|
| 1 | Supplying, installing, testing and commissioning 25 HP monoblock pump KDI -2560+SSIMS IP55 FCL suction and delivery size 100 mm X 80 mm, 2930 RPM, Head range 65m with CI impeller, CI casing and CS shaft with energy efficient level 2, induction motor conforming to IS:12615, capacity suitable for working voltage 415 volts, 3 phase, 50 Hz, including all necessary electric connection from starter to pump including 3 core multi standard copper conductor of size 25 sqmm of 10 running metre with lugs complete all as specified and as directed. |
| 2 | Supplying, installing, testing and commissioning 15 HP monoblock pump single stage,KDT-CI Series water dischargeflow rate 11.3-3.2LPS suction delivery size 65 mm X 65 mm, 3000 RPM,MB/MI series Head Range- 51-72 Mtr with CI impeller, CI casing and CS shaft with energy efficient level 2, induction motor conforming to IS:12615, capacity suitable for working voltage 415 volts, 3 phase, 50 Hz, including all necessary electric connection from starter to pump including 3 core multi standard copper conductor of size16sqmm of 10 running metre with lugs complete all as specified and as directed. |
| 3 | Supplying, installing, testing and commissioning125 mm bore 10 HP submercible pump set delivery size 40 mm 2900 RPM, Head range 75 m with CI impeller, CI casing and CS shaft with energy efficient level 2, induction motor conforming to IS:12615, capacity suitable for working voltage 350-440 Volts , 3 phase, 50 Hz, including all necessary electric connection from starter to pump including 3 core multi standard copper conductor of size10 sqmm of 10 running meter with lugs,clamps complete all as specified and as directed. |
| 4 | Supplying, installing, testing and commissioning Bore size125 mm series 7.5 HP submercible pump set delivery size50mm 2900 RPM, Head range 32-66 mtr stagewith CI impeller, CI casing and CS shaft with energy efficient level 2, induction motor conforming to IS:12615, capacity suitable for working voltage 350-440 Volts , 3 phase, 50 Hz, including connection of starter, including all necessary electric connection from starter to pump including 3 core multi standard copper conductor of size 6 sqmm of 10 running meter with lugs,clamps complete all as specified and as directed. |
| 5 | Supplying, installing, testing and commissioning Bore size125 mm series 5 HP submercible pump set delivery size50mm 2900 RPM, Head range 20-41 mtr 5 stage with CI impeller, CI casing and CS shaft with energy efficient level 2, induction motor conforming to IS:12615, capacity suitable for working voltage 350-440 Volts , 3 phase, 50 Hz, including all necessary electric connection from starter to pump including 3 core multi standard copper conductor of size 4 sqmm of 10 running meter with lugs ,clamps complete all as specified and as directed. |
| 6 | Supplying, installing, testing and commissioning Bore size125 mm series 5 HP submercible pump set delivery size50mm 2900 RPM, Head range 65-330 mtr 5 stage with CI impeller, CI casing and CS shaft with energy efficient level 2, induction motor conforming to IS:12615, capacity suitable for working voltage 350-440 Volts , 3 phase, 50 Hz, including connection of starter, including all necessary electric connection from starter to pump including 3 core multi stranded copper conductor of size 4 sqmm of 10 running metre with lugs, clamps complete all as specified and as directed. |
| 7 | Disconnection of submersible pump set of any size from existing system water supply & electrical and Taking out /Uplifting the U/S pump set from deep borewell with disconnected from lowering pipe line of any size with manual or suitable electric driven chain pully upto 420 ft depth and lowering the new submercible pump set in same borewell complete all as specified and directed.Note:- i) pump motor/submercinle pump set will be paid separately.(ii) All type of T/P such as chain pully required to complete the job will be arranged by contractor.(iii) Job will be done round -o-clock continued as per site requirement as directed by AGE.(iv) Delay in job will be charged on the basis of Rs. 500/- per hour.(v) Items required for motor connection such as PVC insulation tape, valcanised rubber / puncture tube etc will be provided by the contarctor to complete the work and rate as deemed to be quoted in unit rate no extra payment will be made to the contractor. |
