| 1 | Excavation in foundation and trenches ( For pipes and pits ) up to all depths in all classification of earth work such as pick work ,jumper work ,saturated soil including bailing or pumping out water ,blasting soft/hard rock or chiseling soft/hard rock where blasting is prohibited in all lifts including trimming & dressing of sides, leveling of beds to correct grade i/c shoring /strutting ,planking ,timbering & dewatering wherever required ,stacking the usable & unusable material /soil separately & after laying ,jointing & testing of pipes ,returning the useable soil in trenches in 15 cm ,layers including consolidating of such deposited layer by ramming & watering & then deposing of all surplus excavated soil / unusable material as directed with in all leads and lifts including restoration of unmetalled surfaces to its original condition and including cost of diversion for traffic , night signals ,fixing caution boards ,crossing over trenches for access to houses ,fencing etc. complete in all respects with in all lead and lifts as per direction & satisfaction of Engineer - in - charge. |
| 2 | Providing and laying cement concrete 1:6:12 (1Cement:6sand:12 graded stone aggregate 40mm nominal size) and curing complete excluding the cost of form work foundation and plinth with in all leads and lifts |
| 3 | Providing & laying cement conerete 1:5:10 (I cement 5 sand 10 graded stone agg 40mm nominal size) and curing complete excluding the cost of form work in foundation & plinth with in all leads and lifts |
| 4 | Providing and laying cement concrete 1:1.5:3 (1Cement: 1.5sand:3graded stone aggregate 20mm nominal size) & curing complete excluding cost of form work and rein-forcement for reinforced concrete work :- |
| 5 | In foundation and footing,bases of columns, and the like mass concrete. |
| 6 | in Suspended floors,roofs, landing ,shelves and their support balconies, beams, girders, bressumers & cantile-ver upto floor two levels. |
| 7 | Columns,pillars,post and struts,upto floor two level |
| 8 | Providing and laying cement concrete work 1:2:4 (1cement: 2 sand: 4 graded stone aggregate 20mm nominal size ) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in:- |
| 9 | Foundation,footing & bases of columns and the like mass concrete with in all leads and lifts complete in all respect. |
| 10 | Foundation and Plinth |
| 11 | Suspended floors, roofs, landings and shelves and their supports, balconies, beams ,griders bressumers and cantilevers upto all floor level. |
| 12 | Providing Tor steel reinforcement for RCC work including bending, binding & placing in position complete upto floor two level. |
| 13 | Providing and Fixing of pannel of size 1.80 x 1.20 mtr fixed in a pannel made of conduit pipe of 32 mm dia as per design i/c cutting welding to the wire mesh made of GI wire 3mm thick to the pannel complete in all respect. |
| 14 | Steel work welded in built up sections,trusses and framed work including cutting,hoisting, fixing in position and applying a priming coat of red lead paint :-in gratting,framed guard bar,ladders,railingbrackets and similar works. |
| 15 | Random rubble masonary / polygonal rubble masonary ( un coursed brought to courses) with hard stones of approved quality in foundation and plinth including levelling up with cement concrete 1:6:12( 1 cement : 6 sand : 12 graded stone aggregate 20 mm nomina size) at plinth level in cement mortar 1:6( 1 cement : 6 sand) within all leads and lifts complete in all respect. |
| 16 | Brick work using common burnt clay building bricks (IInd class) in super structure above plinth level upto floor two level in cement mortar 1:6 (1cement : 6 sand) with in all leads and lifts. |
| 17 | Brick work using common burnt clay building bricks in foundation and plinth in cement mortar 1:4( 1cement : 4 sand) 2nd class brick work with in all leads and lifts. |
| 18 | Providing and fixing pressed steel doors / windows frme manufacture from commercial mild steel sheet of 1.25mm thickness including hinges jamb, beed and if required angle threshold of mild steel angle of section 50x25mm or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechancial means adjustable lugs with split and approved steel primer ( Profile -A) complete in all respects with in all lead and lifts as per direction & satisfaction of Engineer - in - charge. |
| 19 | Providing and fixing wood paneled glazed or paneled and glazed shutters for doors, windows and clear story 40mm thick windows including bright finished black enameled iron with necessary screws with second class deodar wood 40mm thick in all leads and lifts. |
