Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking down chowkhats or frames with shutter (without taking off shutters from the frame) of size exc 1.5 sqm but not exc 4 sqm and making good to distrubed surface without any extra cost complete all as specified and directed. |
| 2 | Taking down chowkhat or frames with shutters (without taking off shutters from the frame) not exc 1.5sqm and making good to distrubed surface without any extra cost complete all as specified and directed. |
| 3 | M&L Cutting openings, through brick walls for door, window and other openings or enlarging existing openings, converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc. to store and rubbish not exc. 50m complete all as specified and directed |
| 4 | Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work making good with CM 1:6, complete all as specified and directed. |
| 5 | Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars, arches etc complete all as specified and directed. |
| 6 | M&L for brick work straight or curved on plan exc 6m mean radius in cement mortar (1:4) with Sub class ‘B’ brick including manhole raising, footpath, etc complete all as specified and as directed by Engineer-in-Charge. |
| 7 | M&L for UPVC casement door and window with sliding or side hung arrangement of size not exceeding 5.0 sqm having 3 track slider arrangement including 5 mm glass with gasket and silicon sealant and provision of sliding mosquito wire mesh complete dust proof including all necessary builder hardware complete as per engineer in charge |
| 8 | S&F anodised aluminium powder coating aluminium section weighing not less than 0.55Kg/m {minimum thickness of powder coating 50 micron)frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified |
| 9 | S&F anodised aluminium Powder coating door shutters aluminium section weighing not less than 0.55Kg/m {minimum thickness of powder coating 50 micron) including necessary joining cleats, glazing clips, ruber neoprene packing , hinges,anodised aluminium snap beading screws,all necessary builders hardware etc complete all as specified. |
| 10 | S&F anodised aluminium Powder coating window and ventilator shutters, side hung type without sash bars aluminium section weighing not less tha 0.55Kg/m including necessary joining cleats, glazing clips, ruber neoprene packing , anodised aluminium snap beading screws ,anodised aluminium fittings such as peg stays 150mm long (1no), hinges type B-21 100mm long(2 no.) suitable handle(1 no) including all necessary builders hardare complete all as specified. |
| 11 | S&F in repair aluminium anodised fully glazed partly panelled partitions and fixed glazing made out of anodized alum section 63.50x 38.10 x 1.60mm including necessary jointing cleats glazing clips, rubber packing anodised alum snap beading screws etc, frame work fixed to walls , floor and ceiling with rawl plug wherever required complete all as spd and as directed by Engineer-in-Charge (Sheet glass and particle board shall be measured and paid for separately) Note : area of each panel shall not be exc 01 sqm |
| 12 | S&F 12mm thick particle board exterior grade with decorative prelaminated both sides of approved shades fixed to aluminium shutters/ partitions complete all as specified and directed. |
| 13 | S&F 4.8mm thick sheet glass ordinary quality in Square/rectangle fixed with glazing pins and rubber beading etc in aluminium door/window/partitions etc complete all as specified and directed. |
| 14 | Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar, complete all as specified and directed. |
| 15 | M&L for machine cut kota stone slab flooring 20-22mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completed. Including 20mm thick screed bed or bedding lay in CM 1:6. complete all as specified and directed. |
| 16 | M&L 100 mm thick cement concrete type D-2,1:4:8 (40mm graded stone aggt) as in sub floors, filling and mass concrete etc complete all as specified. |
| 17 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge. |
| 18 | M&L glazed ceramic tiles (300x450/ 300x600) x7 to 8 mm thick coloured tiles in vertical surfaces, wall claddings, boundry wall dado etc set and jointed in neat cement slurry and pointed in white or colour cement to match as in dado over 10mm thick cement plaster in CM (1:4) complete all as specified and directed. |
| 19 | M&L vitrified ceramic tiles light shade 8 mm to 9 mm thick (square/rectangular) polished,area of each tiles exc 0.16 sqm but n.exc 0.36 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 20 | Taking down cement plaster/grit plaster any description on brick/concrete surfaces etc including raking out joints hacking for key, scrubing down with water etc complete all as specified and as directed. |
| 21 | M&L 15mm thick rendering in cement mortar 1:6 on fair faces of new or old brick works or concrete work finished even & smooth without using extra cement complete all as specified and as directed. |
| 22 | M&L 15mm thick rendering in cement mortar 1:4 on other than fair faces of new or old brick work or concrete work, finished even & smooth without using extra cement complete all as specified and as directed. |