| 8 | Disconnection of centrifugal/ monoblock pump set of any size from existing system water supply & electrical and Taking out /Uplifting the U/S pump set from pump house,etc with disconnected from lowering pipe line and lowering the new centrifugal pump set in same pump house complete all as specified and directed.Note:- i) pump motor/submercinle pump set will be paid separately.(ii) All type of T/P such as chain pully required to complete the job will be arranged by contractor.(iii) Job will be done round -o-clock continued as per site requirement as directed by AGE.(iv) Delay in job will be charged on the basis of Rs. 500/- per hour.(v) Items required for motor connection such as PVC insulation tape, valcanised rubber / puncture tube etc will be provided by the contarctor to complete the work and rate as deemed to be quoted in unit rate no extra payment will be made to the contractor. |
| 9 | S&F of submersible flat copper stranded cable 1100 Volt grade of size 4sqmm 3 core complere all as specified and directed. |
| 10 | S&F of submersible flat copper stranded cable 1100 Volt grade of size 6 sqmm 3 core complere all as specified and directed. |
| 11 | S&F of submersible flat copper stranded cable 1100 Volt grade of size 10 sqmm 3 core complere all as specified and directed. |
| 12 | S&F of submersible flat copper stranded cable 1100 Volt grade of size 16 sqmm 3 core complere all as specified and directed. |
| 13 | S&F of submersible flat copper stranded cable 1100 Volt grade of size 25 sqmm 3 core complere all as specified and directed. |
| 14 | Supply and fixed soft staretr XS4000 ,24A, Mains : 200-525VAC , Control :110/220VAC , Inside delta( 6 Wire Control) Connection , control inputs (2 x fixed, 2 x programmable) , Relay outputs (1 x fixed, 2 x programmable)Analog output -1 , IE3 compatible , 99% energy efficient when running ,Motor thermistor Protection electric motar 5 HP including necessary connection and fixed on Suitable size stand,box etc complete all as specified and as directed. |
| 15 | Supply and fixed soft staretr XS4000 ,24A, Mains : 200-525VAC , Control :110/220VAC , Inside delta( 6 Wire Control) Connection , control inputs (2 x fixed, 2 x programmable) , Relay outputs (1 x fixed, 2 x programmable)Analog output -1 , IE3 compatible , 99% energy efficient when running ,Motor thermistor Protection electric motar 7.5 HPto 10 HP including necessary connection and fixed on Suitable size stand,box etc complete all as specified and as directed. |
| 16 | Supply and fixed soft staretr XS4000 ,24A, Mains : 200-525VAC , Control :110/220VAC , Inside delta( 6 Wire Control) Connection , control inputs (2 x fixed, 2 x programmable) , Relay outputs (1 x fixed, 2 x programmable)Analog output -1 , IE3 compatible , 99% energy efficient when running ,Motor thermistor Protection electric motar 12.5 HP to 15 hp including necessary connection and fixed on Suitable size stand,box etc complete all as specified and as directed. |
| 17 | Supply and fixed soft staretr XS4000 Soft Starter ,42A, Mains : 200-525VAC , Control :110/220VAC , Inside delta( 6 Wire Control) Connection , control inputs (2 x fixed, 2 x programmable) , Relay outputs (1 x fixed, 2 x programmable)Analog output -1 , IE3 compatible , 99% energy efficient when running ,Motor thermistor Protection electric motar 25 to 30 hp including necessary connection and fixed on Suitable size stand etc complete all as specified and as directed. |
| 18 | Supply and laying galvanised steel water tubing of medium grade of dia 40mm with and including all fittings such as bends, elbows, tees, unions, niples, short pieces etc as required at site laid in trenches complete all as specified and directed. |
| 19 | Supply and laying galvanised steel water tubing of medium grade of dia50 MM with and including all fittings such as bends, elbows, tees, unions, niples, short pieces etc as required at site laid in trenches complete all as specified and directed. |
| 20 | Supply and laying galvanised steel water tubing of medium grade of dia 80mm with and including all fittings such as bends, elbows, tees, unions, niples, short pieces etc as required at site laid in trenches complete all as specified and directed. |
| 21 | Supply and laying galvanised steel water tubing of medium grade of dia 100 mm with and including all fittings such as bends, elbows, tees, unions, niples, short pieces etc as required at site laid in trenches complete all as specified and directed. |
| 22 | Supply and laying galvanised steel water tubing of medium grade of dia 150 mm with and including all fittings such as bends, elbows, tees, unions, niples, short pieces etc as required at site laid in trenches complete all as specified and directed. |
| 23 | Material and Labour of Bends. Tapers. Tee pieces (single & double branch) any type and angle/radius and straight connecting pieces but all ends flanged |
