| 1 | Procurement of materials including GST@18% i.e. for T.I.No 1 to 19: Heavy duty rewireable Switch Fuse Units with fuse base and carrier, shall comply with and be tested to the latest IS: 10027-2000 and IS/IEC60947-3 marked with standard ISI certification mark 100A Switch Fuse Unit TPN |
| 2 | 4 inch round Projection type Ammeter (range 0 50/100 Amps), MIAC Accuracy within 1.5 % and conforming to IS 1248/1968 |
| 3 | 4 inch round Projection type Voltmeter (range 0 -500 Volts), MIAC, Accuracy within 1.5 % and conforming to IS 1248/1968 |
| 4 | 150 mm Dia (NB) GI 90 degree bend as per IS-1239(Part-II)/1992 with latest amendments, both end welded with flange as per IS 6392/1971, table-17 with latest amendments, 50 mm Dia (NB) socket to be used as per IS-1239(Part-II)/1992 with latest amendments for priming, 50 mm Dia (NB) plug to be used in socket is as per IS-1239(Part-II)/1992 with latest amendments. Both bend and flange are duly ISI certification marked . (As per Annexure H ) |
| 5 | 150 mm dia 90 deg short bend |
| 6 | 150 mm dia long bend (with priming) |
| 7 | 150 mm Dia sluice valve with hand wheel, ISI marked IS:14846 |
| 8 | MS Surge tank as per drawing (Annexure-H) thr body of which made of 3mm thick MS sheet and top and bottom cover are made of 5 mm MS sheet welded with the body and strenghthen with rib etc. All joint must be electrically welded to a leak-proof condition and joint must be capable of withstanding pressure of 50 PSI. The Surge tank should be fitted with all accessories as specified in the drawing. Entire Surge Tank is to be painted both inside and outside over a coat of priming. |
| 9 | 80 mm dia M.S. Surge pipe of 3 mtr. Long made of 80 mm N.B. ERW pipe conforming to IS:1234(Pt-1) 2004, medium quality one end 80 mm flange welded of 10 mm thickness conforming to IS:6392/71, Table-17 |
| 10 | 150 mm dia MS special type Z bend from MS ERW pipe both end flanged welded pipes as per IS:1239 and flanges IS:6392/71, Table-17 |
| 11 | 150 mm dia Alfa-Alfa Valve (c Type), ISI marked IS:14846 with GM Bush |
| 12 | Supplying of UPVC pipes (class-I) IS: 4985/2000 certification marked with latest amendments lvorycoloured end plane, along with one matching coupler / socket (class-II ) duly IS: 10124/ 1988 marked and required solvent cement duly IS: 14182/1994 marked for each pipe. Length of eatch straight pipes 6 meters with tolerance (+) 10 mm upto the destination point inclusive of all charges. |
| 13 | 200 mm dia (class-I) nomial thikness 2.9 mm to 3.4 mm |
| 14 | 160 mm dia (class-II) nomial thikness 2.3 mm to 2.8 mm |
| 15 | Supplying of UPVC coupler (class-I/II) IS: 10124 ( part I&II) / 1988 with latest amendments upto the destination point inclusive of all charges. |
| 16 | 200 mm dia (class-II) |
| 17 | 160 mm dia (class-II) |
| 18 | Supplying of UPVC equal Tee ( Class-II) IS:10124 (part-5)/ 1988 with latest amendments upto the destination point inclusive of all charges. |
| 19 | 200 mm dia (class-II) |
| 20 | Supplying of UPVC bend (class-II) IS: 10124 (part-8) / 1988 with latest amentsupto the destination point inclusive of all charges. |
| 21 | 200 mm dia 60 deg bend |
| 22 | 200 mm dia 90 deg bend |
| 23 | Supplying for reducer comprising of two straight reducer IS: 10124 (part-8) / 1988 with latest amendments upto the destination point inclusive of all charges. |
| 24 | 200mm x160 mm dia UPVC reducer |
| 25 | Supplying FTP as per IS: 10124 (part-8) / 1988 with latest amendments upto the destination point inclusive of all charges. |
| 26 | 160 mm dia (class-II) |
| 27 | Supplying 150 mm dia MS Flange (12 mm thick) as per IS 6392/ 1971 with latest amendments upto the destination point inclusive of all charges.150 mm dia |
| 28 | 200 mm dia PVC end cap ISI Marked -IS10124 |
| 29 | Supply of solvent cement (havy bodied) |
| 30 | Supply of 150 mm dia rubber insertion 5 mm thick with proper reinforcemet two ply conforming to IS: 638/79 with ISI marked with latest Amdt. Suitable for raised surface of MS flange as IS: 6392/71 ( Table-511 & 17) |
| 31 | RENOVATION OF WTA Supply of approved quality pea shaped gravel of 2 mm to 4 mm size and gravel treatment of Tube well including screening washing cleaning etc. of the gravels at site complete as per direction of Engineer-In-Charge.For site at any district of West Bengal upto 180 KM distance from quarry. (Considering quarry at Durgapur) |
| 32 | Dismantling the existing G.I./ M.S. Delivery Pipe line connection between the existing D.C. Surge Tank/ Tripod Set & Tube Well assembly viz Sluice valve, Bend, Surge Tank/ Distribution Chamber / Tripod Set Connection pipe etc.and disconnection of delivery side viz. Special bend etc. all complete as per direction of the E.I.C. and stacking all serviceable materials at site. |