| 23 | M&L preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper (white or tinted) over a coat of alkali resistant primer complete all as specified and directed. |
| 24 | M&L for preparation of newly plastered or unplastered wall surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. |
| 25 | M&L for Complete removal of existing treatment including preparation of plastered or unplastered old decorated surfaces of walls incl pillasters and cornices etc. incl washing, rubbing down and stopping the previously treated surfaces and applying two coat of oil emulsion distemper of approved shade/tint over and including one coat of 1 mm thick birla wall care putty to achieve smooth finish complete all as specified & directed. |
| 26 | M&L for Complete removal of existing treatment including preparation of plastered or unplastered old decorated surfaces of walls incl pillasters and cornices etc. incl washing, rubbing down and stopping the previously treated surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed.Note:- This item includes use of necessary scafffolding and safety net up to G+5 storey building. |
| 27 | M&L for PCC type B1 1:2:4 (using 20mm graded agg) in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelersm apexstone, bed plates, including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 28 | S&F MS Framed work with MS angle, channels, ISMB, gusset plates, rails, braces,Chequred plates,flat iron, Nut, bolts, rivets, connecting MS plates etc as in Fire exit stair case, barreled iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks, cover grills and similar work etc complete drilled for fixing of steel sheeting or other covering including welding work ,PCC work 1:1.5:3 in grouting etc to be prepared including MS fasteneres, hooks, hinges,necessary holdfasts etc and including all kind of ERW welding, induction butt welding, riveting work and fixing in building upto 12 mtr height complete all as spfd and directed by engr in charge. |
| 29 | M&L for preparation of newly steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. |
| 30 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking GI metal grid of hot dipped galvanized steel sections consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture having 8 to 10 mm thick square edge PVC Laminated Gypsum board Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge |
| 31 | Supplying and laying of CPVC pipes 25 mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including taking down of old pipes complete all as specified. |
| 32 | Supplying and laying of CPVC pipes 20mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including taking down of old pipes complete all as specified. |
| 33 | S&F CPVC Brass Elbow fitting suitable for CPVC pipes 25mm outer dia SDR 11 & Plain CPVC SDR 11 pipes complete all as specified. |
| 34 | S&F CPVC Brass Elbow fitting suitable for CPVC pipes 20mm outer dia SDR 11 & Plain CPVC SDR 11 pipes complete all as specified. |
| 35 | S&F CPVC Brass TEE fitting suitable for CPVC pipes 25mm outer dia SDR 11 & Plain CPVC SDR 11 pipes complete all as specified. |
| 36 | S&F CPVC Brass TEE fitting suitable for CPVC pipes 20mm outer dia SDR 11 & Plain CPVC SDR 11 pipes complete all as specified. |
| 37 | Earth work in surface excavation in all kind of soil not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m,including Clearing away all grass vegetation, saplings,shrubs, brushwood, undergrowth, roots, and trees not exceeding 30 cm girth (measured one metre above ground level) and removing rubbish upto a distance of 50 metres outside the periphery of the area as directed by Engineer-in- Charge: |
| 38 | Earth work in excavation in all kinds of soil by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as specified and directed. |
| 39 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) complete all as specified and directed. |
| 40 | M&L 100mm thick PCC type C-2, (1:3:6) using 40mm graded stone aggregate as in floor etc complete all as specified and directed. |
| 41 | M&L Hardcore of broken stone or boulders gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 42 | M&L Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade with grey cement and pigment over 50mm thick sand cusioning complete all as specified and directed. |
| 43 | Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 44 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 45 | M & L preparation of new cemented/concrete surfaces of any description Surfaces plain or moulded, n exc 10cm width or girth when unconnected with other painting or when painted in a different tint & applying two coats of synthetic enamel paint over a coat of primer complete all as specified |
| 46 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point in soil complete all as specified and directed. |
| 47 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m complete all as specified and directed. |
| 48 | Taking down of Old unserviceable point wiring any type for light, fan, power etc including unserviceable switch,socket, regulator and ceiling rose etc of any make complete including making good disturbed surfaces of walls, floors roof etc complete all as specified and directed. |
