| Sl. No. | Item Description |
| 1 | Civil Work |
| 2 | Dismantling Brick/Tile Work Dismantling of existing structures like culverts, bridges, retaining walls and other structures comprising of brick masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. Cement mortar |
| 3 | Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications. Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.in Ordinary soil upto depth 3 m depth |
| 4 | Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications. Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.in Ordinary soil 3 m to 6 m depth |
| 5 | Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 m Excavation for roadwork in soil with hydraulic excavator of 0.9 Cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections,and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per Technical Specification Clause 302.3 |
| 6 | Dewatering from foundation of abutments and wingwalls (with pump capacity4000 lit perHr.) includingwagesof operator and fuel including supplyofallmaterial, labour and T&P etc. required for proper completion of the work. |
| 7 | Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8. Granular material . |
| 8 | Cement concrete blocks (Providing and laying of apron with cement concrete blocks of size as per Table 1300.1 cast-in-situ and made with nominal mix of M-15 grade cement concrete as per drawing and technical specifications Clause 1301.) |
| 9 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203.P.C.C grade M 10. Nominal mix 1:3:6 |
| 10 | Providing and laying flooring laid over cement concrete bedding complete as per drawing and technical specification Clause 1303 (Cement concrete bedding M-10 to be taken as per design and Paid Separately) Rubble stone laid in cement mortar 1:3 |
| 11 | Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications RCC Grade M35 With Batching Plant, Transit Mixer and Manual placing |
| 12 | Supplying, fitting and placing TMT bar reinforcement in sub-structure complete as per drawing and technical specifications |
| 13 | Stone masonry in cement mortar for substructure complete as per drawing& technical specification Clauses 702, 704, 1202 and 1204 In cement mortar (1:5) |
| 14 | Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications. RCC Grade M35 Height upto 5m With Batching Plant, Transit Mixer and Concrete Pump |
| 15 | Providingand layingof wirecrates3.00x1.50x1.50 insizewithGI wire conforming to IS:280 & IS:4826 in150mm x150 mm mesh laid with stone boulders. as per direction of Engineer-in- charge. (As per PWD Uttarakhand specifications GI wire 8 gauge BWG |
| 16 | Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and line aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm. aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vihratniv miler finishing and curing.) |
| 17 | Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications R.C.C. Grade Slab M25 |
| 18 | Geotextile Filter (Laying of a geotextile filter between pitching and embankment slopes on which pitching is laid to prevent escape of the embankment material through the voids of the stone pitching/cement concrete blocks as well as to allow free movement of water without creating any uplift head on the pitching.) |
| 19 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with greycement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick |
| 20 | 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 ( 1 cement : 5 coarse sand ) with joints finished flush. Red sand stone. |
| 21 | 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints finished flush. Red sand stone. + Extra for sand stone in treads of steps and risers using single length above normal size up to 2.00 metre but in Ghat areas |
| 22 | Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. |
| 23 | 30 mm thick (Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Red sand stone - Exposed face machine cut and table rubbed with rough backing.) |
| 24 | Decorative Inlays - Brass/Stone Inlay - Symbolic motifs of MaaGanga, Om, swastik patterns in threshold spaces Providing and laying machine cut, mirror polished Marble stone flooring, in required design (Simple geometrical, abstract etc.) and in patterns in combination with Italian marble stones of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm, including pointing with white cement slurry admixed with pigment to match the marble shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadoreetc. |
| 25 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red |
| 26 | ProProviding edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 27 | (Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. ) R.C.C. grade M 25 |
| 28 | Excavation in Cutting in Soil by manual means with lead upto 50 m (Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3) |
| 29 | SS Anchor Fasteners (RCC / Brick) – M-8x100 mm |
| 30 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 31 | Providing and fixing Stainless Steel (Grade 304) 6mm dia Solid Chain made of Solid Rod etc, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 32 | Excavation in Cutting in Soil by manual means with lead upto 50 m. (Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3) |
| 33 | Stone work ashlar sunk or moulded or sunk and moulded upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : |
| 34 | Extra for stone work ashlar sunk or moulded or sunk and moulded or carved in Circular or polygonal pillars |
| 35 | Extra for stone work ashlar sunk or moulded in cornices. |
| 36 | Furnishing and Placing einforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification RCC Grade M25 Using Batching Plant, Transit Mixer and Concrete Pump For T-beam & slab,(p) Height upto 5m |
| 37 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 38 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. |
| 39 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 40 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 41 | Supplying and filling in plinth with Jamuna sand under floors, including watering, ramming, consolidating and dressing complete. |
| 42 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 43 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources). |
| 44 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 45 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 46 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : in cement mortar 1:6 (1 cement : 6 coarse sand) : |
| 47 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 48 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 49 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M30 grade with minimum cement content of 350 kg /cum |
| 50 | Reinforced cement concrete work in arches, archribs, domes, vaults, shells, folded plate and roofs having slope more than 15° up to floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 51 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 52 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 53 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 54 | Centering and shuttering including strutting, propping etc. and removal of form for suspended floors, roofs, landings, balconies and access platform |
