| 1 | Demolition of cement concrete in ground floors and pavings etc not exc 15 cm thick above or below ground level complete all as specified and directed. |
| 2 | Excavation as in trenches in any type of soil not exceeding 1.5 metres wide and not exceeding 1.5 metres deep lines and getting out complete all as specified and directed by Engineer-in-Charge. |
| 3 | M&L Returning, filling in any type of soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed. |
| 4 | Removing excavated material/Malba to a distance exceeding 1.5 KM and not exceeding 5 KM depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and directed. |
| 5 | M & L for PCC (1:4:8) type D-2 using 40mm graded stone aggregates for foundation filling, mass concrete finished even and rough to receive topping layer completed all as specified by engg in charge. |
| 6 | S&F of TMT bars 10mm dia and over cut to length bend to shape required including cranking bending complete all as specified and directed. |
| 7 | Use and waste of form work to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exceeding 200mm thick surface flat for rough finished surface of concrete complete all as specified. |
| 8 | M&L for RCC work (Nominal Mix) (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in piers, pedestals, tie beams, slabs supported on walls, shelves, man hole cover ,drain covers etc and like complete all as specified and directed. |
| 9 | S&F MS Framed work with MS angle, channels, ISMB, gusset plates, rails, braces,Chequred plates,flat iron, Nut, bolts, rivets, connecting MS plates etc as in Fire exit stair case, barreled iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks, cover grills and similar work etc complete drilled for fixing of steel sheeting or other covering including welding work ,PCC work 1:1.5:3 in grouting etc to be prepared including MS fasteneres, hooks, hinges,necessary holdfasts etc and including all kind of ERW welding, induction butt welding, riveting work and fixing in building upto 12 mtr height complete all as spfd and directed by engr in charge. |
| 10 | M&L for preparation of newly steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. |
| 11 | M&L Cutting openings, through brick walls for door, window and other openings or enlarging existing openings, converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc. to store and rubbish not exc. 50m complete all as specified and directed. |
| 12 | Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work making good with CM 1:6, complete all as specified and directed. |
| 13 | S&F anodised aluminium powder coating aluminium section weighing not less than 0.55Kg/m {minimum thickness of powder coating 50 micron)frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified. |
| 14 | S&F anodised aluminium Powder coating door shutters aluminium section weighing not less than 0.55Kg/m {minimum thickness of powder coating 50 micron) including necessary joining cleats, glazing clips, rubber neoprene packing , hinges,anodised aluminium snap beading screws,all necessary builders hardware etc complete all as specified. |
| 15 | S&F anodised aluminium Powder coating window and ventilator shutters, side hung type without sash bars aluminium section weighing not less tha 0.55Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing , anodised aluminium snap beading screws ,anodised aluminium fittings such as peg stays 150mm long (1no), hinges type B-21 100mm long(2 no.) suitable handle(1 no) including all necessary builders hardare complete all as specified. |
| 16 | S&F 12mm thick particle board exterior grade with decorative prelaminated both sides of approved shades fixed to aluminium shutters/ partitions complete all as specified and directed. |
| 17 | S&F 4.8mm thick sheet glass ordinary quality in Square/rectangle fixed with glazing pins and rubber beading etc in aluminium door/window/partitions etc complete all as specified and directed. |
| 18 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge. |
| 19 | M&L glazed ceramic tiles (300x450/ 300x600) x7 to 8 mm thick coloured tiles in vertical surfaces, wall claddings, boundary wall dado etc set and jointed in neat cement slurry and pointed in white or colour cement to match as in dado over 10mm thick cement plaster in CM (1:4) complete all as specified and directed. |
| 20 | M&L non-skid, ceramic coloured tiles 7 to 8mm thick (Square/rectangular ) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors, set and jointed in cement slurry and pointed in white or coloured cement to match with the shade of tiles over and including screed bed 15mm thick average in cement mortar 1:6 complete all as specified & as directed. |
| 21 | M&L vitrified ceramic tiles light shade 8 mm to 9 mm thick (square/rectangular) polished,area of each tiles exc 0.16 sqm but n.exc 0.36 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 22 | Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars, arches etc complete all as specified and directed. |
| 23 | M&L for brick work straight or curved on plan exc 6m mean radius in cement mortar (1:4) with Sub class ‘B’ brick including manhole raising, footpath, etc complete all as specified and as directed by Engineer-in-Charge. |
| 24 | Taking down cement plaster/grit plaster any description on brick/concrete surfaces etc including raking out joints hacking for key, scrubbing down with water etc complete all as specified and as directed. |
| 25 | M&L 15mm thick rendering in cement mortar 1:6 on fair faces of new or old brick works or concrete work finished even & smooth without using extra cement complete all as specified and directed. |
| 26 | M&L 15mm thick rendering in cement mortar 1:4 on other than fair faces of new or old brick work or concrete work, finished even & smooth without using extra cement complete all as specified and as directed. |
| 27 | M&L preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper (white or tinted) over a coat of alkali resistant primer complete all as specified and directed. |
| 28 | M&L for preparation of newly plastered or unplastered wall surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. |
| 29 | M&L for Complete removal of existing treatment including preparation of plastered or unplastered old decorated surfaces of walls incl pillasters and cornices etc. incl washing, rubbing down and stopping the previously treated surfaces and applying two coat of oil emulsion distemper of approved shade/tint over and including one coat of 1 mm thick birla wall care putty to achieve smooth finish complete all as specified & directed. |
