| 1 | Item Rate BoQ 1.0 BoQ_Ver4.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: COMMANDER WORKS ENGINEER,CHENNAI Name of Work: CONSTRUCTION OF MANHOLES AND RE-LAYING OF SEWAGE LINES IN DOMESTIC AREA AT 23 ED AF STN UNDER GE AVADI Contract No: CWE/AVD/ OF 2026-2027 Name of the Bidder/ Bidding Firm / Company : SCHEDULE 'A'(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of items Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT With Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | M&L for demolition of cement concrete concrete (unreinforced concrete) of any description in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified. |
| 3 | M&L for plain cement concrete 1:4:8 type D2 (using 40 mm graded granite stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 4 | M&L for 60 mm thick machine pressed rubber moulded precast concrete interlocking paver block, factory manufactured (ISI Marked) of any shape and size as approved by GE ,conforming to IS 15658-2006 of M-35 Grade,casted with grey cement and top layer with grey cement & without pigment as in floor,pavement,etc complete all as specified and directed. |
| 5 | M&L for stone dust filling under floor ,pavers block as a cushioning including watering and consolidation complete all as specified and directed. |
| 6 | M&L for Chequered cement concrete coloured machine pressed tiles of size 250mm x 250mm x 22mm thick with grey cement, set jointed & pointed in neat cement slurry and pointed with coloured cement to match with colour of tile laid over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed. |
| 7 | M&L for plain cement concrete 1:2:4, type B0 using 12.50mm graded stone aggregate as in copings ,100mm thick,including weathering, slightly rounded or chamfered angles and throating including formwork complete all as specified and directed. |
| 8 | M&L for plain cement concrete 1:2:4, type B0 (using 12.50mm graded stone aggregate) as in seismic and other similar bands, plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed platescoping including weathering, slightly rounded or chamfered angles and throating including formwork complete all as specified and directed. |
| 9 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard/ dence soil. |
| 10 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth , not exceeding 10 sqm on plan for foundation ,for shafts, wells, cesspits, manholes, pier holes, laying CI/GI water tubing etc and getting out in any type of soil complete all as specified and as directed. |
| 11 | All as per item No 09 above but for depth exceeding 1.5 m and not exceeding 3.00 m |
| 12 | All as per item No 09 above but for depth exceeding 3.0 m and not exceeding 4.50 m |
| 13 | M&L for brickwork with fly ash old size bricks straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 complete all as specified and directed |
| 14 | M&L for rendering 15 mm thick on faces of brickwork in cement mortar 1:4, mixed with WPC @3% by weight of cement finished even and smoth without using extra cement complete all as specified and directed.Note:- WPC shall be measured and paid seperately under relevant item. |
| 15 | M&L for rendering 15 mm thick in cement mortar 1:4 on surfaces other than fair face of brick work , finished the surface even and smooth without using extra cement complete all as specified. |
| 16 | supply only water proofing compound |
| 17 | M&L for precast reinforced cement concrete 1:2:4 type B1 using 20mm graded stone aggregate set in cement mortar 1:6 as in cover slabs for drains,manholes etc and similar articles with plain face including necessary form work as required complete all as specified and directed.Note: Reinforcement shall be measured and paid separately under relevant item . |
| 18 | M&L for TMT bars 8mm dia and over, cut to length, bentto shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding withthe including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete |
| 19 | M&L for mild steel work as in clamps,steps, supports, hold fast ,wall piers, rungs, handles of manholes and other similar articles complete all as specified |
| 20 | M&L for extra for forming fair finished to drain or channels up to 30 cm inner girth in cement concrete using extra cement including necessary forms/moulds etc complete all as specified |
| 21 | M&L for DWCPE (SN8) 150mm bore ,confirming to IS-16098 , laid and jointed including testing with and including necessary jointing material tees /union /socket etc complete as specified and directed. |
| 22 | M&L for DWCPE (SN8) 200mm bore ,confirming to IS-16098 , laid and jointed including testing with and including necessary jointing material tees /union /socket etc complete as specified and directed. |
| 23 | M&L for DWCPE (SN8) 300mm bore ,confirming to IS-16098 , laid and jointed including testing with and including necessary jointing material tees /union /socket etc complete as specified and directed. |
| 24 | M&L for DWCPE (SN8) 400mm bore ,confirming to IS-16098 , laid and jointed including testing with and including necessary jointing material tees /union /socket etc complete as specified and directed. |