| 55 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 56 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 57 | Arches, domes, vaults up to 6 m span |
| 58 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) sqm 347.05 |
| 59 | 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) |
| 60 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 61 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 62 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr/10 sqm |
| 63 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 64 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 65 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B Fixing with adjustable lugs with split end tail to each jamb |
| 66 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) nondecorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 67 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever quired) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required)shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231shall be paid separately.Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3 (ii) Sites with structure height more than 20m for all wind speeds Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.Using R3 series with frame (98mm & above) x (40mm & above) & both glazed and fly screen sash (30mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system, (Height upto 1.8m). |
| 68 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125mm |
| 69 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) 125mm |
| 70 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mm |
| 71 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete 300x16x5 mm |
| 72 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour andshade, with necessary screws etc. completeTwin rubber stopper |
| 73 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 74 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc, complete. |
| 75 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 76 | Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : With residual type petroleum bitumen of grade VG -10 |
| 77 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 78 | Crazy ceramic tile flooring, with under layer 12 mm thick cement mortar 1:4 (1 cement: 4 coarse sand), with joints not exceeding 5 mm, including filling the gaps with ordinary cement mixture & mixing with synthetic polyester fibre, triangular in shape having specific gravity of 1.34 to 1.40, cross section size ranging from 10 to 40 micron & length upto 6 mm , mixing fibre @ 125 grams per 50 kg of cement in cement mortar, including providing and mixing water proofing material in mortar @ 1 kg per 50 kg of cement, all complete as per direction of Engineer-in-charge. |
| 79 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 110 mm diameter |
| 80 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Coupler(110 mm) |
| 81 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.5 degree110 mm diameter |
| 82 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.Shoe (Plain) 110 mm Shoe |
| 83 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs,screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 84 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 carse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - exposed face fine dressed with rough backing 40 mm thick |
| 85 | Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by engineer-in-Charge and consisting of : (i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) including applying of twice ( at base and top of mortar ) cement slurry @ 2.2kg/m2 (each time) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. (iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. Using rough kota stone. |
| 86 | Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : Using rough Kota stone |
| 87 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality H D - 20,Circular shape 560 mm internal diameter |
| 88 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 89 | Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately).18mm thick |
| 90 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 75x65x4 mm (heavy type) |
| 91 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378 , 100 mm |
| 92 | Providing and fixing 2nd class teak wood lipping/ moulded beading or taj beading of size 18X5 mm fixed with wooden adhesive of approved quality and screws/nails on the edges of the Prelaminated particle board as per direction of Engineer-in-charge |
| 93 | Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. |
| 94 | Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust)with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. Red Sand Stone |
| 95 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete. |
| 96 | Stone Carving on Red send stone with approved dessign and drawnig complete in all respect as per direction of engineer -in- charge |
| 97 | excavation of earth below GL by manually or by mechanical means for laying of sewers ,manholes ,gully pits,chambers etc in soil including extra excavation below inverts trimming and dressing of sides ,levelling and backfilling of trenches by excavated earth in 20 cm layers watering and ramming the same including removing of surplus earth and other dismantled material upto a distance of 50 meter from the centre of trenches and cleaning of sides properly after completion of the work .exacavation by mechanical means shall be restricted upto 90 cm above invert level at every point of excavation.excavation from invert level to 90cm above shall be done be manually onlySame as item no 1 but excavation in soil mixed with morum,shingle & kankar etc using of any specials T&P if required . 0 to 1.50 m below G.L |
| 98 | excavation of earth below GL by manually or by mechanical means for laying of sewers ,manholes ,gully pits,chambers etc in soil including extra excavation below inverts trimming and dressing of sides ,levelling and backfilling of trenches by excavated earth in 20 cm layers watering and ramming the same including removing of surplus earth and other dismantled material upto a distance of 50 meter from the centre of trenches and cleaning of sides properly after completion of the work .exacavation by mechanical means shall be restricted upto 90 cm above invert level at every point of excavation.excavation from invert level to 90cm above shall be done be manually onlySame as item no 1 but excavation in soil mixed with morum,shingle & kankar etc using of any specials T&P if required . 1.5 to 3.0 m below G.L |
| 99 | Open timbering ,P/F of open timbering (covering One third of surface area by planks) in trenches for following depths below G.L consisting of 40 mm thick approved country wood planks for polling board 125 mm x 75 mm indian sal wood walers and 100 mm dia sal wood ballies for struts at 1.50m interval including removal after laying of sewer(both sides of trenches will be taken as one side for the purpose of payments & measurements i.e. area equals to length x depth of trenches. Dismantled timbering materials will be the property of the contractor.Depth upto 3 m below G.L |