| 49 | M&L for one point wiring for lights/fans with PVC insulated FRLSH unsheathed copper cable of size 1.5 sqmm including earth wire of size 1.5 Sqmm in and including Concealed rigid 20 mm dia PVC conduit in and including GI sheet box and white modular Inner/Outer cover plate with frame, for light and fan/call bell including cutting chases for conduit where required and making good to wall and ceiling complete all as specified and as directed . |
| 50 | All as per srl item No 49.00 here-in-before but for 5 pin switch socket outlet 5 Amp on same board. |
| 51 | All as per srl item No 49.00 here-in-before but for 5 pin switch socket outlet 5 Amp independent board. |
| 52 | M&L Wiring for one power socket outlet, 15 amps with 2.5 sq.mm FRLSH PVC insulated copper conductor single core cable in surface / recessed in PVC conduit, with GI Flush box, white modular Inner/Outer cover plate with frame and earthing the point with 2.5 sq.mm FRLSH PVC insulated copper conductor single core cable etc. as required complete all as specified and directed. |
| 53 | S&F Modular switch 1 way 6A, 1 Module complete all as specified and directed. |
| 54 | S&F Modular switch 1 way 16A, 1 Module complete all as specified and directed. |
| 55 | S&F Modular socket 6A 2/3 pin combained 2 module complete all as specified and directed. |
| 56 | S&F Modular socket 6A/16A- 2/3 pin combained 2 module complete all as specified and directed. |
| 57 | S&F SPN sheet metal enclosure for DBs 12 Way double door having 200 Amps rated bus bar 240 Volts AC complete all as specified and directed. |
| 58 | Supply and fixing in replacement of Vertical TPN DB 4 ways with 200 amps rated busbar 415 volt double door including MCCB complete all as specified and directed. |
| 59 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 32 A and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 60 | Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 61 | S&F energy efficient LED light fitting, slim LED panel, surface mounting 2 ftx 2 ft made out of power coated CRCA sheet with acrylic diffuser, constant current output of electronic driver operating voltage range of 150 to 270 volts AC, PF>0.95, high powder LEDs having efficiency of 100-120 lumins/watts, junction temparature less than 85 digree C and TH less than 12 % and CCT 6500K,, CRT>80 suitable for 36 watt LED, LM 80 certified LM, pri wired in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose /connector etc and testing complete all as specified and directed. |
| 62 | M&L in replacement of Wiring for circuit/submain wiring alongwith earth wire of FRLSH PVC insulated copper conductor,single core cable in surface/recessed of size 4X16 sq mm + 1X16 Sq mm earth wire including suitable size of PVC conduit and lugs/thimble with nuts,bollts and washers etc complete including taking down of existing unserviceable wiring complete all as specified and directed. |
| 63 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers complete all as specified and directed. |
| 64 | Supply and Fixing Triple pole and earth enclosure with three pin and earth plug with socket industrial type complete with triple pole MCB of 63 Amp complete all as specified and directed. |
| 65 | Supply, installation, testing and commissioning of Hi wall mounted, high efficient Split type, three Star rating (as per latest rating) of BEE non inverter air conditioner of 2 TR capacity, Machines confirming to latest Indian Standards and suitable for operation on 230 Volts + 10 %, single Phase, 50 Hz AC supply with cooling capacity 6000 watt and cordless remote,AC stand for wall mounted outdoor unit, durecell batteries unit shall comprise of separate Indoor and outdoor unit specified. |
| 66 | a. Indoor (fan coil) unit shall be Wall Mounted type comprising of Fan, Two way air discharge and 2 Row Deep DX coil with finned copper tubes duly coated with anti corrision and thermally conductive coating, T-Flow Fan unit with direct drive Motor , unit shall have proper air circulating, auto mode, auto swing, anti bacteria filtering, ventilation with remote control having Cool/Fan/Dry/Auto mode, sleep mode & on/off timer with suitable thermostat and insulated & leak proof condensate base complete all as specified and as directed by EIC. |
| 67 | b. The outdoor (condensing unit) shall be of Corrosion resistant Galvanized powder coated or equivalent Sheet steel low vibration assembly installed on suitable vibration isolators and comprising of energy efficient hermetically sealed Rotary / Reciprocating compressor operating on R 32/ R 410a refrigerant with copper condenser coils and unit shall have proper insulated & leak proof condensate base. The units shall be installed on M.S channels, angles, flats fram welded structure of appropriate size & thicknesses duly painted with anti corrosive paint (Expoxy , welded structure and anti vibration Isolated pad complete all as specified and as directed by EIC. |
