| 1 | Providing labour for cleaning, preparing plaster, and base for putty with brush of suitable type do all complete job as per direction of EI |
| 2 | Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand (zone-III): 4 graded stone aggregate 20 mm nominal size) |
| 4 | Dismantling R.C.C. work including - do- do- E/I. |
| 5 | Reinforceemnt cement concrete work in beams, suspended floors, roofs having slope up to 15º landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircase above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for Chajjas |
| 7 | Reinforceemnt cement concrete work in beams, suspended floors, roofs having slope up to 15º landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircase above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 9 | providing Tor steel reinforcement of 8, 10 mm and 12 mmmm dia bar as per approved design and drawing excluding carraige of M.S.bars to work site , cutting, bending, and binding with annealed wire with cost of wire removal of rust placing the rod in position all complete as per building specification and direction of E/I8mm dia |
| 10 | 10mm Dia |
| 11 | 12mm & 16 mm Dia |
| 12 | Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 13 | Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 14 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
| 15 | Providing 19mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 16 | Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 17 | S/F M.S. grill made of 20 x 6mm M.S. flat as per approved design and drawing, properly fabricated with joints continous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction ofE/I. (Where materials is not supplied by the deptt.) |
| 18 | Supplying fitting and fixing 20 gauge G.C.I. Sheet (Door & Window) gate on M.S.angle frame of size 60*60*6mm, including cost of fabrication providing necessary locking arrangements worth haskel and domny duly fixed in C.C. (1:2:4) blocks of required size, |
| 19 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 20 | Providing applying plaster of paris putty of 1mm thickness over plastered surface to prepare the surface even and smooth copmlete .-do-do- as per sp. And direction of E/I. |
| 21 | Providing two coat of oil bound distemper of approved shade and make over a primer coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding, washing floors and taxes all complete as per building specification and direction of E/I. |
| 22 | Finishing wall with textured exterior paint of required shade New work ( Two or more coats applied @ 3.28ltr/10sqm) over and including primer coat of exterior primer applied @ 2.2./10sqm |
| 23 | Finishing walls with Premium Acrylic Smooth exterior paint with of required shade: Old work(Two or more coats applied @ 1.67 ltr/ 10 sqm) on existing paint surface |
| 24 | Provinding primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurment Area shall be multiplied by the co-efficient as indicated in building specificaton.)Multiplying Factor-1.2 (for each side) as per Table -1 [IS:1200] |
| 25 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Multiplying Factor-1.0 (for painting all over) |
| 26 | Providing and laying double charge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer ) with water absorption less than 0.08% and confirming to IS 4457:2007 of approved make in all colours and shades laid on 20mm thick cement mortar 1:4 (1 cement : 4 course sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigment etc,complete.Size of tile 300x300x10mm |
| 27 | Providing and laying 25mm thick kotah stone slab flooring of approved size texure and colour over 19mm thick base of lime mortar (1:1:1) (limeputty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 28 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 MM |
| 29 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.110 mm bend |
| 30 | Shoe - 110 |
| 31 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.Clip 110mm |
| 32 | Providing 150mm wide brick drain in cement mortar (1:6) with as. 150mm clear depth and 250mm apron including cost of earthwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 33 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20mm nominal size ) over 75mm bad by dry brick ballast 40mm nominal size well rammend and consolidated and grouted with fine sand including finishing the top smooth. |
| 34 | Carriage of materialsCement |
| 35 | Steel |
| 36 | Stone chips |
| 37 | Bricks |
| 38 | Wiring for light /fan point / exhause fan point / call bell point with 1.5 sq.mm FRPVC inlsulated copper conductor single core cable in surface / recessede conduit with paino type switch phenolic laminated sheet suitable size M.S box insulated copper conductor.Group - A |
| 39 | Wiring for light /power pluge with 2x4sq.mm FRPVC insulated copper conductor single core cable in surface / recessede PVC conduit along 1 No Sqmm FRPVC insulated copper conductor single core cable for loop earthing as required. |
| 40 | Wiring for circuit/sub main wiring alongwith earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire |
| 41 | 2 x 4.0 sq.mm + 1 x 4.0 sq.mm earth wire |
| 42 | 2 x 6 sq.mm + 1 x 6 sq.mm earth wire |
| 43 | 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire |
| 44 | Supplying and fixing suitable sizes G.I/PVC box on surface or inrecess with phenolic laminated sheet cover in frong including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps paino type switch connection painting etc as required. |
| 45 | Supplying and fixing suitable size GI/PVC box of 121 mm x 173 mmx 48 mm /(6\\"x8\\") (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providng and fixing 6 pin 15/ amps paino type switch connection painting etc as required. |
| 46 | S/F following rating double pole 240 volts isolator in the existing MCB DB complete with connection testing and commissoning etc as required.40 amps |
| 47 | 63 amp DP |
| 48 | Providing and fixing following capacity DP/TP&N sheet metal/switchs disconnector fuse unit in existing metal board with rewireable type fuse including drilling holes in metal board making connection earthing the body etc as required.100 amp TP&N |
| 49 | Providing and fixing following capacity bubar, chabmer with 4 strips of suitable sizes made of copper, heavy duty complete with all accessories including connections earthing the body100 Amp busbar chamber |
| 50 | 200 Amp busbar chamber |
| 51 | S/F S.P MCB DB Supplying and fixing following way single pole netural sheet MCB distribution board 240 volts on surface / recess complete with tinned copper busbar netrual ibulsbar earth bar din bar detachable gland plate interconnections phosphatized and powder painted including earthing etc as required (But without MCB/RCCB/ Isolator)2 way single door (for campus light) |
| 52 | 6 way single door |
| 53 | 8 way single door |
| 54 | S/F 6 amp to 32 amp ratting 240 volts \\"B\\" series MCB suitable for lighting and other loads of the following poles in the existing MCB DB complete with connection testing and commissiong as per required. |
| 55 | S/F PVC/GI box fo following sizes on surface or in recess with suitable size of phenolic laminated sheet cover infront incliuding painting etc170 mm x 221 mm x 48 mm deep /(8\\"x10\\") for MCB |
| 56 | S/F 2 pin 5 amp celling rose on the existing junction box/wooden block including connection etc |
| 57 | Supplying and fixing batten / angle holder including connection etc as req. |
| 58 | S/F following paino type switch /socket on the existing switch box/ cover including connection etc as req.Electronic step fan regulator, deluxe |
| 59 | 15/16 Watt LED Bulb |
| 60 | S.I.T.C. of following rating recess/surface mounted LED round/ square shape down light luminarie with pressure die cast housing for single phase supply voltage. luminarie shall be confirmed to IS:10322 part-5/section-2 or IEC-62722 with all necessary accessories etc. complete as required18/20W LED Round Down light |
| 61 | Supply, installation, testing and Commissioning of following size fan 3 Blades confirming to IS:374:2019 including wiring the down rods of standard for 230V 50 Hz, single phase supply etc. complete as required1200mm(48'') Ceiling Fan |
| 62 | (a) 2 core 6 sq mm )for campus light, gate light, Toilet service connection) |
| 63 | S/F/F 4'x3' size of panel board made of commercial board mounted on MS angle frame including the cost of grouting the same on wall all complete as req. |
| 64 | Add 18% G.S.T |
| 65 | Add 1% L.C Please Enable Macros to View BoQ information |