| 1 | Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and directed. |
| 2 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for foundation etc. and getting out in hard/ dense soil complete all as specified and directed. |
| 3 | M & L for PCC 1:4:8 type D-2 (Using 40 mm grade aggregate) in foundation, filling and mass concrete complete all as specified and directed. |
| 4 | M&L for brick work with sub class 'B' bricks built in CM 1:6 straight or curved on plan & exc 6 m mean radius with old size bricks complete all as specified and directed. |
| 5 | M & L for damp proof course (DPC) in cement concrete 1:2:4, type B-0 40mm, thick with using water proofing compound @ 3% by weight of cement including necessary formwork complete all as specified and directed. |
| 6 | Returning filling in , including, spreading, levelling, watering and well ramming in layers not exc 25cm in hard/dense soil complete all as specified and directed. |
| 7 | Removing excavated material (soil) to a distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and directed. |
| 8 | M & L for RCC (Nominal mix) 1:2:4, type B-1 using 20mm graded stone aggt) as in lintels over 1.50m clear span complete all as specified and directed. |
| 9 | M & L for form work to sides and soffits of floor or floor beams, lintels, shelves including supports, over hangs etc also splays between floor and beams etc in rough finished surfaces of concrete in flat complete all as specified and directed. |
| 10 | M & L for mild steel TMT bars 10mm dia and over cut to length bend to shape required including cranking bending spirally for column, hooking ends & binding with and including mild steel mild steel wire (ann ealed not less that 0.90 mm dia or securing with clip) complete all as specified and directed. |
| 11 | All as per sl item No 10 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed. |
| 12 | M&L for hardcore of broken stones gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 13 | M & L for 100 mm thick PCC 1:4:8 type D-2 (using 40mm graded stone agg) in sub base of floor complete all as specified and directed. |
| 14 | M & L for 75mm thick PCC 1:3:6 type C-2, (using 40mm graded stone agg) as in plinth protection, path/steps etc to be finished fair and even complete all as specified and directed. |
| 15 | M&L for PCC 1:3:6 type-C-2 using 40mm graded stone agg as in surface channels and drains including necessary form work complete all as specified and directed. |
| 16 | M & L for 15mm thick rendering on fair faces of brick work concrete surface in CM 1:6 finished even and fair complete all as specified and directed. |
| 17 | M & L for 15mm thick rendering on fair faces of brick work concrete surface in CM 1:4 mixed with water proofing compound finished even and fair complete all as specified and directed. (Note : Water proofing compound will be measured and paid separately) |
| 18 | M & L for three coats of white wash on newly plastered surfaces of walls including preparation of surfaces complete all as specified and directed. |
| 19 | M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. |
| 20 | Supply only integral water proofing compound |
| 21 | S&F Roof trusses (framed) trssed, purlin, crane gantries, rail and fastenings and heavey brackets framing (Beam, tee, angle, channels of flat sections) including distance pieces, cleates etc confirming to Fe 410W (Gde E-250 quality A) complete all as specified and directed. |
| 22 | S&F Pre-painted galvatume aluminum zince coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strenght of 550 Mpa as in roof covering /cladding to wall , fixed with self tapping screws complete all as specified and directed. |
| 23 | S&F for pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 24 | S & F steel ventilator with top hung shutter, including hinges, steel peg stay etc.complete all as specified and directed. |
| 25 | S & F 3.0 mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5Sqm in each pane complete all as specified and directed. |
| 26 | M & L for preparation of new or previously untreated steel and iron surfaces of any description, over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 27 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 28 | M & L glazed ceramic coloured tiles of size 300 x 450mm x 7mm thick on vertical surfaces such as in skirting, dados & risers to steps set & Jointed in neat cement slurry & pointed in colored cement to match fixed over and including 10 mm thick rendering in CM 1:4 complete all as specified and directed. |
| 29 | S&F 4 mm thick of size 600x600mm HSPC (high pressure Steam Cured) pre-primetered self embossed, textured designer board E-Board Classic to be fixed GI grid/section size 600mmx600mm with main runner 38x24x0.9mm thick ,cross tee 28.6x24x0.9 mm and wall angle 19x19x0.9 mm duly suspended with 2mm dia SS bar hangers 1200mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any size complete all as specified and directed. |
| 30 | S & F of Factory made single extruded WPC (Wood Polymer Composite) solid door/ window /Ceosetory windows & other Frames/Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 31 | S & F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.(Note: stainless steel butt hinges and necessary S S screws shall be paid separately as per specification. |
| 32 | S&F 125 mm stainless steel butt hinges and necessary SS screws complete all as specified and directed. |
| 33 | S & F 150 mm long Stainless Steel barrel tower bolts complete all as specified and directed. |
| 34 | S & F 125 mm long Stainless Steel handle complete all as specified and directed. |
| 35 | S & F Vitreous China squatting pan of pattern “long pan”, size 580 mm white with ‘P’ or ‘S” trap, front or back inlet and foot rests, any pattern (excluding flushing cistern and flush pipe) etc, complete all as specified and directed. |
