| 1 | Dry sinking of well true & vertical in all types of soil including sand, silt, clay, mixed up to 25% with gravel and river bed stones up to size 300 mm in any direction complete as per drawing and technical specification (depth from level of placing of cutting edge & internal dia, to be taken for measurement) rate includes all percentage of pebbles, boulders and river bed stones. (depth to be measured from ground level) for depth up to 5.00 m |
| 2 | for depth from 5.00 m to 10.0 mtr |
| 3 | for depth from 10.0 m to 15.0 mtr |
| 4 | for depth from 15.0 m to 20.0 mtr and above. |
| 5 | Wet sinking of well in all type of strata (soil & boulders in any quantity) including required operations like chiselling, air and water jetting, hoist drives, skilled divers etc. for removal of isolated obstructions and minor blasting if required and lifting of excavated material up to ground level, and spreading the same with ramming and watering within a radius of 50 m from the site of open well. Rate includes all percentage of pebbles, boulders and river bed stones. (depth to be measured from ground level) for depth up to 5.00m |
| 6 | for depth from 5.00m to 10.0 mtr |
| 7 | for depth from 10.00m to 15.0 mtr |
| 8 | for depth from 15.0 m to 20.0 mtr |
| 9 | for depth from 20.0 m to 25.0 mtr |
| 10 | for depth from 25.0 m to 30.0 mtr and above. |
| 11 | Earth work in excavation over areas (exceeding 30cm depth, 1.5 mtr in width and 10 SQM in plan) for construction of open well, lift up to 1.5 Mtr. including taking out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 meter.All kind of soil |
| 12 | Ordinary Rock |
| 13 | Hard Rock (Requiring blasting) |
| 14 | Hard Rock (Blasting Prohibited) |
| 15 | Add extra over item No. 2.39.1 for every additional lift of 1.5 Mtr. or part thereof : In all kind of soils. |
| 16 | Add extra over item No. 2.39.2-4 for every additional lift of 1.5 Mtr. or part thereof : In Ordinary rock and hard rock. |
| 17 | Add 20% extra over item No. 2.39 for excavation in saturated soil where pumping or baling out of water is required, including shoring strutting where required and dewatering. |
| 18 | Labour charges for horizontal boring 100 mm dia in open well in rocky strata with all types of rock cutting & drilling tools etc. including all T&P required for job including dewatering arrangement. |
| 19 | Providing & laying ISI marked GI Pipe Light duty ( “A” class) as per IS: 1239 for casing pipe for submersible cable external work 40 mm dia complete in all respect. |
| 20 | Supply & Installation of single phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.Up to 2.0 KW |
| 21 | Above 2.0 KW |
| 22 | Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. Up to 5.5 KW (7.5 HP) & head up to 120 mtr. |
| 23 | Up to 5.5 KW (7.5 HP) & head above 120 mtr. |
| 24 | 7.5 KW (10 HP) & head up to 120 mtr. |
| 25 | 7.5 KW (10 HP) & head above 120 mtr. |
| 26 | 9.3 KW (12.5 HP) & head up to 120 mtr. |
| 27 | 9.3 KW (12.5 HP) & head above 120 mtr. |
| 28 | 11 KW (15 HP) & head up to 120 mtr. |
| 29 | 11 KW (15 HP) & head above 120 mtr. |
| 30 | 13 KW (17.5 HP) & head up to 120 mtr. |
| 31 | 13 KW (17.5 HP) & head above 120 mtr. |
| 32 | 15 KW (20 HP) and above, head up to 120 mtr. |
| 33 | 15 KW (20 HP) and above, head above 120 mtr. |
| 34 | Supply and Fixing of Electric feeder panel (having projected canopy)for submersible pump set Single phase up to 5 HP, comprising of DOL Starter, MCB, Indicating Light, Ammeter, Volt meter, connection plate, condensers of approved make and the panel enclosure should be made out from 18 gauge M.S. Sheet with powder coating. Panel size Height 600 mm Width 500 mm depth 250 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The operation of panel should be suitable for on 240 Volt AC Supply. |
| 35 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB, DOL starter, overload relay, ampere meter, volt meter, phase preventer, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 300mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.Up to 5.00 HP |
| 36 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.Above 5 HP and up to 10 HP |
| 37 | Above 10 HP and up to 15 HP |
| 38 | Above 15 HP and up to 20 HP |
| 39 | Above 20 HP and up to 30 HP |
| 40 | Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. 3 core 4.0 Sq.mm |
| 41 | 3 core 6.0 Sq.mm |
| 42 | 3 core 10.0 Sq.mm |
| 43 | 3 core 16.0 Sq.mm |
| 44 | Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 10.0 Sq.mm, 4 core |
| 45 | 16.0 Sq.mm, 4 core |
| 46 | 25.0 Sq.mm, 3.5 core |
| 47 | 35.0 Sq.mm, 3.5 core |
| 48 | Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 49 | Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. |
| 50 | Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2\\" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug.125 mm dia |
| 51 | 150 mm dia |
| 52 | 200 mm dia |
| 53 | 250 mm dia |
| 54 | Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B\\" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.32 mm dia |
| 55 | 50 mm dia |
| 56 | 65 mm dia |
| 57 | 80mm dia |
| 58 | Providing & Lowering in tube well ISI marked HDPE pipe as per IS 4984:1995 or amended up to date in PE 80 grade and class PN 10 of following dia. including HDPE/GI fittings and PVC rope confirming to IS 5175:1992 or amended up to date, along with clamping of submersible cable etc. complete in all respect.40 mm dia |
| 59 | 50 mm dia |
| 60 | 63 mm dia |
| 61 | 75 mm dia |
| 62 | 90 mm dia |
| 63 | Providing, installation, testing and commissioning of submersible Monoblock pump set conforming to IS 8034 and 2 pole motor operating at synchronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fibre bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer's design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.2.2 KW (3.0 HP) |
| 64 | 3.7 KW (5.0 HP) |
| 65 | 5.5 KW (7.5 HP) |
| 66 | 7.5 KW (10 HP) |
| 67 | 9.3 KW (12.5 HP) |
| 68 | 11.0 KW (15 HP) |
| 69 | 15.0 KW (20.0 HP) |
| 70 | Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended up to date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia.50 mm dia |
| 71 | 65 mm dia |
| 72 | 80 mm dia Please Enable Macros to View BoQ information |