| 33 | Supplying, fitting & fixing of M.S. plate of size 40 cm x 40 cm, thickness 6 mm, consisting of two equal halves (40 cm x 20 cm), placed over Housing Pipe of HDTW/ MDTW to rest the supporting clamps, with semi circular hole of 170 mm dia. at centre including locking arrangement between the two halves on both sides, including fitting, fixing of 40 mm dia. G.I. bend by making a hole on plate for passing submersible cable smoothly and complete in all respect |
| 34 | Patch/Doubling Works Complete with 5mm MS plate including welding,gas cutting fitting and fixing complete. |
| 35 | Gas cutting to required size upto 8 mm thick M.S. plate, M.S. channel, angle etc. including labour charges, hire charges for all tools and plant |
| 36 | Electric welding charges upto 8 mm M.S. plate, M.S. channel etc. and other member of the barge including hiring charges of all tools and plants. |
| 37 | Installation / Erection of Surge Tank / Shore manifold (to be supplied from Deptt. free of cost) over a rigid base of Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) of Pakur variety of 1250 mm X 1250 mm X 150 mm. over a single layer of brick flat soling and embedding the legs of the surge tank/shore manifold within the concrete base including cost of all materials and labour and as per direction of Engineer-in-Charge. |
| 38 | Labour charges for fitting. fixing M.S. Special bend with 160 mm X 200 mm. dia. P.V.C. reducer with the help of flanged tail-piece by joining P.V.C. end of tail-piece and 160 mm. end of reducer with coupler and flanged end of tailpiece and special bend with rubber insertion, nuts and bolts complete. |
| 39 | Earth work in excavation of field trenches as per design section and alignment for laying of pipe lines (PVC, RCC, ACP etc.) upto a depth of 1500 mm all sorts of soils including removing, spreading or stacking extra earth as directed The item includes necessary trimming of sides trenches, levelling, dressing and ramming the bottom as required complete. |
| 40 | Labour charge for replacement of different PVC. Accessories in different portion of PVC. Pipeline of HDTW/ MDTW / RLI including taking out of the existing damage accessories, and excluding the supplying the new accessories of 4 Kg./cm2 capacity and as per I.S. specification at site and fitting,fixing the same by joining with solvent cement (cost inclusive) after roughening up the surface with wire brush, emery papers etc., to make the joint leak proof all complete as per direction of Engineer-in-Charge. |
| 41 | 160 mm X 140mm. PVC. Reducer |
| 42 | 140 mm. dia. 90°/60° & 45° long bend |
| 43 | 160 mm. dia. flanged tail piece fitted with Alfa-Alfa valve |
| 44 | Laying of P.V.C. pipes of different diameters within field trenches in curve / straight line using P.V.C. fittings, viz. Bend, Tee, Reducer etc. and making leak-proof joints with couplers after roughening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipes, fittings and solvent cement to be supplied by Deptt.) all complete as per direction of Engineer-in-Charge. |
| 45 | 200 mm dia PVC pipe. |
| 46 | Earth work in filling in trenches after laying pipe lines (PVC, RCC, ACP etc.) with good earth obtained from excavation of field trenches in layers not exceeding 225 mm, including watering and ramming etc. layer by layer complete. (Payment will be made on the basis of measurement of finished quantity of work.) |
| 47 | Fitting and fixing of M.S. / G.I. / C.l.accessories and special in pipe line (accessories & special to be supplied departmentally) including supply of jointing materials viz.rubber insertion, nuts & bolts, havoc Zink (Zink Oxide) complete as per direction of Engineer-in-Charge. |
| 48 | 150 mm. dia. C.I. sluice valve. |
| 49 | 80 mm. dia 3 metres long G.1.pipe with one end flanged |
| 50 | Labour Charges for fitting, fixing and laying, where necessary of following M.S/ G.I. / E.R.W. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge. |
| 51 | 150 mm. dia. ERW pipe. |
| 52 | 150 mm. dia. special bend, both ends flanged. |
| 53 | 150 mm. dia. 525 mm. long ERW pipe short piece, one end to be flanged and welded. |
| 54 | Supplying, fitting & fixing bolts with nuts & washers |
| 55 | Labour charges for fitting, fixing 150 mm. Dia. Alfa-Alfa valve with 160 mm. dia.P.V.C. riser pipe with the help of flanged P.V.C. tail-piece by joining the P.V.C. End of Tail-piece and riser pipe with coupler and flanged end of Tail-piece and Alfa-Alfa valve with rubber insertion, nuts and bolts etc. complete. |