| 30 | M&L for Complete removal of existing treatment including preparation of plastered or unplastered old decorated surfaces of walls incl pillasters and cornices etc. incl washing, rubbing down and stopping the previously treated surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. Note:- This item includes use of necessary scaffolding and safety net up to G+5 storey building. |
| 31 | M&L for PCC type B1 1:2:4 (using 20mm graded agg) in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers apexstone, bed plates, including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 32 | Taking down chowkhats or frames with shutters ( without taking of shutters from the frame area exc 1.50 sqm but not exc 4 sqm.all as directed. |
| 33 | M&L for 1st class HW (Sangwan) plain , solid, straight chowkhat and frame, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed including making good all as specified and directed by Engr-in-Charge |
| 34 | S&F 40mm thick designer solid wooden door (1st class hardwood Sangwan) with any number of panels complete all as specified and directed. |
| 35 | M&L two coats of French Polishing on new wooden surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler all as specified and directed. |
| 36 | M&L two coats of French Polishing on old wooden surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler all as specified and directed. |
| 37 | S&F in repair 100 mm stainless steel butt hinges fixed to the frame complete all as specified by the manufacturer and as per directions of Engineer-in-charge |
| 38 | S&F in repairs 150 mm long stainless steel chrome finish SS Door handle complete all as specified and directed. |
| 39 | S&F in repairs 200 mm long SS tower bolts of extruded section complete all as specified and directed. |
| 40 | S&F in repair Mortice lock assembly verticle type with one set of lock Handles SS for fixing on both sides of wooden flush door, including 4 lever lock of required size complete all as specified and directed. |
| 41 | Supply & fixing as in repair aluminium alloy body floor door stopper of size 75m having double round legs for better grip ,with rubber base fixed to door shutters with countersunk screws complete all as specified and directed. |
| 42 | S&F in repair door closer hydraulically regulated, aluminium body designation No 3, universal type, suitable for door shutter of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed. |
| 43 | M&L for brick work straight or curved on plan exc 6m mean radius in cement mortar (1:6) with Sub class ‘B’ brick complete all as specified and as directed by Engineer-in-Charge. |
| 44 | Dismentling of stone slabs old granite as in plateform /pillers of any description or thickness in floors, aprons etc. Laid, bedded and pointed in any mortar complete all specified and directed. |
| 45 | Material and labour for 18-20mm thick granite stone slab as in window cill/pillers/ or platform,machine cut bedded and jointed with grey cement slurry and pointed with white cement with admixtur of pigment to match the shade of granite stone including grinding/moulding and polishing laid over 15 mm thick sereed bed in CM 1:4 etc complete all as specified and directed |
| 46 | S&F MS framed work such as in grills,grating etc with ends of bars conforming to Fe--290 Gde-E-165 all as specified and directed. |
| 47 | M&L for preparing new steel surfaces over 10 cm width or girth & applying two coats of synthetic enamel paint over a coat or red oxide primer complete all as specified and as directed. |
| 48 | M&L 5mm thick rendering in cement mortar 1:3 on ceiling new or old brick works or concrete work finished even & smooth without using extra cement complete all as specified and directed. |
| 49 | M&L preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper (white or tinted) over two coat of wall care putty (Avg 1mm thick) complete all as specified and directed. |
| 50 | M&L preparation of newly plastered surfaces of ceiling and applying two coat of oil bound distemper(white or tinted) over two coat of wall care putty (Avg 1mm thick) complete all as specified and directed. |
| 51 | M&L for Complete removal of existing treatment from internal plastered or unplastered surfaces of walls and applying two coats of oil bound distemper on walls over and including 2 coat of wall care putty (Avg 1mm thick) on scrapped/uneven surfaces of any description to match with the existing surfaces before application of paint etc complete all as specified and directed. |
| 52 | M/L Powder coated aluminum windows made out of aluminum tubular frame of section 63.5 x 38.10 x 1.6 mm thick and shutter fixed ,sliding or openable horizontal and vertical members of alum anodized section 47.50 x 44.45 x1.6 mm thick, aluminum beading, rubber gasket and complete aluminum fittings such as hinges tower bolt, stay rod and handle ( sheet glass shall be measured and paid separately) Design and pattern of aluminum windows shall be as approved . |
| 53 | S&F 4.80mm thick tinted glass fixed to aluminium door /window /partitions etc of any size complete all as specified and directed. |
| 54 | S&F Anodised aluminium grills(anodised transparent or dyed to required shade according to IS:1868 with aluminium anodic coating of grade AC 15) of approved design and pattern with approved standared sections and fixed to windows/ventilators frame with CP brass/stainless steel screws @200mm C/c including cutting the grill to propper opening size for fixing and operation of handles and fixing approved anodised aluminium standared section aruond the opening complete all as specified and directed. |
| 55 | Dismentling boarding, any description, fixed in any positioin with nails complete all as specified |
| 56 | Providing and fixing tiles false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking GI metal grid of hot dipped galvanized steel sections consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture having 8 to 10 mm thick square edge PVC Laminated Gypsum board Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge |
| 57 | Material and Labour for preparation of old decorated surfaces of wall (plastered or un-plastered) including cornices, pilaster etc by brooming down with steel wire brushing, scraping down, smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat distemper oil bound emulsion (white or tinted) on walls complete all as specified and directed. |
| 58 | S&F collapsible steel doors of size Exc 4 Sqm each on rollers,chennels,reveted portion for smooth opening/closing complete all as specified and as directed. |
| 59 | M&L for removing excavated material/debris/Malba exc. 1.50 km but n exc. 5 km and depositing where directed Please Enable Macros to View BoQ information |