| 25 | M&L for concrete bed to drain pipes of 150mm dia with plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate ,including packing under and haunching against the sides of pipes after they are laid and tested after laying complete all as specified and directed. |
| 26 | M&L for concrete bed to drain pipes of 200mm dia with plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate ,including packing under and haunching against the sides of pipes after they are laid and tested after laying complete all as specified and directed. |
| 27 | M&L for concrete bed to drain pipes of 300mm dia with plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate ,including packing under and haunching against the sides of pipes after they are laid and tested after laying complete all as specified and directed. |
| 28 | M&L for concrete bed to drain pipes of 400mm dia with plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate ,including packing under and haunching against the sides of pipes after they are laid and tested after laying complete all as specified and directed. |
| 29 | M&L for shingle filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled, and blinded with earth and rammed including watering,ramming complete all as specified. |
| 30 | Returning, filling in in any type of soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed. |
| 31 | Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 32 | M&L for plain cement concrete 1:3:6 type C2 using 40mm graded stone aggregate,75mm thick as in plinth protection, finished the surfaces fair and even complete all as specified. |
| 33 | S&F PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to wall or floor complete all as specified and directed. |
| 34 | S&F PVC (SWR) bends 110mm dia of any radius with access door with rubber ring joints fixed to wall or floor complete all as specified |
| 35 | S&F 110mm dia PVC (SWR) branch piece, double (double Y) equal or unequal with rubber ring joints fixed to wall complete all as specified |
| 36 | S&F 110mm dia PVC (SWR) vent cowl with rubber ring joints fixed to wall all as specified |
| 37 | S&F PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints fixed to wall or floor complete all as specified and directed. |
| 38 | S&F PVC (SWR) bends 75mm dia of any radius with access door with rubber ring joints fixed to wall or floor complete all as specified |
| 39 | S&F 75mm dia PVC (SWR) junction double (double T) equal or unequal with rubber ring joints fixed to wall complete all as specified |
| 40 | S&F PVC (SWR) Gully trap of size 125 mm /110mm setting and jointing with solvent cement complete all as specified and directed |
| 41 | Demolition of cement concrete reinforced of any description in any position complete, all as specified and as directed. |
| 42 | Demolition and breaking up150 mm dia bore SGSW / RCC hume drain pipe including PCC packing under hunching against the sides of pipes including bed concrete complete all as specified and directed by Engineer-in-Charge |
| 43 | Demolition and breaking up 200 mm dia bore SGSW / RCC hume drain pipe including PCC packing under hunching against the sides of pipes including bed concrete complete all as specified and directed by Engineer-in-Charge |
| 44 | Demolition and breaking up 300 / 400 mm dia bore SGSW / RCC hume drain pipe including PCC packing under hunching against the sides of pipes including bed concrete complete all as specified and directed by Engineer-in-Charge |
| 45 | Demolition of stones or brick masonry or block walling, built in cement mortar including all quoins, arches etc., but excluding ashlar facing, dressed stone work etc.including removal of debris to a distance exc eeding 1.5 km but not exceeding 2 Km complete all as specified and as directed. |
| 46 | Dismantling PVC /CI drain pipes 75 to 110 mm dia, fixed to walls, laid in floors or in trenches or in any position including all fittings all as specified and directed. |
| 47 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided and removing the debris off complete all as specified and directed. |
| 48 | Demolition of reinforced cement concrete concrete of any description as in cover slab (other than ground floors), and similar suspended work complete all as specified and directed. |
| 49 | Taking down cement plaster on brick or stone walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed |
| 50 | M&L for brickwork with fly ash old size bricks straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and directed |
| 51 | M&L for brick work with old size fly ash bricks, straight or curved on plan to any radius as in half brick thick walls built in CM 1:4 complete all as specified and directed. |
| 52 | M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick work / concrete surfaces , finished even and fair complete all as specified and as directed. |
| 53 | M&L for preparation of new plastered or unplastered surfaces of walls with sand paper and make the surface smooth and applying two coats of cement base paint complete all as specified and directed. |
| 54 | M&L for plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as in surface channels including throating and use and waste of form work and finishing the exposed faces of concrete even and smooth without using extra cement complete all as specified and as directed |