| 56 | Labour charges for fitting, fixing 160mm. dia. P.V.C. riser pipe with 150 mm. dia. M.S. 90° bend by using P.V.C. tail piece. |
| 57 | Taking out the condemmed 150 mm dia. N.T.P./ T.P/ Alfa-Alfa valve from 150 mm dia. M.S./G.I. pipe of existing spout chamber by careful chiseling with least disburbance to the existing system of structure upto required limit and fitting, fixing of new one with 150 mm dia. M.S./G.I. pipe in proper position of the Each spout chamber using havoc zinc jute so as to make the joint leak proof including mending good all damages and returning back the condemned materials at store as per direction of Engineer-in-Charge. |
| 58 | Testing of pipe line system against leakage by filling the D.C. with water and supplying water through the entire pipe line network for at least 4 (four ) hours including hiring and transport of suitable generator, pump, tools & plants, fuel & lubricants, installation of the pump, connecting the same with pipe line network, making necessary electrical connection and dimantling all these after completion of test- all complete as per direction. |
| 59 | Dismantling all types of masonry exception cement concrete plane or reinforced, stacking servicable materials at site and removing rubbish as directed within a lead of 75 mtrs in ground floor including roof. (a) In ground floor including roof. |
| 60 | Dismantling all types of plain cement concrete works, stacking servicable materials at site and removing rubbish as directed within a lead of 75 mtrs in ground floor including roof. Add per extra additional floor over the rate of ground floor @ Rs.18.00 per Cum.(a)Upto 150mm thick. |
| 61 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. |
| 62 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm. |
| 63 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a) With earth obtained from excavation of foundation. |
| 64 | Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. |
| 65 | Hire and labour charges for shuttering with centering and necessary staging upto 4m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs,beams and columns, lintels curved or straight including fitting,fixing and striking out after completion of works(upto roof of ground floor) (a)25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In- Charge. |
| 66 | Ordinary Cement Concrete (mix 1:2:4) with graded stone chips (20 mm. nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevent IS codes.(i) Pakur Variety |
| 67 | Ordinary Cement Concrete (mix 1:1.5:3) with graded stone chips (20 mm. nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevent IS codes.(i) Pakur Variety |
| 68 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawingand direction.(a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor Steel / Mild Steel. (II) JSW/ JSPL/SHYAM/ SRMB/ BMASL/ELECRO STEEL/ SSL. |
| 69 | Brickwork with 1st class bricks in cement morter (1:6) b ) In foundation and plinth |
| 70 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. |
| 71 | Ordinary Cement Concrete (mix 1:2:4) with graded stone chips (20 mm. nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevent IS codes.(i) Pakur Variety |
| 72 | ASF stone in floor ,dado,staircase etc. with cement concrete (4:2:1) with stone chips laid in panels as directed with topping made with ordinary white cement (as necessary) and marble dust (1:2) including smooth finishing and rounding off corners including racking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/ sqm. Including all materials and labour 25 mm th. |
| 73 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding / staging where necessary(Ground floor) [Excluding cost of chipping over concrete surface] |
| 74 | With (1:6) cement mortar (b)20 mm thick plaster. |
| 75 | With 1:6 cement mortar. 15 mm thick |
| 76 | With 1:4 cement mortar. 10 mm thick |
| 77 | Neat cement punning about 1.5mm thick in wall, dedo, floor drain, door & window sill etc. complete. |
| 78 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality includig smoothening surfaces by sand papering etc. (This item is applicable to new work or old work when the original surface has been exposed by removal of old paint) |
| 79 | Painting with best quality synthetic enamel paint of approved make & brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface if necessary. On steel or other metal surface :With super gloss (hi-gloss) - Two coats with any shade except white |
| 80 | Dry Distempering to interior walls or ceiling including cleaning, washing, smoothing surface. (b) Two coats. |
