| 1 | Boring with 200mm i/d casing pipe for tubewell in all soils except ordinary hard rocks requiring balsting including removing the casing pipe after the tube well is lowered and tested equipement as required such as hand boring machine and its accessory, transportation to site and vice versa etc complete in all respect. |
| 2 | Boring with 200mm i/d housing pipe |
| 3 | Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore. |
| 4 | 150mm nominal diameter (weight 21.6 kg per metre) 5.4 mm thickness |
| 5 | Supplying, Fixing & lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell bore. |
| 6 | 150mm Steel Strainer (slot size 0.15/0.20mm) 5.0 mm thickness |
| 7 | Supplying, Fixing & lowering of Stainless Steel Socket as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell bore complete in all respect. |
| 8 | 150mm internal diameter |
| 9 | Supplying & Fixing of bail plug of M.S pipe complete with inverted U-hook attched to the bottom plug complete in all respect. |
| 10 | 150mm internal diameter (weight 21.6 kg per metre) 5.4 mm thickness |
| 11 | Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect. |
| 12 | 150mm internal diameter |
| 13 | Supplying and fixing of well cap having threads to fix on housing pipe.Complete in all respects |
| 14 | (150mm i/d) |
| 15 | Supplying and fixing of mild steel clamps of size 150 mm x 12mm made out of MS Flat 1.52m) long, suitable to fit housing pipe including the cost Nut & Bolt of Suitable size complete in all respects |
| 16 | Supplying at site wooden box of suitable size with lid and locking arrangement for preserving strata sample collected from the bore. |
| 17 | Testing of Water Sample for heavy metal from approved laboratory (Toxic material sucha as arsenic, lead, mercury, presticide etc.) |
| 18 | Development and stabilizing of the tube-well with Air Compressor of required capacity as directed by the Engineer-in-charge including cost of tools appliances and consumable to the satisfaction of Engineer-in-charge. |
| 19 | Capacity of Air Compressor 300cfm at 250 PSI |
| 20 | Development and stabilizing of the tube-well with Submersible Pump of required capacity as directed by the Engineer-in-charge including the cost of tools appliances and consumable to the satisfaction of Engineer-in-charge. |
| 21 | Collection of water sample from different strata and testing of sample from approved laboratory (Physical & chemical Analysis) |
| 22 | Provision for Sanitary Clay Seal and sterilization of tubewell as per IS code : 2800-2019 |
| 23 | Construction of Pump Chamber size 2.50x2.50m with including electric wiring as per analysis, complete in all respects. Extra for provision for Sanitary Latrine in pump chamber for foundation and plinth of WC rooms including flooring, PVC pipes, Junction Box , 1 No. Leach Pit , Super structure WC room etc. |
| 24 | Construction of Gravel Pit outside the Pump Chamber. (0.90m Dia.) as per standard design & drawings of public health department |
| 25 | PUMPING MACHINERY |
| 26 | Providing & installing, testing & commisioning of 1 no electrically driven Submersible Pump set of KSB or equivalent make of 5 BHP along with electric panel board consisting of electrical appliances such as automatic Star Delta Push Button or oil imeersed starter,Main Switch, VM, AMpere Meter, ELCB, Shunt capacitor. Single phase, preventer, Indicating lamps, Kit-Kat etc. including G.I. column Pipe of IS 1239-2004 medium class suitable size 50 mm & length 22mtr (in 3.00 mtr lengths each with flanges,screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable of 65 mtr length and 2.50 mm2 size as per IS694-1990 reaffirmed 2000 complete in all respects |
| 27 | Rate of Motor with Pump |
| 28 | Panel Board |
| 29 | Submersible cable Size 2.50mm2 |
| 30 | Column Pipe (G.I) 50mm i/d |
| 31 | Providing & Installing 80mm mm dia delivery main (from Tube-well to duck foot bend including cost of C.I.D/F Pipes, D/F Sluice Valves, D/F Non Return Valve & Specials as C.I. Bends, Tail Piece Tees, Pressure gauge, Air Valve,,V notch haudi etc. inside the Pump chamber as per DWSS standard design and analysis complete in all respects. (Annexure-3) As per IS1536-2001 & 1538-1993 reaffirmed 1999 and electro steel Casting/Kesoram pipe make). |
| 32 | Providing Installing testing and commissioning and one no. electronically actuated, diaphragm operated, metering system, chemical dosing chlorinator, suitable for delivering 0.5 to 6 liter of bleaching powder solution/ sodium hypo solution per hrs under maximum deliver pressure upto 7kg/cm2 and suction left not less than 1.5 meter. |
| 33 | Providing, Laying , fixing & jointing of uPVC. Pipes & specials 6kg/sqcm Type A as per ISI-4985-2021 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including cost of earth work in excavation & back filling as per analysis A 14 complete in all respects. |
| 34 | 90mm i/d (Mechanical) |
| 35 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS1410) and Bronze(gunmetal) working parts sluice valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge). |
| 36 | 80 mm i/d |
| 37 | Consturction of masonary Sluice valve chamber excluding Sluice valve cover as per standard design & drawings of pubic health department. |
| 38 | (a) Size 0.9 m. x 0.9 m. |
| 39 | Providing & fixing 1.2mtr high fencing around the head works site with 1.65 meter post, placed every 2.5 meters apart, embedded in cement concrete blocks and every tenth post to be strutted with three rows of G.I. Barbed wire weighing 14 Kg per 100 meters (minimum) and fixing with GI staples tied to 6mm bar nib, with binding wire or by providing cut, including drilling holes in the post, including cost of posts, winding wire, strutted earth work in the post & aluminum painting complete in all respects as per DWSS standard Drawing and analysis. |
| 40 | Providing and Fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI marked wire 4 mm dia fencing pole size at bottom 4\\" x 3\\", size top 3\\" x 3\\",Lenght 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respects. |
| 41 | Providing & fixing D-Hook complete with MS Bolts size 300mm x 18mm as per DWSS standard Drawing and analysis. |
| 42 | Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per DWSS standard Drawing & Analysis. |
| 43 | Construction of masonry gate pillar including cost of MS Steel Gate size 1.22 m x 1.37 m as per DWSS standard Drawing and analysis. |
| 44 | Construction of Foot Path with masonry toe wall & earth filling and Cement Concrete 1:8:16 with 40 mm gauge stone aggregate, 40 mm thick cement concrete topping 1:2:4, inside water works as per DWSS standard Drawing and analysis. |
| 45 | Providing & fixing MS sign Board as per DWSS standard design and analysis. |
| 46 | Providing, Laying , fixing & jointing of uPVC. Pipes & specials 6kg/sqcm Type A as per ISI-4985-2021 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including cost of earth work in excavation & back filling as per analysis A 14 complete in all respects. |
| 47 | Excavation with Mechanically |
| 48 | uPVC Pipe 63 mm o/d |
| 49 | uPVC Pipe 75 mm o/d |
| 50 | uPVC Pipe 90 mm o/d |
| 51 | uPVC Pipe 110 mm o/d |
| 52 | Excavation with Manually |
| 53 | uPVC Pipe 63 mm o/d |
| 54 | uPVC Pipe 90 mm o/d |
| 55 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS1410) and Bronze(gunmetal) working parts sluice valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge). |
| 56 | 80mm i/d |
| 57 | Consturction of masonary Sluice valve chamber excluding Sluice valve cover as per standard design & drawings of pubic health department. |
| 58 | (a) Size 0.6 m. x 0.6 m. |
| 59 | Hand boring Horizontly for crossing of pipe under road or any other obstacle by using Auger/Bocki method.Including excavation, stringing and jointing of pipe upto 160mm complete |
| 60 | Contractor shall be quote rates only for dismantling of mettaled road & back filling with excavated earth fully compacted the restoration of the mettaled road to its original condition will be done by the concerned department i.e. PWD (B&R) PMB/Panchayati Raj) |
| 61 | 90mm o/d 10 No road cut x 4 mtr = 40+280 = 320M |
| 62 | Dismantling and restoration of Cement Concrete Road including breaking, removal, stacking of serviceable material, disposal of debris, preparation of sub-base, and restoration of interlocking road to original condition, complete in all respects, as per DWSS standard approved analysis. |
| 63 | 63/75/90/110mm o/d |
| 64 | Dismantling of existing interlocking / cement concrete in multiple layers/ brick road multiple layers, including breaking, removal, stacking of serviceable material, disposal of debris, preparation of sub-base, and restoration of interlocking road to original condition, complete in all respects, as per DWSS standard approved analysis. |
| 65 | 63/75/90/110/160mm o/d |
| 66 | Household water connection ISI Marked, |
| 67 | Providing proposed water connection to house hold up to wall with providing laying, jointing, testing MDPE pipe line 15mm o/d & GI 15mm i/d , including cost of cutting hole in walls, specials such as tees, bends, sockets, union, elbow & GI Hooks etc, cutting threading and testing in trenches in the ground and ISI marked 15mm i/d GM ferrule as per IS:2692 and 3'' i/d clamp with 15mm i/d C.I. bib cock as per IS:210 with stainless steel spindle of approved make as per CSR 30.65 (b) complete with excavation |
| 68 | Water Connection on Existing/ GI pipeline, |
| 69 | O&M cost for 3 Months after commissioning for making the scheme sustainable |
| 70 | CARRIAGE OF MATERIALS: |
| 71 | Extra Carriage of Fine Aggrigate payable upto lead 35 Km |
| 72 | Extra Carriage of Course Aggrigate (Bajri) payable upto lead 35 Km |
| 73 | Extra Carriage of Bricks payable (7.195*1000=7195) |
| 74 | ENVIRONMENTAL PROVISION |
| 75 | Surface dressing of ground including removing rank vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m in all kinds of soil. |
| 76 | Supplying and planting permanent trees in prepared pits and watering |
| 77 | planting seeding including digging of beds to 15cm depth and mixing FYM, fertlizer and insecticides, planting of seedings at 20cm distance from plant to plant and row to row. |
| 78 | planting ground covers (ordinary) including digging of beds to 15cm depth and mixing FYM, fertlizer and insecticides, planting of sapling at 25cm distance from plant to plant and row to row. |
| 79 | Providing for one way stand post with Khura complete in all respects. Please Enable Macros to View BoQ information |