| 68 | Note: (i) 3 mtr Copper pipping duly coated with anticorrision and thermally conductive coating with insulation and PVC flexible copper cable of suitable size as per OEM shall be deemed including in coated rate and if more than 3 mtr copper pipping is required shall be measured and paid seperatly. (ii) Warranty of Split AC unit is 2 Years, Compressor is 10 Years and PCB/controller of is 5 Years (iii) The units shall be installed on MS angle iron frame welded structure (measured and sepatate item) with duly with anti-corrosive paint (Expoxy) and anti vibration Isolated pad. |
| 69 | (iii) The rate should include civil work required to be executed in order to make the Airconditioning system installed & put in working condition. The item includes making holes/gaps in walls to pass duct & pipes, making zaries required for various types of drain, refregerent Civil work required to be executed in order to make the Airconditioning system installed & put in working condition. The item includes making holes/gaps in walls to pass duct & pipes, making zaries required for various types of drain, refregerent & drain water pipes/ lines in walls, floor etc. using cutter machine, including core cutting as per site requirement, refinishing on all the side with rich cement mortar to match the surrounding original finised surfaces to put the entire work in order. While crossing the wall, a heavy duty PVC pipe sleve shall be fixed of the total wall thickness & shall be finished from out with rich cement mortar & from inside with white cement. No extra will be paid for any civil work related to AC work. in walls, floor etc. using cutter machine, including core cutting as per site requirement, refinishing on all the side with rich cement mortar to match the surrounding original finised surfaces to put the entire work in order. While crossing the wall, a heavy duty PVC pipe sleve shall be fixed of the total wall thickness & shall be finished from out with rich cement mortar & from inside with white cement and painting with existing color. |
| 70 | M&L for one point wiring of with PVC insulated FRLSH unsheathed copper cable of size 4.0 sqmm including earth wire of size 4.0 Sqmm in and including Concealed rigid 20 mm dia PVC conduit including GI sheet box and white modular Inner/Outer cover plate with frame, for 15 amps power point including cutting chases for conduit where required and making good to wall and ceiling complete all as specified and as directed. |
| 71 | M&L for sheet metal enclosures with plug top and MCBs single pole and natural enclosures with two pin and earth plug and socket complete with one single pole MCB 32A capacity all as per directed. |
| 72 | Supply & fixing wall mounted Voltage Stablizer, single phase, 50 Hz AC supply with Hi & Low cut off, surge protection, High voltage protection, In-bulit thermal overload protection and ITDS, copper wound with efficiency 95% at nominal load and voltage range input voltage range 140 to 280 volts and output voltage 230 Volt ± 1%, air cooled with digital display complete all as specified and as directed by EIC of 5 KVA Capacity |
| 73 | Supply, installation & testing wall mounted Fan 450 mm in FRP (Fiber reinforced plastic), weather resistant body, copper wound fan motor with three speed single phase, 230V, 50 Hz,with 3 pin plug top complete all as specified and as directed. |
| 74 | Supply and fixing LED street building light fitting 60 Watt 230 V AC PF >0.95, CCT 6500 K, CRT > 80 outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracketwith impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 75 | Material and Labour for earthing complete with GI earth plate 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.5 meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. Steel plate connected with 4 mm GI wire by means of nuts, bolts and washers. GI wire laid in 15 mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) as shown in electrical plat No. 03 of SSR Part-I with following:-(a) 4 mm GI wire upto main DB with 15 mm concealed/surface GI pipe (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits)(c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick re-inforced with 8mm dia bars 75mm centre to centre both ways with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. |
| 76 | Material and Labour for earthing complete with copper plate electrode 600mmx600mmx3.15mm thick burried in ground vertically to a depth not less than 2.5 meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. Copper plate connected with copper earth strip 20x3mm by means of nuts, bolts and washers. Copper strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe and strip up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) as shown in electrical plat No. 03 of SSR Part-I with following:-(a) Copper strip 20x3mm upto test point in 32 mm light grade GI pipe burried in ground or fixed on wall (b) Test point with sheet metal enclosure(b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits)(c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick re-inforced with 8mm dia bars 75mm centre to centre both ways with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. Note: the test report after completion of earthing shall be be submitted to Engineer-in-charge. |