| 81 | Applying decorative cement based paint of approved quality afte preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification.[Vide page no.197, item no-15(iii) of PWD Schedule]In Ground floor:(iii) Two coats. |
| 82 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 83 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a) On timber or plastered surface : With super gloss (hi-gloss) , (iv) Two coats (with any shade except white) |
| 84 | Painting block letters or digits in Black Japan or any approved paint as per direction.b) Size above 2.5 cm. and upto 4 cm. |
| 85 | M.S. structural works in columns , beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS:808 & SP(6)-1964 connected to one another with bracket, gusets, cleats as per design, direction of Engineer-in-Charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS:816-1969 & IS 1995 using electrodes of approved make and brand conforming to IS:814-2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as elctrodes, gas and hire charges of all tools and plants and labour required for the work including all incidental charges such as electricuty charges, labour insurance charges etc. I) For structural members of specified sections weighing less than 22.5 Kg./m For fixing main switch, starter, bus bar box, wooden plank for fuse units and Mild Steel Joist (ISMB150 on RCC pillar at the roof) |
| 86 | Supplying Fitting& fixing UPVC pipes A-5 Type and fittings conforming to IS 13592-1992 with all necessary clamps nails , including making holes in walls floors etc. Cutting trenches in any soil through masonary concrete structure etc. If necessary and mending good damages including joining with jointing materials (Spun Yam, Valamoid/Bitumen/M-seal etc.) complete |
| 87 | A) UPVC Pipes (i) 75 mm Dia. |
| 88 | Supplying fitting and fixing of UPVC Plain Tee (i) 75 mm Dia. |
| 89 | Supplying fitting and fixing of UPVC Bend 87.5 degree (i) 75 mm Dia. |
| 90 | Supplying, fitting and fixing including transportation of sign board made of 3 mm thick MS plate of size 300 mm x 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-1) including cutting, welding and writting of both sides of Sign board. Base - Yellow, and words - Red. Bothbottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soling. This will include one materials and labour complete as per drawing and direction of E.I.C. |
| 91 | Electrical wiring Supplying and fixing 16A kit kat rewireable fuse. |
| 92 | Supplying , fitting & Fixing 350mm x 250 mmx25 mm size Wooden Plank on wall ( for fitting & fixing of electrical equipments as necessary on the plank) |
| 93 | Supplying Fixing 15/16 A (Havells Make.) 240 V DP with fuse on L&N Sheet steel Main Switches on flat iron frame on wall. . |
| 94 | Distribution wiring from 15/16A DPIC main switch to Busbar box in 1.1 KV grade single core stranded ‘FR’ PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25 mm PVC casing-capping (precision make) incl. Necy. PVC clips, fitting etc. (c) 2 x 36/0.3 (2.5 sq.mm.)+1x22/0.3(1.5 sq.mm.) |
| 95 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sq.mm.) single core stranded ‘FR’ PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3(1.5 sq.mm.) single core stranded ‘FR’ PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fitting etc. to light/fan/call bell point with pian key type switch (Anchor make) fixed on sheet steel fabricated switch board with /Bakelite top cover. On wall incl. necy. connections and making earthing attachment and mending good damages to building works [ PVC casing-capping and Switch board both on surface] (a) Average run 5 mtr |
| 96 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sq.mm.) single core stranded ‘FR’ PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3(1.5 sq.mm.) single core stranded ‘FR’ PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fitting etc. to 5A 3 pin flush type plug socket with piano key type switch (Anchor make) fixed on sheet steel fabricated CRC MS switch board with Bakelite/Perspex (wall matching color) top cover of 3 mm thick flushed in wall by housing the board after cutting brick wall incl. necy. connection making earthing attachment. Painting and mending good damages to building works [PVC casing-capping and plug box both on surface] (b) Average run 1.5 mtr |
| 97 | Supplying & Fixing bulk head light fitting (Havells/Bajaj make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8 watt CFL lamp complete set. |
