| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | All kinds of soil. |
| 3 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 5 | 1:2:4 (1 cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | 1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 7 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of Stone Aggregate 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 9 | 1:1.5:3(1 cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 10 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: |
| 11 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 13 | Foundations, footings, bases of columns, etc. for mass concrete |
| 14 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 15 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 16 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 17 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 18 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 19 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 20 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 21 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 22 | Electric resistance or induction butt welded tubes |
| 23 | Providing and fixing bolts including nuts and washers complete. |
| 24 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. |
| 25 | 80x0.90 mm M.S. laths with 0.90 mm thick top cover |
| 26 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 27 | 40 mm thick with 20 mm nominal size stone aggregate |
| 28 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 29 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 30 | Ridges plain (500- 600mm) |
| 31 | 12 mm cement plaster of mix: |
| 32 | 1:4(1 cement: 4 fine sand) |
| 33 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: |
| 34 | Two or more coats on new work |
| 35 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 36 | Two or more coats on new work |
| 37 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 38 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 39 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 40 | Two coats |
| 41 | Providing and laying hollow cement concrete block walling 200mm thick consisting hollow block of size 400 x 200x200mm of mix 1:3:6(1cement :3 coarse sand:6 graded stone agg. 10mm nominal down size) having a crushing strength of 3.5N/mm2 at 28 days as per I.S. 2185 (Part-I) 1979 laid in cement mortar 1:6(1cement : 6 coarse sand). |
| 42 | Upto floor five level |
| 43 | Extra for providing and fixing wind ties of 40x 6mm flat aluminium section. |
| 44 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work |
| 45 | 100 mm dia nominal bore |
| 46 | Providing and fixing PVC Green Hose pipe (Suction line) on surface including connecting with existing G.I pipe/ Foot valve with all accessories etc as per the direction of Engineer-in-charge. |
| 47 | 100mm dia PVC Green Hose pipes |
| 48 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 49 | 100 mm nominal bore |
| 50 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality: |
| 51 | 100 mm diameter pipe |
| 52 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work): |
| 53 | 100 mm nominal bore |
| 54 | Supplying at site : |
| 55 | R.C.C. Standards post/ struts/rails/ pales of mix 1:1.5:3 (1 cement : 1.5 coarsesand : 3 graded stone aggregate 12.5 mm nominal size) with wooden plugs or 6 mm bar nibs wherever required as per direction of Engineer-in- charge (cost of earth works in excavation, concrete works in foundation to be paid separately). |
| 56 | Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) :- Payment to be made per metre cost of total length of barbed wire used. |
| 57 | With G.I. barbed wire |
| 58 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. |
| 59 | G.I. pipes |
| 60 | Providing and fixing gun metal non- return valve of approved quality (flange end): |
| 61 | 100 mm nominal boreHorizontal |
| 62 | SITC of pump set with water cooled diesel engine equivalent to Kirloskar make 4R1040, 52 HP, with suitable RPM coupled with water pump equivalent to Kirloskar make, model DSM 80/36 with std C.I impeller having suction and delivery of 100mm x 80 mm with a minimum discharge of 110 cum/hr at a head of 80 mtrs including base frame with foundation bolts and nuts, coupling assembly, C.I foot valve 100 mm etc, fuel tank assembly with bracket of minimum 150 litres capacity, 1X12 Volts 180 AH battery (Exide/ SF) with cables and stand, silencer pipe, part catalogue, SFC environment friendly certificate, standard tools etc as & required. Please Enable Macros to View BoQ information |