| 20 | Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm, so as to give a fair finish including centring, shuttering , strutting and propping etc. with wooden battens and ballies height of propping and centering below supporting floor to ceiling not exceeding 4meters and removal of the same for insitu reinforced concrete and plain. |
| 21 | Foundation,footing & bases of columns and the like mass concrete with in all leads and lifts complete in all respect. |
| 22 | Flat surfaces such as soffits of suspended floors, roofs, landings and the like floors upto 200mm in thickness complete in all respect with in all leads and lifts complete in all respect. |
| 23 | Vertical surfaces such as wall (any thick.) partitions & the like i/c attached pillasters,buttresses,plinth & string courses & the like. |
| 24 | Sides and soffits of beam,beam haunching,cantilever and bressumers and lintels not exceeding 1 mtr. In depth in all heights from floor complete in all respect with in all leads and lifts complete in all respect. |
| 25 | Half brick masonary in common brunt clay building bricks in cement mortar 1:3( 1 cement : 3 sand) Extra half brick masonary in super structure for above plinth level up to floor two level. |
| 26 | Pointing on brick work with cement mortar in 1:3( 1 cement : 3 sand) with in all leads and lifts complete in all respect. |
| 27 | Providing and laying brick tiles over mumty roof grouted with cement mortar 1:3( 1 cement :3sand) over a 12 mm layer of cement mortar 1:3( 1 cement : 3 sand) and finished neat over RCC slab ( sloped portion) with in all leads and lifts complete in all respect. |
| 28 | 6 mm cement plaster to ceiling in CM 1:3 (1Cement : 3 Sand) with in all leads and lifts complete in all respect. |
| 29 | 15mm cement plaster in single coat on rough side of bricks/concrete /stone walls for interior plastering up to floor two level including arrises, internal rounded angles chamfers and / or rounded angles not exceeting 80 mm in girth and finished even and smooth complete in all respect including all leads and lifts cement mortar 1:6 (1 Cement : 6 Sand) |
| 30 | 20mm cement plaster in single coat of rough sides of bricks/concrete stone walls for interior plastering upto floor two level including arrises internal rounded angles chamber and rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:6(1cement:6sand) with in all leads and lifts. |
| 31 | Providing and fixing Ms grills of required pattern in wooden frames of windows etc with MS flants square or round bars with rounded headed bolts and nuts or by screws complete in all respect within all leads and lifts |
| 32 | Prov. & fixing wire gauge shutters using galvanized MS wire gauge of IS gauge designation 85 G. with wire of dia. 0.56 mm for doors,windows & clerestrey windows including bright finished black enameled iron hinges with necessary screws 30mm thick of 2nd class deodar wood with in all leads and lifts complete in all respect. |
| 33 | Stone boulder filling under floors / behind retaining wall under floor with in all leads and lifts complete in all respect. |
| 34 | Providing plinth protection 50 mm thick in cement concret 1:3:6 (1cement :3 sand: 6 graded stone aggregate 20mm nominal size) including finishing of the top surface of concrete smooth in all leads and lifts. |
| 35 | Constructing course rubble hammer dressed U shape open surface drain with side wall 15x22 cm in cement mortar 1:6 ( 1 cement : 6 sand) and in side plastering with cement plaster 1:3( 1 cement : 3 sand) including earth work and laying 10 cm cement concrete in 1:5:10 ( 1 cement : 5 sand : 10 graded stone agg. 40 mm nominal size) and 7.5 cm cement concrete 1:2:4 20 mm nominal size) and finished with a floating coat of neat cement complete as standard design with in all leads and lifts complete in all respect. |
| 36 | Providing 40x3mm flat iron hold fast 40cm long including fixing to frame with 10mm dial meters bolts and nuts and wooden plug and embeding in cement mortar block 30x10x15cm (1:3:6(1cement:3sand:6 graded stone aggregate 20mm nominal size with in all leads and lifts complete in all respect. |
| 37 | Providing and fixing M.S.fan clamp(Type-I of 16mm dial M.S. Bar bent to shape with hooked ends in RCC. Slab during laying including painting the exposed portion of loop all as per standard design complete. |
| 38 | White washing with lime on undecorated walls surface (two coats) to give an even shade including thoroughly brooming the surface dirt dust mortar dirt and other foreign matter in all leads and lifts. |