| 98 | Supplying, fitting & fixing of 100 Amps, 415V rewireable type porcelain body Fuse top & base complete set conforming to IS: 13947/Part- 4/Sec-1/1993 over wooden plankl board on wall and making necessary connection with the electrical cable as per direction of the E.I.C. |
| 99 | Meter loop connection with 1.1 KVGR 3.5 core/ 4 core 10 sq.mm. to 50 sq.m. PVC insulated and sheathed and armored AI/CU cable from Meter to incoming TPN Main Switch / Terminal (Brand Gloster/Havell/Finolex)(1) 25 sq. mm. 3.5 core XLPE/PVC insulated armoured Copper Cable from meter to 100 Amp. Fuse termina |
| 100 | Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting |
| 101 | Fixing only 100 Amps 415V TP/TPN sheet steel Main Switch (Rewireable types) change over on Flat Iron Frame/Angle Iron Frame on wall on angle iron frame. [Main switch will be supplied departmentally] |
| 102 | Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl.earthing attachment and painting as required – (As per Drawing no. 470 of PWD Specification (a) 4 bar, 415 V, 100/125 A, Dimension of Al. bars [85mm long]: 4 x 25x5mm, Dimension of Sheet Metal Box: 500x150mm |
| 103 | Fitting & Fixing of (DOL or Start-Delta/Auto-Transformer) with Nuts & bolts fixed on Angle on frame on wall and making necessary connection with the electrical equipments ii) Star-Delta/Auto-Transformer starter (above 15 H.P. upto 25 HP) [ Starter will be supplied departmentally] |
| 104 | Earthing with 50 mm dia. GI pipe 3.64 mm thick x 3.04 mtrs. long and 1x 4 SWG G.I.(Hot Dip)wire ( 4 mtrs. Long), 13 mm dia. X 80 mm long G.I. bolts, double nuts and double washers including S & F 15 mm dia. G.I. pipe protection (1 mtr. long) to be filled with bitumen, partly under the ground level and partly above the ground level, driven to an average depth of 3.65 metre below the ground level as below.(a) By ISI- Medium G.I. pipe |
| 105 | Supplying & fixing earth busbar of galvanized(Hot Dip) M.S. flat 25 mm x 6mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with G.I. bolts, nuts, washers, spacing insulators etc. as required. |
| 106 | Connecting the equipments to earth busbar including S & F GI ( Hot Dip ) wire of size as below on wall/ floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.(a) Solid GI wire (iii) No. 8 SWG |
| 107 | Fixing only Volt meter and Ammeter with necessary screws and other fixing materials including making holes where necessary and making connection. |
| 108 | Indicator Modular type. |
| 109 | Supply & Fixing EI danger board on wall b) 20 cm x 30 cm (8\\"x12\\") |
| 110 | Insulation testing of internal wiring of Pump House/Kiosk Box including wiring of electric Motor & other ancilary equipments by means of Megger |
| 111 | Joining water proof cable with the leads of the motor including soldering withrequisite water proof insulation and proper joining compoundNulcanized rubber tape so that proper water proof insulation is assured. |
| 112 | Withdrawal of electro motor submersible pumping set of following capacities from within the tubewell housing pipe of the fOllowing length by using all necessary requisites tools and plants and carefully as per direction of Engineer-in-Charge and stacking the same properly at site within the tubewell premises complete.(a) 100/150/200 cubic metre per hour capacity electro motor pumping set.(i) Length of pump assembly not exceeding 18 metre length. |
| 113 | Installation of submersible electro motor pumping set of following capacities by using necessary requisite, tools and plants by lowering the same within the tubewell housing pipe upto the following depth as per direction by fitting, fixing column pipes and other accessories, fixtures with necessary nuts, bolts and washers and suspending the entire assembly of pump set vertically by fixing the same supported by M.S. clamps over the top of housing pipe, binding the motor cable with each column pipes and drawing cable upto pump controller/starter point including opening out of the top cap of housing pipe of the tube well and testing of motor both in loading as well as in unloaded condition before and after installation of the same. (The rate is inclusive of hiring charges of tools & plants.)(a)100/150/200 cubic metre per hour capacity electro motor pumping set.(ii) Length of pump assembly of any length exceeding 18 metre length. |
| 114 | Add Extra @ 3 % on item no. 21 to 62 exept item no. 26, 29, 37, 38, 39, 40, 41 |
| 115 | Add Extra @ 5 % over schedule rate as district charge on PWD Electrical items no. items no. 63, 65, 66, 67, 68, 69, 72, 73, 74,76, 77, 78, 81 |
| 116 | Add GST @ 18% (on item no 20 to 87) |
| 117 | Add cess @1% (on item no 20 to 88) Please Enable Macros to View BoQ information |