| 1 | MRL28-Panbari Bodo gaon to Panbari PWD Road |
| 2 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201.By Manual Means |
| 3 | Compacting Original Ground :-- Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1.Flexible Pavement |
| 4 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. |
| 5 | Construction of embankment with approved material obtained from borrow pitswith a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 |
| 6 | Granular Sub-base with Well Graded Material (Table 400.1)By Mix in Place Method (Grading-I) Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. |
| 7 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. |
| 8 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. |
| 9 | Prime Coat Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 |
| 10 | Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503. |
| 11 | Mix Seal Surfacing Providing, layingand rollingof close-graded premix surfacing material of 20mm thickness composed of 11.2mm to 0.9mm(Type-A)or13.2mmto0.9mm(Type-B) aggregates using penetration grade bitumen to required line,grade and level to serve as wearing course on a previously prepared base, including mixing in a suitableplant, laying and rolling with a three wheel 8-10kNstatic roller and finishing to required level and grades as per Technical Specification Clause 509 |
| 12 | Kilometre stone Reinforced cement concrete M15 grade kilometre local stone of standard design asper IRC:8 fixing in position including painting and printing , etc as per drawing and technical specification clause 1703.ii) Km stone |
| 13 | Kilometre stone Reinforced cement concrete M15 grade kilometre local stone of standard design asper IRC:8 fixing in position including painting and printing , etc as per drawing and technical specification clause 1703.iii) 200 m stone |
| 14 | Providingandfixingofretro-reflectorised cautionary,mandatory and informatorysign as per IRC:67 made of encapsulated lens type reflective sheeting videClause 1701.2.3 fixed over aluminium sheeting, 1.5mm thick supported on amild steel angle iron post 75mmx75mmx6mm firmly fixed to the ground bymeans of properly designed foundation with M15 grade cement concrete 450mmx450mmx600mm, 600mm below ground level as per drawing sandTechnical Specification Clause 801600 mm equilateral & triangle |
| 15 | Providingandfixingofretro-reflectorised cautionary,mandatory and informatorysign as per IRC:67 made of encapsulated lens type reflective sheeting videClause 1701.2.3 fixed over aluminium sheeting, 1.5mm thick supported on amild steel angle iron post 75mmx75mmx6mm firmly fixed to the ground bymeans of properly designed foundation with M15 grade cement concrete 450mmx450mmx600mm, 600mm below ground level as per drawing sandTechnical Specification Clause 801600 mm circular |
| 16 | Providingandfixingofretro-reflectorised cautionary,mandatory and informatorysign as per IRC:67 made of encapsulated lens type reflective sheeting videClause 1701.2.3 fixed over aluminium sheeting, 1.5mm thick supported on amild steel angle iron post 75mmx75mmx6mm firmly fixed to the ground bymeans of properly designed foundation with M15 grade cement concrete 450mmx450mmx600mm, 600mm below ground level as per drawing sandTechnical Specification Clause 801 800 mm x 600 mm rectangular |
| 17 | Providing and fixing of typical Logo Board with PMGSY Logo as per MORD specifications and drawing. 1 nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 1 nos. steel plate will be welded horizontally with 1 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The 1 no steel plate will be welded vertically to 1 no. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
| 18 | Providing and fixing of typical Citizens Information Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick duly welded with 5mm thick steel plate on back on edgtheisc.k TMheS 4s hneoest. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
| 19 | Providing and fixing of typical Maintainance Information Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick duly welded with 5mm thick steel plate on back on edgtheisc.k TMheS 4s hneoest. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
| 20 | Title Informatory Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 4 nos. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
| 21 | Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. |
| 22 | Cross Drainage WorksBOX CULVERT - 1 x3M x3M Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. |
| 23 | Sand Filling in Foundation Trenches as per drawing and technical specification Clause 1108 |
| 24 | Providing PCC Grade M15 for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 |
| 25 | Providing Reinforced cement RCC GRADE M-25 concrete in box cell complete as per drawings and technical specification Clauses 802, 804,805, 806, 807, 1202 and 1204. |
| 26 | Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 (Graular Materials) |
| 27 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 |
| 28 | Construction of flexible apron1m thick comprising of loose stone boulders weighing not less then 25 kg beyond curtain wall |
| 29 | Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications a)TMT-IS1786(Fe-500D)PrimaryProducer (TATA/SAIL/EsserSteel/ Jindal panther steel/ Shyam steel or equivalent) |
| 30 | Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCCpost not to exceed1in 500, centre to centre spacing between vertical post not to exceed 2000mm, leaving adequate space between vertical posts for expansion, complete as per approved drawings and technical specifications. |
| 31 | Providing pressure relief pipes 100mm dia in bottom slab of box cell on a filtermedia base of 500mmx500mm as per drawing and technical specification Clause 1205.5.7 |
| 32 | Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications Please Enable Macros to View BoQ information |