| 39 | Distempering with dry distemper of approved brand and manufacture ( Two coats ) and of required shade on undacorated wall surface to give an even shade over and including primer coat of whithing after throughly brushing the surface free from mortar dropping and other foreign matter including preparing the surface evenand sand papered smooth within all leads and lifts complete in all respect. |
| 40 | Finishing wall with water proofing cement paint of approved brand & manufacture & of required shade on undecorated wall surfaces ( two coats) to give an even shade after thotoughly brushing the surface to remove all dirt & remains of loose powdered materials. |
| 41 | Applying priming coat over new steel and other metel surfaces after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter sand paparing and knotting( Ready mixed paint bruhing red lead,red oxide). |
| 42 | Painting two coats(excluding priming coat) on new steel and other metel surfaces, with ready mixed paint brushing to give an even shade including cleaning of alldirt and dust and other foreign matter sand papering and stopping. |
| 43 | Providing and fixing anodized aluminium fittings of anodized transparent and shade with necessary screw etc.complete Sliding door bolt (250 x 16 mm ) |
| 44 | Providing and fixing anodized aluminium fittings of anodized transparent and shade with necessary screw etc.complete Tower bolt (200 x 10 mm ) |
| 45 | Providing and fixing anodized aluminium fittings of anodized transparent and shade with necessary screw etc.complete Handle (100 mm ) |
| 46 | Painting two coats (excluding priming coat) on new wood and wood based surface with ready mixed paint brushing the give and even shade including cleaning of all dirt dust and other foreign matter and sand papering and stopping with ready mixed paint other than white in all leads and lifts. |
| 47 | Terrazzo tile flooring present terrazzo tiles 20 mm thick with marble chips of specified sizes laid in floors treads of steps and landings on a bed of 25 mm average thickness of cement mortar 1:6( 1 cement : 6 sand) jointed with neat cement slurry mixed with pigment to match the shade of tiles ( wherever required) including rubbing and polishing complete with tiles of following shades within all leads and lifts complete in all respect. |
| 48 | Construction of Precast Toilet 1.00X1.00 mtr. Size of standard height and depth made of RCC planks frame and shutter of angle iron and plain CGI sheet WC Indian type and pit including excavation of toilet foundation and soak pit all kinds of soil and disposal of surplus excavated earth, filling with course sand, cement concrete flooring 1:2:4 ( 1 cement:2 sand: 4 graded stone aggregate 20mm nominal size) for rural sanitation system in all leads and lifts as per standard design and drawing or as per the direction of Engineer-in-charge. |
| 49 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-inCharge. |
| 50 | 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern |
| 51 | Wire Crate made of GI Wire filled with boulders with square cut falls against the wire (Wire Crate to be measured and paid for seperately) |
| 52 | Wire crates of G.I wire filled with bolders with squarecut faces against the wire (Bolder filling to be measured and paid for separately) G.I wire 5mm thick corresponding to SWG-6 (15cm x15cm mesh.) |
| 53 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete |
| 54 | Wiring for light point/exhaust fan point/callbell point with 1.50 sqmt PVC insulated PVC sheathed copper conductor cable in surface/recessed PVC conduit as required. |
| 55 | Wiring for light/power plug wiring with 1x4 sqmt PVC insulated copper conductor single core cable in surface/recessed PVC conduit along with 2x2.24 mm Dia.bore copper wire for loop earthing as required. |
| 56 | 2 x1.50 |
| 57 | 2 x2.50 |
| 58 | Supplying and fixing metal box of 80 mmx 100 mm x50 mm deep(normal size) on surface or in recessed with suitble size pharolic laminated sheet cover in the front including P/F. 3 pin 16/16 ampere socket outlet and 15/16 amp.Tumbler /piano type switch connection,painting as required(For power plug) |
| 59 | Supplying and fixing of 8 way single pole and neutral sheet steel MCB distribution board 240 volts on surface/recessed complete with tinned copper bush neutral link earth bar bin bar,detachable grand plate ,inter connections including painting,earthingetc. as required. |
| 60 | Supplying and fixing 5 Amps., 32 Amps,to rating 240 volts G series miniture circuit breaker of 32 Amp. 240 volts L-series miniture circuit breaker of 32 Amps. Single pole in the existing MCBDB complete with connection, testing and commissioning etc. as required Category-B |