| 55 | M&L for extra for forming fair finished channel not exceeding 55cm in girth in cement concrete using extra cement including forms moulds/ mitred/ stopped end, etc., complete all as specified and as directed |
| 56 | Taking up or down unserviceable HDPE 110 mm bore including all cleaning for re fixing complete all as specified and directed. |
| 57 | Taking up or down unserviceable HDPE 160 mm bore including all cleaning for re fixing complete all as specified and directed. |
| 58 | Relaying of HDPE tubing 110 mm bore with new fitting as required in trenches after cleaning complete all as specified and directed |
| 59 | Relaying of HDPE tubing 160 mm bore with new fitting as required in trenches after cleaning complete all as specified and directed |
| 60 | Supply and laying HDPE pipes 160/150 mm dia of 10 Kg /sqcm including neceaasry fusion welding for laying in trenches,specials and fittings as required at site including testing for water leakage complete all as specified and as directed. |
| 61 | Supply and laying HDPE pipes 110/100 mm dia of 10 Kg /sqcm including neceaasry fusion welding for laying in trenches,specials and fittings as required at site including testing for water leakage complete all as specified and as directed. |
| 62 | Supply and laying HDPE pipes 25 mm dia of 10 Kg /sqcm including neceaasry fusion welding for laying in trenches,specials and fittings as required at site including testing for water leakage complete all as specified and as directed. |
| 63 | S&F 25 mm bore gate / Ball valve (Flange end both side) complete all as specified and as directed. |
| 64 | Supply,install and testing of sewage submersible pump set of 5 HP capacity , Three phase , 1000 LPM at 10 metre head complete all as specified and as directed. |
| 65 | M&L for draining out or pumping out all sewage water from different STP Treated water tank of 70000 litres capacity ,having size of 5.0m x 4.7 m x 3.0 m, cleaning the internal surfaces of by scrapping down / brushing and removing all silt, dirt, algae etc from walls, floors, washing / cleaning with water and applying one coat of white wash to all internal surfaces of floor, walls and complete all as specified and directed. |
| 66 | Supply, laying and testing of XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) LT 1100 volt grade with stranded aluminium conductor of size 16 sqmm 4 core complete all as specified and directed. |
| 67 | M&L for sub class \\"B\\" brick laid dry flat (width equal to be length of the bricks) over sand cushioning along the length of cable complete all as specified and directed. |
| 68 | M&L for sand cushioning with a layer of fine sand 8 cm thick before laying the cable and 15 cm after laying the cable in trenches to cover under ground cable complete all as specified and directed. Note :-Punned down thickness of sand shall be considered for measurement |
| 69 | Supply, install, testing and commissioning of factory made Outdoor type dust and vermin proof(IP 54 protection) feeder Pillar LT Panel board cubicle double door hinged type of suitable size 415V AC, 50Hz, fabricated of GP/CRCA sheet 3.15mm thick machine pressed and angle iron frame 50mm X 50mm X 6mm grouted in PCC , powder coated in Seven Tank process inside and outside complete including 4 Pole aluminum Bus Bar of suitable size 100 Amp mounted on porcelain insulator ,concealed hinged door with Sliding door bolt door locking arrangement and enclosed in chamber made out of 2mm sheet thick GP/ CRCA sheet machine pressed and connection from incoming and outgoing electric cable with suitable size thimbles/lugs cable gland with open able shutters on both side and danger notice plate on all the four door comprising of following:-INCOMMING:-(a) Busbar 4 Pole, Aluminum, 100 Amps - 01 Set(b) MCCB 40 Amp 4 Pole, 16KA, of make Havells / Siemens/ Schneider ,with atdjustable thermal setting alongwith spreader terminals -01No.(c) LED type Phase indicator lamp(RYB) = 03 Nos(d) Ammeter Digital type, CT operated 0-100A range, MAKE: SECURE / L&T (with selector switch and CT 100/5 Amp) - 01 Set(e) Volt Meter Digital type 0-500 V range, Make: SECURE / L&T (With selector switch) - 01 SetOutgoing:- (a) DOLStarter 3 phase suitable for 5 HP sumbersible pump/ Non Clog Pump - 01 Nos(b) Single phase preventor of suitable rating -01 Nos. |
| 70 | M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts ,nuts, check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore (light grade) and watering pipe 20 mm bore GI pipe (light grade ) and PCC chamber with cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate and PCC 1:3:6 type C1 using 20mm graded stone aggregate , 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone aggregate , reinforced with 8 mm dia ,mild steel bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 5 of SSR PART I , with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switche, DBs) complete all as specified and testing on completion complete all as specified. |
| 71 | M&L for plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate for preparing stand post of size 20cm x20cm x40cm for water distribution point including necessary form work, exposed surface fair finished complete all as specified and as directed Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |