| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLSH PVC insulated copper conductor single core cable etc as required complete all as specified and as directed. |
| 2 | M&L Wiring for one 3 pin socket outlet, 5 amps, independent with 1.5 sq.mm FRLSH PVC insulated copper conductor single core cable in surface / recessed in PVC conduit, with GI Flush box and earthing the point with 1.5 sq.mm FRLSH PVC insulated copper conductor single core cable etc. as required complete all as specified and as directed. |
| 3 | M&L Wiring for one power socket outlet, 15 amps with 2.5 sq.mm FRLSH PVC insulated copper conductor single core cable in surface / recessed in PVC conduit, with GI Flush box and earthing the point with 2.5 sq.mm FRLSH PVC insulated copper conductor single core cable etc. as required complete all as specified and as directed. |
| 4 | Supply and fixing in replacement of 3 module modular base and cover plate on existing modular metal boxes as required complete all as specified and as directed. |
| 5 | Supplying and fixing 05/06 Amp modular switch on the modular plate & switch box including connections but excluding modular plate etc. as required complete all as specified and as directed. |
| 6 | Supplying and fixing 15/16 Amp modular switch on the modular plate & switch box including connections but excluding modular plate etc. as required complete all as specified and as directed. |
| 7 | Supplying and fixing 05/06 Amp modular Socket outlet 3 pin 5/6 Amp including connections but excluding modular plate etc. as required complete all as specified and as directed. |
| 8 | Supplying and fixing 15/16 Amp modular Socket outlet 6 pin 15/16 Amp including connections but excluding modular plate etc as required complete all as specified and as directed. |
| 9 | M&L for sub main wiring 2x4.0 sqmm and 1x4 Sqmm earth wire PVC insulated FRLSHH multistranded copper conductor ISI marked 1100 V grade including PVC conduit or fixed in wall/floor, passing through wall/ceiling complete all as specified and as directed. |
| 10 | Supply and fixing Single pole and neutral enclosure with a two pin and earth plug and socket & top plug complete with one single pole MCB 20 Amps complete all as specified and as directed. |
| 11 | Supplying, installation, Testing & Commissioning of recessed Panel light 2x2 ft., of following body material and construction as per IS: 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.20.95, IP20, CRI ≥80, UGR (Unified Glare Rating) ≤ 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry, of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K- / 5700°K 16500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 Sqmm FRLSH/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required .System lumen efficacy 2105<120 Im/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness ≥ 1.20 mm) |
| 12 | Supply and fixing energy efficient LED light fitting surface mounted 4' long, 20 watt, 240 volts, 50 hz made out of extruded aluminium housing with acrylic diffuser, LM 80 certified LED, constant current out put of electronic driver of operating voltage 140v to 270v and temperature - 10 degree centigrade to 50 digree centigrade with ingress protection IP 20 duly pre wired with insulated copper wire, PF>0.95 with efficiency ≥120 lumins/watt and TDH less than 10%, CRI≥80 digree , CCT 6500 K in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose complete all as specified and directed. |
| 13 | Supply and Fix Wall mounted fan of blade sweep size 450 mm ,230 V, 50 Hz of motor speed 1350 RPM and air flow 60 CFM with 03 numbers of speed settings, all as specified and directed. |
| 14 | Supply and fix 1200 mm service value ≥ 6.0 CM/Min/Watt , air delivery 210CM/Min (minimum) ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body.Power Factor not less than 0.9, Service Value CM/M/W) minimum as below, 350 RPM (tolerance as per IS: 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 °C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLSH/HFFR PVC insulated copper conductor single core cable and earthing etc as required complete all as specified and as directed. |
| 15 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with motor, louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300 mm complete all as specified. |
| 16 | Supply and fixing of 8 ways surface/ recess mounting, horizontal type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required |
| 17 | Supply and fixing MCB 4 P 40 A to 100 A in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 18 | M&L of Wiring for circuit/submain wiring alongwith earth wire of FRLSH PVC insulated copper conductor,single core cable in surface/recessed of size 4X16 sq mm + 1X16 Sq mm earth wire including suitable size of PVC conduit and lugs/thimble with nuts, bolts and washers etc complete including taking down of existing unserviceable wiring complete all as specified and directed. |
| 19 | S&F IP-43, protection metal double door Vertical TPN -DB rated busbar, 415 volts, 50 HZ complete with interconnection links, blanking plates, cable ties, identification labels TPN 12 way, 24 modules suitable for accommodating 100 Amps MCCB 4 pole as incomer and SP/TP MCB as out going and concealed /surface on wall as per site requirement including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified and directed. |
| 20 | Supply and fix MCCB 125 amps TPN, 36 kA, 240 V, 50 Hz, C curve thermal magnetic release, ICS=100% ICU C series complete all as specified and directed |
| 21 | S&F ceiling rose 3 terminal/PVC/polycarbonate, isolated body 6A complete all as specified. |
| 22 | Supply and fixing, 240V, 50 hz, 10 KA 'C' curve MCB SP 6 to 32 Amps current carrying capacity in the MCB DB in and including necessary cable connection with copper thimbles complete with connection testing and commissioning complete all as specified and directed. |
| 23 | Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.5 meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron wire 4 mm dia by means of Copper nuts, bolts and washers, laid in 40 mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following:- (a) GI wire 4 mm dia. (b) Watering pipe GI light grade 20 mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. |
| 24 | Supply and fixing Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or drawn in conduit or any other indicated situation etc. as required 4 mm dia galvanised iron wire complete all as specified and directed. |
| 25 | Supply,laying, testing and commissionnig of LT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminium conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimping type cable lugs in LT panel / MCCB in bldg etc to suit the cable fixed on wall through DLP UPVC trunking of sizes 50 Sqmm 4 core complete all as specified and directed |
| 26 | S&F DLP U-PVC trunking system size 100x50 mm in and including such as bend, fittings etc. and flexible cover complete all as specified and directed. |
| 27 | Taking out split type AC/Window type AC complete indoor and outdoor unit from any height of building by including pumping down the gas into the compressor by controlling the suction and discharge valves , disconnecting the suction and discharge copper piping and refixing after renovation complete all as specified and directed. |
| 28 | Excavation in post holes or similar holes in any kind of soil n. exc 1.50 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers n. exc. 25 cm, watering and removing surplus soil outside MoD land complete all as specified. |
| 29 | M & L cement concrete (1:4:8) type E-2 using 40mm graded stone aggt as in foundation filling, mass concrete and sub floors etc. complete all as specified. |
| 30 | S &F structural steel work with MS hollow tubes square, round, rectangular as in tubular trusses, vertical posts, purlins, rafters, framed work in truss, gusset plates, connecting plates, bracing etc upto 08 mtr height including necessary nuts, bolts, rivets, special shaped washer, self machine SS screws etc. complete using ERW or induction butt welded tubes conforming to I.S.1161 complete all as specified. |
| 31 | S&F MS Framed work with MS angle, channels, ISMB, gusset plates, rails, braces,Chequared plates,flat iron, Nut, bolts, rivets, connecting MS plates etc as in Fire exit stair case, barreled iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks, cover grills and similar work etc complete drilled for fixing of steel sheeting or other covering including welding work ,PCC work 1:1.5:3 in grouting etc to be prepared including MS fasteneres, hooks, hinges,necessary holdfasts etc and including all kind of ERW welding, induction butt welding, riveting work and fixing in building upto 12 mtr height complete all as spfd and directed by engr in charge. |
| 32 | M & L mild steel work for flat iron fillets as in wind ties for roof coverings including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified. |
| 33 | M&L for Preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer, fixed complete all as specified and directed. |
| 34 | S&F 12mm thick 4 layer and 3 cell polycarbonate translucent sheet with each cell thickness not less than 4.0 mm having UV protection 40 micron coating on both sides and weight not less than 2.50 kg/ sqm in any color and shade as approved fixed with double tooth locking polycarbonate connector, SS cleats, end cap, aluminium end cap for sheet, fixed as in roof sheeting in any shape including aluminium profile strip and suitable alumunium L shape clit for edges of roof sheet and all necessory assescories complete all as specified and directed. |
| 35 | Dismantling of Asbestos cement (corrugated semicorrugated etc ) sheets in roof covering complete all as specified . |
| 36 | Supply and fixing Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering, cladding to wall, ridges etc. fixed all as per manufacturers instructions and fixed with self thread making steel screws of length not less than 50mm complete all as specified & directed by engr-in-charge. |
| 37 | Supply and fixing Pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, ridges, flashing, eaves board valley gutter of any shape etc, cut to designed shape (Jhhallar) as directed at site fixed all as per manufacturers instructions and fixed with self thread making steel screws of length not less than 50mm complete all as specified & directed by engr-in-charge |
| 38 | Demolition of cement concrete in ground floors and pavings etc not exc 15 cm thick above or below ground level complete all as specified and directed. |
| 39 | Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars, arches etc complete all as specified and directed. |
| 40 | M&L for brick work straight or curved on plan exc 6m mean radius in cement mortar (1:4) with Sub class ‘B’ brick including manhole raising, footpath, etc complete all as specified and as directed by Engineer-in-Charge. |
| 41 | M&L 15mm thick rendering in cement mortar 1:4 on other than fair faces of new or old brick work or concrete work, finished even & smooth without using extra cement complete all as specified and as directed. |
| 42 | M&L for preparation of newly plastered or unplastered wall surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed |
| 43 | Supply and fixing factory made chequared cement concrete coloured tiles (250mm x 250mm/ 300mmx300mm) x 22 to 24 mm thick, set jointed and pointed in neat cement slurry with grey cement mixed with pigment to match the colour of tiles, laid over and incl 20mm thick screed bed in CM 1:4, complete all as specified & directed. |
| 44 | M & L for PCC (1:4:8) type D-2 using 40mm graded stone aggregates for sub bases of floor, mass concrete finished even and rough to receive topping layer completed all as specified by engg in charge. Please Enable Macros to View BoQ information |