| 36 | S&F PVC valveless, syphonic action type flushing cistern 10 ltrs capacity low level, with inlet, ball valve float, flush pipe and handle including brackets complete all as specified and directed. |
| 37 | S & F Vitreous china wash basin, white, flat back, size 550mm x 400mm including cutting for and pinning in ends of brackets and waste pipe complete all as specified and directed. |
| 38 | S&F 15mm dia Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed. |
| 39 | S&F for 600x450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 40 | S&F 15mm Brass CP wall mixer for mixing hot & cold water screwed down for iron pipe complete all as specified and directed. |
| 41 | S&F 15 mm bore bib taps cast copper alloy chromium plated fancy type screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 42 | S & F Stop/angle cock 15 mm bore cast copper fancy type chromium plated alloy screwed down high pressure with crutch or butter fly handle serwed both ends for iron pipe or for unions complete all as specified and directed. |
| 43 | S&F PVC connection 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed. |
| 44 | S&F brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed. |
| 45 | S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 46 | S&F brass chromium plated /SS Tubular towel rail, 20mm dia, D type, 60cm long between flanges and including Chromium plated brass screws and wooden /plastic cleats complete all as specified and directed. |
| 47 | S&F soap dish 160mm length of stainless steel fixed to wall complete all as specified and directed. |
| 48 | S&F 100 mm dia bore (sand cast pipe) cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed. |
| 49 | S&F 100 mm dia CI bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed. |
| 50 | S&F 75 mm dia bore (sand cast pipe) Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed. |
| 51 | S&F 75 mm dia CI bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed. |
| 52 | S&F 100 mm bore CI vent cowl complete all as specified and directed. |
| 53 | S&F 75 mm Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed. |
| 54 | M&L for PCC 1:4:8 type D-2 (Using 40mm graded stone agg) as in concrete bed to 100mm bore drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 55 | S & F 15mm bore medium grade galvanized iron pipe with all fittings & fixed complete to walls & ceiling or laid in floors complete all as specified and directed. |
| 56 | S & F 20mm bore medium grade galvanized iron pipe with all fittings & fixed complete to walls & ceiling or laid in floors complete all as specified and directed. |
| 57 | S&F Rotational moulded polythene water storage tank (cylindrical vertical with closed tops ) hoisted and fixed in position of 2000 Ltrs capacity including tank cover and all necessary connection of tank nipple complete all as specified and directed. |
| 58 | S&F PVC float valve, high pressure with polythene float and fly nut complete screwed for PVC pipe and fixed in 20mm bore pipe complete all as specified and directed. |
| 59 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in hard/dense soil complete all as specified and directed. |
| 60 | M & L for compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars , stiffeners , gusset plates, Fe-410- W(Gde E-250) quality B etc. complete all as specified and directed. |
| 61 | S&F Welded steel wire fabric (mesh) Weight N. exc 4 kg per square metre any size supplied and fixed complete to wood or steel members complete all as specified and directed. |
| 62 | Excavation over areas not exc. 1.50 m deep and getting out in hard/dense soil complete all as specified and directed. |
| 63 | M & L for PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in channels of man holes including necessary form work complete all as specified and directed. |
| 64 | M & L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in coping, haunching and the similar work weathering slightly rounded or chamfered edges and throating including formwork complete all as specified and directed. |
| 65 | S&F 150mm dia RCC pipes, class NP-2, laid in trenches or in floors and jointed with collars complete all as specified and directed. |
| 66 | M&L for PCC 1:3:6 type C-2 (using 40mm grade stone aggregate) as in bed to 150 mm dia drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 67 | M&L for brick work in cement mortar1:4 with sub class `B' bricks in one brick thick honey comb walling complete all as specified and directed. |
| 68 | M&L for brick work with sub class `B' bricks straight or curved on plan exceeding 6m mean radius with old size bricks built in cement mortar 1:4 as in pillars complete all as specified and directed. |
| 69 | M&L for brick work with sub class `B' bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed. |
| 70 | M & L for rendering in 15 mm thick in cement mortar 1:4, on fair faces of brick work, finished even and smooth without using extra cement complete all as specified and directed. |
| 71 | M & L for precast cement concrete (1:2:4) type B-1 using 20 mm stone aggregate as in manhole cover slabs round square or rectangular in shape and set in CM 1:4 complete all as specified and directed. |
| 72 | M&L RCC (nominal mix) 1:2:4, Type B-1, (using 20mm graded stone aggregate) as in slabs suported on wall complete all as specified and directed. |
| 73 | M & L form work to the soffits and side suspended slab n.exc 200mm thick for fair finished surface of concrete complete all as specifed and directed. |
| 74 | M & L for form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 5cm but n exc 10cm wide, finished rough finished surface complete all as specifed and directed. |
| 75 | M&L for loose filling with broken bricks aggregate of gauge 40 to 80mm in soakage pits, soakage wells complete all as specified and directed Please Enable Macros to View BoQ information |
| 76 | M&L for loose filling with broken bricks aggregate of gauge 40 to 80mm in soakage pits, soakage wells complete all as specified and directed Please Enable Macros to View BoQ information |