| 1 | Supply and delivery of clear water vertical wet type submersible pump suitable for bore well conforming to IS : 8034 ( and as amended there after ) with standard MOC for potable clear cold water and BEE 3 star rated capable of discharging noted 33 M³/hr against head of 26 mtr water column. The pump shall be directly couprled with a continuous rated 2- pole suitable wet type vertical squirel cage induction motor conforming to IS : 9283 (and as amended thereafter),suitable for operation in AC Three phases 415 V,50HZ (category B motor). Test certificate along with characteristic curve should be submitted at the time of delivery.Make: Approve make of PHED. |
| 2 | Supply, delivery at site and storage of 1.1 KV Grade 3 Core 10 sq.mm Al. Ar. XLPE Cable. (Make: PHED Approved make) for 2 Nos. Submersible Pump. |
| 3 | Supply and delivery of 1.5 mtr long 80mm dia UPVC standard type column pipe [cream color] with both side threaded and one end side socketed with registered KPMG. |
| 4 | Supply delivery of 32mm dia PVC pipe of ASTMD 1785 schedule 80 for laying cable through riverbed. |
| 5 | Supply and delivery of 150 mm x 40 mm MS clamp made of 5 mm thick and 24 mm width strip with nuts & bolts for holding 32 mm dia pipe as per direction and as per requirement. |
| 6 | Supply delivery and installation of DOL starter controller of over load relay range: 6-10 Amp, contactor size-20Amp for operation submersible pumping machinery upto 5 HP with Ammeter, Voltmeter, Selectror switch, Push button as per direction of EIC.(Make-PHED Approved make ) |
| 7 | Fixing only starters (for motor control) on flat iron frame / angle iron frame on wall Direct on Line starter for motor. |
| 8 | Supply of Suitable kiox box for cable connection of submersible pump motor set with Degree of protection IP 65 including suitable legs and 3 Nos. Al. Bus bar for 32 Amps and all necessary earthing arrangement and insulator as per direction of EIC. |
| 9 | Making CC foundation for support of the kiosk box after excavating the earth upto a depth of 0.6 Mtr below the GL including supply of all materials complete with 12 mm thick cement plastering with net cement finishing complete as per direction of EIC (size: 3' x 1'x5') |
| 10 | Laying of 10 sq mm cable by cutting sand at riverbed and laying through GI pipe with MS clap & refitting as per direction of EIC. |
| 11 | Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. |
| 12 | Laying of two cables upto 35 sqmm in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed. |
| 13 | Installation of Submersible Pumping machinery to newly sunk tubewell along with column pipe (as requried), top cover, Valves, and Specials of above with protection pipe,and supply of MS clamp,nut bolt, cable gland, sockets etc. making interconnection of the pump delivery line to pump collecting main line (if required) near tubewell with supply of all necessary pipe, reducer/enlarger, GI/MS specials etc. including brick, sand, cement, rod etc and laying & drawing of all cable & cable protection pipe as required and all to complete the job including all connection & testing commissioning as per direction of EIC. |
| 14 | Excavation of soil for installation of Earth Electrode and filling & ramming For Morrum Soil. |
| 15 | Earthing with 50mm dia G.I pipe 3.64mm thick 3.04mtr long and 1 x 4 swg. G.I with (4mtrs long)13mm dia x 80mm long GI bolts, double nuts,double washers including supplying and fixing 15mm dia G.I pipe protection (1mtr long)to be fitted with bitumen and salt partly under the ground level and partly above the ground level driven to an average depth of 3.65mtr below the ground level and restoring the surface duly rammed.As per direction of EIC.By ISI- Medium GI Pipe |
| 16 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. |
| 17 | Extra for treatment of soil by using salt & charcoal or coke for plate electrode. |
| 18 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6 ) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. |
| 19 | Painting of any steel/ iron surface with no. of coats of paints as given below with ready mixed paint/primer of approved make and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint. i) 1st coat of synthetic enamel paint over the primer |
| 20 | 2nd coat of synthetic enamel paint over the 1st coat |
| 21 | Add GST @ 18% |
| 22 | Add CESS @ 1% Please Enable Macros to View BoQ information |