| 24 | S & F clamp for housing/ casing pipe, made of flat iron of hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 and as per IS 2800: 2019 including necessary bolts & nuts of required size complete all as specified and as directed. |
| 25 | S & F bail plug/ bottom plug with hook, 150 mm size, made of material as per IS 4270: 2001, conforming to IS 2800: 2019 complete all as specified and as directed. |
| 26 | S & F made of flat iron angle/chnnel for foundation of centrifugal pump, monoblock pump bar of hot rolled medium and high tensile structural steel of grade E 250 quality C conform ing to IS 2062: 2011 and as per IS 2800: 2019 including necessary bolts & nuts & welding of required size,including PCC work complete all as specified and as directed. |
| 27 | Supply and fixing of Nylon Heavey duty Rope for holding submersible pump set/column pipe including pipe including necessary holding mild steel clamp nuts, bolts etc. complete all as directed. |
| 28 | Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit ndot less than 2.25 mtrs deep below ground level) with top edge of the earth plate at a depth of not less than 1.5 mtr below ground level connected to galvanized iron strip 25 x 4 mm as earthing lead by means of bolts, nuts and washers made out of GI/steel earth strip protected by GI light grade pipe of 40 mm dia and connecting to main panel board/switch board/control board all shown in electrical plate No 3 of SSR Pt I incl PCC chambers in 1:2:4 and RCC cover slab with 8mm dia MS bars reinforced at 10 cm center to center both ways incl earth work like excavation, returning filling back disposal etc complete. |
| 29 | M & L for construction of new valve chamber of size 900 mm X 900 mm X 900mm with burnt brick (Sub class B) including necessary earth work in any type of soil, PPC foundation (1:4:8) type D-2 20 mm grade stone aggregate as in base concrete, brick work in CM 1:4 with 10 mm thick plaster internally and 15 mm thick externally in CM 1:4, 4 mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made out of 40 mm X 40 mm X 6 mm MS angles complete with 2 coats of synthetic enamel paint over one coat of red oxide prime on all metal works & three coats of white wash on all plastered surfaces of valve chambers complete all as specified & directed by Engineer-in-Charge. |
| 30 | Supply and install of iron sluice valve ISI marked 50 mm dia class PN 1.6 flanged with gun metal spindle including all fittings such as nuts , bolts, washers tec with iron wheel confirming to IS: 780/14846 complete in all respect all as specified. |
| 31 | Supply and install of iron sluice valve ISI marked 80 mm dia class PN 1.6 flanged with gun metal spindle including all fittings such as nuts , bolts, washers tec with iron wheel confirming to IS: 780/14846 complete in all respect all as specified. |
| 32 | Supply and install of iron sluice valve ISI marked 100 mm dia class PN 1.6 flanged with gun metal spindle including all fittings such as nuts , bolts, washers tec with iron wheel confirming to IS: 780/14846 complete in all respect all as specified. |
| 33 | Supply and install of iron sluice valve ISI marked 150 mm dia class PN 1.6 flanged with gun metal spindle including all fittings such as nuts , bolts, washers tec with iron wheel confirming to IS: 780/14846 complete in all respect all as specified. |
| 34 | M & L flanged reflux valves(ISI Marked) of single door, swing check type (non return valves) of nominal pressure (PN 1.6) as per IS 5312 (Part 1): 2004, nominal size 80 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed. |
| 35 | Supply and install of NRV CI reflux valve (non return valve ISI 5312) of size 100 mm bore , heavy duty both end flanged of pressure rating PN- 1.6 and joint with rubber or biber board gasket complate with and including including complete fixing accessories like nut, bolt, washers, packing etc and all as specified and directed by Engr-in-Charge. |
| 36 | S & F foot valve conformimg to GM0200, 40mm dia, complete all as specified and as directed. |
| 37 | S & F foot valve conformimg to GM0200, 50mm dia, complete all as specified and as directed. |
| 38 | S & F foot valve conformimg to GM0200, 90mm dia, complete all as specified and as directed. |
| 39 | Supply and fixing of colum pipe 40mm bore both end flanged made out GI tubing medium grade welded at end of colum pipe cuttung of groove to house submercible cable 3 core length of each colum pipe not exceeding 3.10 meter complete all as specified and as direcetd. Please Enable Macros to View BoQ information |