| 77 | M&L copper strip 20mmx3mm fixed on wall with DMC/FRP insulator and burried in floor with GI pipe of 40 mm dia complete all as specified and directed. |
| 78 | Supply,laying, testing and commissionnig of LT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimping type cable lugs in LT panel / MCCB in bldg etc to suit the cable laid in trenches/fixed to poles/drawn through pipes complete of sizes 25 Sqmm 4 core cable complete all as specified and directed. |
| 79 | Supply and Fixing of MCCB 100 Amps,36 KA, 4 Pole,415V, thermal magnetic release complete all as specified and directed. |
| 80 | Supply, installing, testing and commissioning factory fabricated and tested LT outdoor type panel, IP-67/68 rating, platform mounted suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars TPN of capacity 1600 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, and made out of 3.15 mm for load bearing member and 2.00 mm thick CRCA mild steel sheet and mild steel & Mounting Channel frame work made out of angle iron of size 50X50 X6 mm, front opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLSH cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade. The scope of work also comprising of the following:- BUS BAR CHAMBER :- (i) 1600 Amp TPN, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.INSTRUMENT CHAMBER :- (i) Digital Volt Meter, 96X96mm, flush type rated 0-500 V, with Volt meter selector switch- 01 Set. (ii) Digital Amp Meter, 96X96mm, flush type rated 0-1000 A, with Amp meter Selector switch- 01 Set. (iii) C.T's 800/5 A CL 1.0 copper Wound- 01 Set. (Set of three)(iv) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three).(v) Protection MCB 6 A SP C Series- 1 Set. (Set of three). INCOMING SUPPLY :- (a) Main MCCB 800 Amps 50 KA ,microprocessor based release 4 Pole (ICS=100% of ICU) with rotary handlewith 415 volts , 50Hz,=01 No.,Note: Contractor must visit the site before quoting rates. |
| 81 | Supply, installing, testing and commissioning factory fabricated and tested LT outdoor type panel, IP-67/68 rating, platform mounted suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars TPN of capacity 800 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, and made out of 3.15 mm for load bearing member and 2.00 mm thick CRCA mild steel sheet and mild steel & Mounting Channel frame work made out of angle iron of size 50X50 X6 mm, front opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLSH cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade. The scope of work also comprising of the following:- BUS BAR CHAMBER :- (i) 800 Amp TPN, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.Outgoings: (i) MCCB 250 Amp 35 KA, microprocessor based release, 4 Pole (ICS=100% of ICU) with rotary handle 415 volts , 50Hz,=01 No.,(ii) MCCB 200 Amp 35 KA, thermal magnetic release, 4 Pole (ICS=100% of ICU) with rotary handle 415 volts , 50Hz,=01 No., (iii) MCCB 160 Amp 35 KA, thermal magnetic release, 4 Pole (ICS=100% of ICU) with rotary handle 415 volts , 50Hz,=01 No., (iv) MCCB 100 Amp 25 KA, 4 Pole (ICS=100% of ICU) with thermal magnetic release and rotary handle 415 volts , 50Hz,=01 No., (v) MCCB 63 Amp 25 KA, 4 Pole with Fixed thermal magnetic release 415 volts , 50Hz,=05 No. (vi) Danger Plate -01 No (vii) Name Plate for each MCCB (Incoming & Outgoing) |
| 82 | INSTRUMENT CHAMBER :- (i) Digital Volt Meter, 96X96mm, flush type rated 0-500 V, with Volt meter selector switch- 01 Set. (ii) Digital Amp Meter, 96X96mm, flush type rated 0-400 A, with Amp meter Selector switch- 01 Set. (iii) C.T's 400/5 A CL 1.0 Tape Wound- 01 Set. (Set of three)(iv) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three).(v) Protection MCB 6 A SP C Series- 1 Set. (Set of three). INCOMING SUPPLY :- (a) Main MCCB 400 Amps 50 KA , microprocessor based release, 4 Pole (ICS=100% of ICU) with rotary handle 415 volts , 50Hz,=01 No., Outgoings: (i) MCCB 100 Amp 25 KA, 4 Pole (ICS=100% of ICU) with thermal magnetic release and rotary handle 415 volts , 50Hz,=02 No., (ii) MCCB 63 Amp 25 KA, 4 Pole with Fixed thermal magnetic release 415 volts , 50Hz,=06 No., (vi) Danger Plate- 01 No (vii) Name Plate for each MCCB (Incoming & Outgoing) Please Enable Macros to View BoQ information |
| 83 | INSTRUMENT CHAMBER :- (i) Digital Volt Meter, 96X96mm, flush type rated 0-500 V, with Volt meter selector switch- 01 Set. (ii) Digital Amp Meter, 96X96mm, flush type rated 0-400 A, with Amp meter Selector switch- 01 Set. (iii) C.T's 400/5 A CL 1.0 Tape Wound- 01 Set. (Set of three)(iv) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three).(v) Protection MCB 6 A SP C Series- 1 Set. (Set of three). INCOMING SUPPLY :- (a) Main MCCB 400 Amps 50 KA , microprocessor based release, 4 Pole (ICS=100% of ICU) with rotary handle 415 volts , 50Hz,=01 No., Outgoings: (i) MCCB 100 Amp 25 KA, 4 Pole (ICS=100% of ICU) with thermal magnetic release and rotary handle 415 volts , 50Hz,=02 No., (ii) MCCB 63 Amp 25 KA, 4 Pole with Fixed thermal magnetic release 415 volts , 50Hz,=06 No., (vi) Danger Plate- 01 No (vii) Name Plate for each MCCB (Incoming & Outgoing) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail