete all as specified and directed. Note:- (i) Rate also includes necessary scaffolding/Jhoola works to carry out work upto a height G+7 floor |
| 4 | M&L for 5mm thick cement plaster on brick/concrete surface in CM 1:3 finished even and smooth surface without using extra cement complete all as specified.Note :- Rate also includes necessary scaffolding/Jhoola works to carry out work upto a height G+7 floor. |
| 5 | M&L for applying two coat of oil bound distemper on walls including preparation of new/un decorated surfaces including filling minor holes with wall care putty and including brooming down or steel wire brushing, scrubbing down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots complete all as specified and as directed |
| 6 | Description all as per item here-in-before but on ceiling |
| 7 | M&L for applying two coats of 100% Premium acrylic emulsion paint with roller/spray having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including water based priming coat of exterior primer applied @ 0.90 litre/ 10sqm over surface complete all as specified and directed. Make : Asian paints (apex ultima)/Berger (weather coat all ground)/Nerolac (excel total)Note:- (i) The application will be done by the specialist agency. MOU will be submitted by the contractor with the OEM.(ii) Rate also includes necessary scaffolding/Jhoola works to carry out work upto a height G+7 floor. |
| 8 | M&L for applying one coat of synthetic enamel paint over old painted steel surfaces of any descripition over 10cm width or girth including preparation of old surfaces complete all as spd and as directed |
| 9 | Demolition of brick work or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, aches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles all as spd and directed |
| 10 | Brickwork with fly ash modular bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 all as specified and directed. |
| 11 | All as per item 10.00 above but except bricks |
| 12 | M&L rendering 15 mm thick in CM (1:4) on brick walls or concrete surface, surface finished even and fair complete all as specified and directed. |
| 13 | M&L for broken glass coping on top of wall with CM 1:3 including taking and removing old unusable glasses complete all as specified and directed. |
| 14 | Dismantling wrought iron or mild steel work of any description not otherwise provided for. |
| 15 | S&F Rolled mild steel Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lenghts i.e. within 20mm of the length indicated) GDE Fe 410-0 W (Gde E-250) quality A complete all as specified and directed. |
| 16 | S&F Mild steel bands, straps, supports or stay, for rain water, ventilating pipes including bolts if reqd, hooks (stay) heavy for large gates hook and pintle large hasps and staple, chains hand made sliding bolts clamps, hold fasts wall ties etc etc hooks for hanging fans plain angle cleats for securing purlins to wood truss or rafter, knee piece inserts, two way and three way straps, plate washer and similar small articles confirming to Fe-410-0 or Fe-310-0 all as spd and directed |
| 17 | S&F (Ornamental gate) Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-1657 including portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc.ornamental and intricate design complete all as specified and directed. |
| 18 | Supply & fixed in repairs Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc complete all as specified and directed. Note : Each line wire to be measured. |
| 19 | M & L in repairs concertina coil 610 mm dia, 125 to 127 clips per coil, 50 circles of wire in each coil (coil coverage of 6-8RM and weight approx 8.5 Kg per coil), GI wire, GI clips, GI pins and fixed on top of compound wall with angle iron bracket all as specified.Note: Angle iron bracket will be measured & paid separately. |
| 20 | M&L preparation of new steel & iron surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over and including one coat of primer all as spd and directed. |
| 21 | Dismantling Asbestos corrugated & Semicorrugated etc sheet in roof covering of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as directed at site. |
| 22 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified. |
| 23 | Taking out for repairing of rolling shutter push type with necessary repair work of defective parts i.e, re posting of laths, riveting to old defective rivets, tightning nuts and bolts, replacement of spring, greasing to movable parts and at guide channel, greasing the sides of the rolling shutter and re-fixing rolling shutter for smooth functioning size of rolling shutter not exceeding 10 Sqm each complete all as specified and directed.Note : Rate includes the replacement of broken spring |
| 24 | S&F in repair 1.25mm lath thickness Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified and directed. |
| 25 | S&F in repair Ball bearing for rolling shutters complete all as specified and directed. |
| 26 | S&F in repair Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed. |
| 27 | Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed. |
| 28 | M&L for rubber moulded prepolished coloured precast concrete interlocking paver block 60mm thick of any shape and size with white cement and pigment confirming to IS 15658-2006 M-35 Grade, complete all as specified and directed. |
| 29 | M&L Sand filling/stone dust under floors or in foundations including watering and consolidation spreading and levelling in layers n exc. 25 cm thick complete all as specified and directed. |
| 30 | Demolition of cement concrete in ground floors and pavings etc not exc 15 cm thick above or below ground level including removal of debris out side MoD land all as directed. |
| 31 | M/L Cement concrete type C2 1:3:6 (40mm graded aggregate) as in foundations, filling and mass concrete/Subbase complete all as specified and directed. |
| 32 | M&L 75mm thick PCC type C-2, (1:3:6) using 40mm graded stone aggregate as in plinth protection,subbase etc complete all as specified and directed. |
| 33 | M&L prepolished coloured chequred cement concrete tiles 300X300X25 mm size set in screed bed 20 mm thick in cement mortar 1:4 all as specefied and directed by Engr -In -Charge. |
| 34 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for including removal of debris outside MoD land all as spd. |
| 35 | S&F Factory made precast heavy duty drain/ manhole covers including MS frame and including reinforcement as per IS 12592 : 2002 with specified thickness complete all as specified and directed by Engineer-in-Charge of make approved by GE (I). |
| 36 | Material and labour for pre-cast reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cover slabs,manhole cover and similar work including necessary form work complete all as specified and directed. |
| 37 | S & F Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete as directed and specified. |
| 38 | Supply and fix mild steel round bars 10mm dia FE 410W Gde E-250 quality A or Fe 290 gde E-165 cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips for man hole cover handle complete all as specified and directed. |
| 39 | S&F in repairs Welded steel wire fabric supplied and fixed complete to wood or steel members weight n.exc 4kg per sqm complete all as specified and directed. Note : Rate also includes for necessaryscaffolding /Jhoola work to carry out work upto a height G+7 floor. |
| 40 | M&L Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings .complete all as specified (Paymentfor providing grooves shall be made separately).including taking down old grit plaster.Rate also includes for necessary scaffolding/Jhoola work to carry out work upto a height G+7 floor and removal of debris outside MoD land all as spd. |
| 41 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m in all kind of soil all as spd and directed. |
| 42 | Returning, filling in hard/dence loose soil including spreading, leveling, watering and well ramming in layers n.exc. 25 cm complete all as specified and as directed by Engineer-in-Charge. |
| 43 | Removing excavated material/Malba to a distance exceeding 1.5 KM and not exceeding 20 KM depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed. |
| 44 | M & L PCC(1:4:8) type D-2 using 40mm graded stone aggregate in foundation mass concrete and filling comlete all as specified and directed. |
| 45 | M & L PCC(1:3:6) type C-2 using 40mm graded stone aggregate in foundation mass concrete and filling comlete all as specified and directed. |
| 46 | M & L PCC(1:2:4) type B-1 using 20mm graded stone aggregate as in coping complete all as specified and directed. |
| 47 | S&F Reinforced concrete pipes 200mm bore class NP – 2, laid and jointed complete with collars, all as specified and directed by Engineer - in - Charge. |
| 48 | S&F Reinforced concrete pipes 300mm bore class NP – 2, laid and jointed complete with collars, all as specified and directed by Engineer - in - Charge. |
| 49 | M&L Salt glazed stoneware drain pipe Grade 'A' 150 mm bore laid in trenches and jointed including taking down existing pipe complete all as specified and directed. |
| 50 | M&L Salt glazed stoneware drain pipe Grade 'A' 200 mm bore laid in trenches and jointed including taking down existing pipe complete all as specified and directed. |
| 51 | M&L cement concrete bed (1:4:8 type D2) to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested 150mm dia complete all as specified and directed. |
| 52 | M&L cement concrete bed (1:4:8 type D2) to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested 200mm dia complete all as specified and directed. |
| 53 | M&L cement concrete bed (1:4:8 type D2) to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested 300mm dia complete all as specified and directed. |
| 54 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends, complete all as specified and directed. |
| 55 | Cutting into existing manholes for connecting new drains/pipe, making good to pipe and rendering, cutting out existing benches for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150mm internal dia for pipe all as specified and directed |
| 56 | Dismantling wall/ceiling boarding, any description, fixed in any position with nails/screws/grid including taking down E/M fittings/fixtures on ceiling and refixing the same after completion of work to make it functional complete all as specified and directed. |
| 57 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking GI metal grid of hot dipped galvanized steel sections consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture having 8 to 10 mm thick square edge PVC Laminated Gypsum board Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge |
| 58 | M&L in repair for decorative wall panelling with PVC/WPC louvered/Fluted/Plain 2D/3D wall panels with plastic and silicate mixture as the core material with inand surface with PVC foil on the top with thickness of panel 10mm to 20mm, width of 150mm to 200mm and length of 2.74/3.05 (9' or 10') meters of POLYWOOD or equivalent brand Wt of PVC pannel is 4.5 kg/sqm and PVC percentage in wall panels is more than 40% including necessary L/H/U corner profile and fillets. WPC Wall panel are termite proof , water proof and usable on the damp walls, fixed to wall/ ceiling surface as per manufacturer instruction complete all as specified and directed by Engr-in-charge. |
| 59 | Taking down chowkhat or frames with shutters (without taking off shutters from the frame)n.exc 1.5sqm and making good to distrubed surface without any extra cost complete all as specified and directed. |
| 60 | Taking down chowkhat or frames with shutters (without taking off shutters from the frame)exc 1.5sqm but n.exc 4 Sqm and making good to distrubed surface without any extra cost complete all as specified and directed. |
| 61 | Taking down shutters exc 1.00 sqm but n.exc 2.00 Sqm each |
| 62 | S&F 35mm thick 2nd class hard wood glazed and skelton door shutter open rebated and prepare to receive glass, gauge etc (without sash bars) edges of framing palin, chamfered rounded fitted with cut and mitred beads for securing glass etc sizes of member as spd in SSR Part I sec 8 clause 8.20 (a) all as spd and directed |
| 63 | S&F stainless steel wire mesh of size 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 64 | S&F 35mm thick flush shutter solid core construction with block board core and ply wood face panels commercial type on both sides all as spd and directed |
| 65 | M&L for applying two coat of synthetic enamel paint over new wooden surfaces of any descripition over 10cm width or girth including preparation of surfaces complete all as spd and as directed by Engineer-in-Charge |
| 66 | S & F factory made solid pannel PVC door shutter 30mm the style consisting of frame made out of MS tube, for top & bottom rail, MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheet for top rail, bottom rail & lock rail on either side & as gap insert for top rail and bottom rail. panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement as per spacification and drawing. |
| 67 | S&F Steel window 1.25mm thick box type ERW hollow P section of each frame size 60mmx25mm double rebated comprises of glazed & guaged skelton shutter ERW section 50mmx20mm&1mm thick with one openable leaf consisting of two number sash bars of T-section 20mmx3mm complete welded to frame with one vertical mullion of ERW box type T-section of size 60mmx25mm and 1.25mm thick with following fittings welded to the frame shutter complete all as specified and directed :- (i) Holdfast 150mm long mild steel flat iron 12x3mm made to shape-04 Nos per window. (ii) Handle of Z section 20mmx25mm,100mm long-01No per leaf (iii) MS Tower bolt 150mm long 2Nos per leaf (iv) Z section 20mmx25mm,100mm long stopper-1No per leaf (v) Cleat 55 mm long of solid square 15x20x63mm square-01 No per leaf (vi) Pintol hinges 12x75mm -2 Noseach leaf (vii) 12mm square Guard bar @ 10cm c/c (viii) 25x3mm flat iron joint of both frame wiremesh&glazed weldedinner side and outer side of frame. (ix) Two coat of synthetic enamel paint over one coat of primer. (x) Cutting holes and making good dismantled portion in PCC 1:2:4 type B-1 cement plaster 1:4 as require and make finish good to the existing surface complete all as specified and directed. |
| 68 | S&F stainless steel wire mesh of size 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 69 | S&F 4 mm thick sheet glass in squares/rectangle not exc 0.50 sqm in each pane fixed with wooden beads or putty (in metal/wooden frames etc) upto a height of G+7 including necessary steel/wooden scaffolding etc complete all as specified and directed. |
| 70 | S&F in repair manually opening and closing roller type blinds of approved make with characteristic composition of fabric of polyster and nylone semi transparent type complete all as specified and directed. |
| 71 | S&F in repair vertical venetian blind consisting of aluminium head rail, vanes/louvers 4” wide of approved tint and traverse cord complete fixed in position complete all as specified and directed. |
| 72 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises all as spd and directed |
| 73 | M&L for light shade Vitrified Ceramic tiles 10 mm thick (square/ rectangular)polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 complete all as specified and as directed by Engr-in-Charge. |
| 74 | M&L for light shade Vitrified Ceramic tiles 10 mm thick (square/ rectangular)polished, area of each tiles not exceeding 0.06 sqm,vertical surfaces as in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 10mm thick cement mortar in CM 1:4 complete all as specified and as directed. |
| 75 | M&L non skid ceramic coloured tiles 8 to 9 mm thick (square/ rectangular) polished, area of each tiles exc.0.18sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry, over and including 15 mm thick in CM 1:6 and pointed in white or coloured cement to match complete all as specified and directed. |
| 76 | M&L non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) polished, area of each tiles exc.0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry, over and including 15 mm thick in CM 1:6 and pointed in white or coloured cement to match complete all as specified and directed. |
| 77 | M&L for glazed ceramic tiles in vertical surface 600 X 300 X 7 to 8mm thick for wall cladding, set and jointed in neat cement slurry over and including 10 mm thick rendering in CM 1:4 and pointed in white or colour cement to match complete all as spd. |
| 78 | M&L for Glazed ceramic tiles in vertical surface 450 X 300 X 7mm thick set and jointed in neat cement slurry over and including 10 mm thick rendering in CM 1:4 and pointed in white or colour cement to match complete all as specified and directed. |
| 79 | M & L in repairs for Providing precast cement concrete louvers and jallies, 25mm thick (measured solid), including all mouldings but excluding frame (precast frame shall be measured separately and paid for under item 04032) With B0 Type, 1:2:4 mix, (using 12.5 graded aggregate)set in cement mortar1;4 complete all as specified and directed. Please Enable Macros to View BoQ information |