| 1 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for trench of cable/foundation of pole and stay etc and getting out in hard/dense soil complete all as specified and as directed. |
| 2 | All as per Srl item No 01 but beyond 1.5 mtr depth and getting out complete all as specified and as directed. |
| 3 | Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed. |
| 4 | Removal of surplus soil to a distance not exceeding 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and as directed. |
| 5 | Supplying and laying sand cushioning for cable proction in trenches/ cable duct 8 cm before laying cable and 15cm deep over the cable complete all as specified and as directed.Note- Punned thickness of 18Cm shall be considered for measurement purpose |
| 6 | Supply and laying brick for protection ofcable sub class ,B, laid dry flat across the cable with lenth of hole brick complete all as specified and as directed. |
| 7 | Supply & laying HT XLPE Cable, insulated, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, conforming to IS:7098 (Part II), 11 KV, ‘Earthed Grade, cross-sectional area 95 Sqmm 3 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/under Road including Testing, complete all as specified and as directed. |
| 8 | Supply and jointing heat shrinkabble and termination end joints for 11 KV XLPE cable size 50 Sq mm to 95 Sq mm 3 core end joint kit Outdoor type complete all as specified and as directed. |
| 9 | Supply, laying and fixing Medium grade galvanised iron pipe IS : 1239 marked with all fittings fixed on wall / poles, crossing of road etc for protection of cable complete all as specified and as directed. |
| 10 | All as per Srl item No 09 but 80 mm nominal bore complete all as specified and as directed. |
| 11 | Supply, erection and fixing in true vertical position steel tubler swaged pole 11 mtr long type (410-SP-55) conforming to IS -2713 (part 1 and 2) - 1980 complete with cast iron base plate, pole cap, MS bolts, nuts and screws, welded and reduced section and lonitudinal weld seam throughout entire length of pole including material and labour for 2 coats of black bituminous paint throughout internally and externally upto planting depth and remaining exterior position of pole with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed. |
| 12 | M&L plain cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in base of ple or in any suitable complete all as specified and as directed. |
| 13 | M&L plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation or in any situation complete all as specified and as directed. |
| 14 | Material and labour for PCC 1:2:4 type B1 using 20 mm grade stone aggregate as in copping of existing and new electric pole at site including providing necessary form work complete all as specified and as directed. |
| 15 | S&F disc insulated porcelain vitreous 145 mm heigh 255 mm dia ball and socket type white / brown or green single disc assembles for tension with tension GI clamps for conductors working pressure 11 KV complete all as specified and as directed. |
| 16 | Supply and fixing pin type insulator porcelain vitreous with brown of green including one galvanised mild steel spindle two galvanized iron washer and galvanized iron nut, 150 mm height and 150 mm dia 11000 volt grade complete all as specified and as directed. |
| 17 | Loop type insulator, vitreous white, brown or green large size with overall dimension 90x140mm with clearance of hole 25.5mm complete all as specified and as directed. |
| 18 | M&L for stay assembly 300x300x3 mm complete with accessories such as GI stay bow 20mm dia 400 mm long, GI stay plate 300x300x3 mm stay road 20mm dia 1800 long GI nuts,bolts loop insulator MS clamps necessary excavation PCC work (loop insulator PCC work MSClamp to pole excavation and earth work will be measured & paid separately as shown in electrical plate No. I complete all as specified and as directed. |
| 19 | M&L for galvanised stay wire stranded 7/4 Or 7/3.15 mm complete all as specified and as directed. |
| 20 | Air break, gang operated with DO fuse of 12 Nos insulators outdoor type, Triple pole mechanically operated, suitable for vertcal installation, Single break, provided with locking arrangements consisting of MS channel, HT Post type insulator copper alloy, high Pressure, Assembly operating rod 25 mm dia GI pipe medium grade for operating from 1.2 m above GL complete confirming to IS -1318 of 1972 rated voltage 11 KV & for current rating 200 Amp complete all as specified and as directed. |
| 21 | Supply and fixing cross, arms bracing supports clamps back plates fabricated from structural steel sections including nut bolts washers welding bending cold or hot drilling holes for bolts in any shape and size and incidcated or directed and inclusive of two coats of aluminium paint over primer coat complete all as specified and as directed. |
| 22 | M&L for Aluminium conductor steel reinforced any size (directed and recommended size of current rating) on poles including binding wire and appropriate size complete all as specified and as directed. |
| 23 | M&L danger notice plate of 1.60 mm thick mild steel sheet vitreous enamelled white with letters, figures and convertional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approval size for 25x20 cm size complete all as specified and as directed.for HT 11000 volts |
| 24 | Materials and Labour for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.5M below normal ground level connected to galvanised earth lead wire but using galvanised iron strip 32×6 mm as earthing lead by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm (Reinforced with 8 mm dia. TMT bars @ 150 mm, center to center both ways) with one handle for lifting made out of 8 mm dia. MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing light grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown on lectrical plate No 3 of SSR Part-I (2009) complete all as specified and as directed. |
| 25 | S&F of Lightning Arrester Expulsion type complete with all Fittings Transmission Class discharge capacity 65 KA suitablefor working pressure of 11000 Volts , complete all as specified and as directed. |
| 26 | S&F Galvanised Steel Wire 3.15 or 4.0mm dia as Earth Continuity Conductor and fixed to Pole, binding with Aluminium Binding Wire, complete all as specified and as directed.NOTE : Cost of Binding Wire will deem to be included in the Quoted Unit Rate. |
| 27 | Materials and Labour for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.5M below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm (Reinforced with 8 mm dia. TMT bars @ 150 mm, center to center both ways) with one handle for lifting made out of 8 mm dia. MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing light grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as specified and as directed. |
| 28 | Supply and fix Cable path indicator with cast iron plate 100mm dia, 5mm thick engraved with HT Cable of size as provided fixed on angle iron frame of size 40 X40 X6 mm, 40 cm long by means of bolts, nuts, washer ,or welding and embedded in PCC 1:3:6, Type C2 block of size 15 X15 X20 CM including excavation complete all as specified and as directed. Please Enable Macros to View BoQ information |