| 61 | Supplying and fixing 5 Amps., 32 Amps 240 volts L-series miniture circuit breaker of single pole and neutral in the existing MCBDB complete with connection ,testing and commisioning etc. as reqd. category-B |
| 62 | Supplying and fixing 40 Amp. Double pole 240 volts insulator in the existing MCBDB complete with connections ,testing and commisioning etc. as required. |
| 63 | Supplying and fixing 40 Amp. Double pole 240/415 volts EL+MCB combination unit having a sensitivity current upto upto 300 milli amperes .In the existing MCBDB complete with connections ,testing and commisioning etc. as required. |
| 64 | Earthing with GI earth pipe 4.5 mtrs x 40 mm dia.including accessories and providing masonary enclousure with cover plate having locking arrangement and waitering pipe etc. (but without charcoal or coke and salt)complete as required) |
| 65 | Extra for using salt and charcoal for pipe earth electrodes as required. |
| 66 | Supplying and laying 6-SWG G.I. wire at 0.50 mtrs below ground level for conductor with earth electrode including soldering etc. as required. |
| 67 | Providing fixing testing and comissioning of ceiling fan 1200 mm(category - A ) and regulator including wiring of the down rod of standard length (up to 30 cm) with 1.5 sqmm PVC insulated copper conductor single core cable etc. as required complete in all respects as per direction and satisfaction of engineer in charge complete in all respects. |
| 68 | Providing and fixing LED Fluorescent box type (Monochromatic Light) 24 watt Philips/ Havells/ Bajaj/ Eveready/ Ujala/Luminous or any other ISI company make complete in all respect as per entire satisfaction of Engineer in charge. |
| 69 | Providing and fixing LED street lights 40 watt 110-220 V with complete fixtures including cost of providing and commissioning of electric wire as per required length ISI approved, Flexible pipe to cover the electric wire Havells/L&T/Philips/Syska make and making connection to existing electric syestem as per entire satisfaction of Engineer in charge. |
| 70 | Providing and fixing holder for bulbs Anchor/Havells/Syska make complete in all respect as per entire satisfaction of Engineer in charge. |
| 71 | Providing installation and commissioning and testing of of LED bulbs 20 watts fittings including 90 degree GI bend choke reflector of Havell/Bajaj /crompton /Greaves make complete in all respects within all leads and lifts as per direction and satisfaction of engineer in charge. |
| 72 | Providing and fixing round electrical holder sheet complete in all respect as per entire satisfaction of Engineer in charge. |
| 73 | Construction of RCC OHSR, 36000 ltr. Cap. With 3.00 mtr stagging height from ground level to bottom of dome slab comprising of inlet, Scour and over flow pipes as per details given below ground level to top dome of tank including GI bends of required degree, valve of reqiured size confirming to relevants code MS stair case i/c Mild steel flat railing around the container as well as around the complete stair case from bottom to top as per IS-specification, steel ladeer inner and outer side with required dia metre of MS flat of usual height as per site requirment. SFRC manhole cover of 500 mm dia and weight of frame and cover should not be less than 45 kg. ventilator at top dome with minimum opening of 45x450cms water level indicator including floats and measuring gauge lightening conductor with complete earthing arrangment etc. The RCC over head reservoir shall include randering/plastering of the uneven exposed surfact two coats of snowcem paint and any other component required for the completion of the job to the enitre satisfaction of Engineer-in-Charge. The offers shall also include details structural drawing design based on ebaring capacity of soil of propsed site and same shall be approved from the competent authority desigtn clacuation expension joints as required at site. The offer shall also include the cost of providing and fixing of GMS/MS pipes, duly flanged and sluice valve of required dia metre fitting complete including duck foot bends, puddle collers, expansion joints etc. comecting with rising main and distrubtion main with reqiured legnth from the edge of foundation and any other component required for the completiion of job upto the entire satisfaction of Engineer-in- Charge.Dia of pipe arrangementInlet pipe - 100 mm diaOutlet pipe - 100 mm diaScour pipe -100 mm dia Please Enable Macros to View BoQ information |