| 100 | Supply & Laying - Jointing of following dia. R.C.C. S&S pipes with rubber gaskets to the site of work, lowering the same into trenches below ground level true to alignment, making the joints with rubber gaskets and with necessary spun yarn soaked in bitumen jointing with 1:2 cement mortar in coarse sand including cost of all jointing materials and testing etc. complete but excluding excavation and backfilling of trenches upto ground level.(Class NP3)300 mm dia0-1.5 m depth |
| 101 | Supply & Laying - Jointing of following dia. R.C.C. S&S pipes with rubber gaskets to the site of work, lowering the same into trenches below ground level true to alignment, making the joints with rubber gaskets and with necessary spun yarn soaked in bitumen jointing with 1:2 cement mortar in coarse sand including cost of all jointing materials and testing etc. complete but excluding excavation and backfilling of trenches upto ground level.(Class NP3)300 mm dia1.5-3.0 m depth |
| 102 | Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : |
| 103 | 0.91 m deep with S.F.R.C. cover and frame (heavy duty,HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete.(Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 |
| 104 | Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 105 | Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete.(Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 106 | Extra depth for circular type manhole 1.22 m internal dia (at bottom)beyond 1.68 m to 2.29 m :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 107 | Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) finished with a floating coat of neat cement, all complete as per standard design :2.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete.(Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 |
| 108 | Extra depth for circular type manhole 1.52 m internal dia (at bottom)beyond 2.30 m :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 109 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar |
| 110 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) |
| 111 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250 mm diameter |
| 112 | Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) :Circular manhole 140 cm dia with circular cover 600 mm dia of grade EHD - 35 |
| 113 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 114 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions,total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick withcement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 |
| 115 | Extra for depth beyond 45 cm of brick masonry chamber : For 455x610 mm size With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 116 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 15 mm dia nominal bore |
| 117 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 20 mm dia nominal bore |
| 118 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 25 mm dia nominal bore |
| 119 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm dia nominal bore |
| 120 | Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 15 mm dia nominal bore |
| 121 | Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 20 mm dia nominal bore |
| 122 | Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 25 mm dia nominal bore |
| 123 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 124 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore |
| 125 | Providing and fitting mono block pump set 2900 rpm ,3 phase Kirloskar make or equivalent i/c fitting etc 5.0 Hp |
| 126 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 1000 mm dia. R.C.C. pipe |
| 127 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 128 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 129 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 130 | Spreading of Sludge Farm Yard Manure or/and good Earth (Spreading of sludge farm yard manure or/ and good earth in required thickness (cost of sludge, farm- yard manure or/and good earth to be paid for separately)) |
| 131 | Making Lawns including Ploughing and Dragging with 'Swagha' Breaking of Clod (Making lawns including ploughing and breaking of clod, removal of rubbish, dressing and supplying doobs grass roots and planting at 15 cm apart, including supplying and spreading of farm yard manure atrate ofO. 18 cum per 100 sum) |
| 132 | a) Planting Permanent Hedges including Digging of Trenches (Planting permanent hedges including digging of trenches. 60 cm wide and 45 cm deep, refilling the excavated earth mixed with farmyard manure, supplied at the rate of 4.65 cum per 100 metres and supplying and planting hedge plants at 30 cm apart) |
| 133 | Planting of Treesand their Maintenance for one Year (Planting of trees by the road side (Avenue trees) in 0.60 m dia holes. 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge mannure, planting the saplings, backfilling the trench, watering, fixing the tree guard and maintaining the plants for one vear) |
| 134 | Edging with 2nd class Bricks, laid dry lengthwise (Edging with 2nd class bricks, laid dry lengthwise, including excavation, refilling, consolidation, with a hand packing and spreading nearly surplus earth within a lead of 50 metres) |
| 135 | Tree Guard with MS Iron (Providing and fixing MS iron tree guard 60 cm dia and 2 metre high above ground level formed of 4 Nos (25 x 6 mm) and 8 Nos (25 x 3 mm) vertical MS riveted to 3 Nos (25 x 6 mm) iron rings in two halves, bolted together with 8 mm dia and 30 mm long bolts including painting two coats with paint of approved brand over a coat of primino. complete in all respects.) |
| 136 | Constructing rain water harvesting recharge trench cum recharge shaft I well including grating passage joining storm water drain and trench having brick walls. RCC cover slab and filled with layers of filter media (size 75 mm to100 mm), grating having brick walls and CC 1:2:4 base and PVC pipe shaft packed with gravel, provided with wire screen and bottom plug complete as per Drawing, direction of the Engineer and MORT&H Specifications sections300, 1000, 1300, 1500, 1600 & 1700,(Dimension of rain water harvesting pit 6.5 m depth, 2.10 meter inner dia, wall width 375 mm and top slab thickness 150mm) |
| 137 | Cast in Situ Cement Concrete M20 kerb (Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409) PCC M20 for Kerb (Cast in Situ) |
| 138 | Providing and Fixing Automatic Fire Larm System As per CPWD’s General specification for Electrical Works, Part-VI Fire detection and Alarm system-2018, NBC 2016, local Fire Bye Laws, IE Rules, BIS/IEC, Indian Standards amended uptodate; covering Manual/ Automatic Fire Alarm System complete with items like detectors, manual call boxes, cabling/ wiring, fire panels, etc. including Integration of FAS panel with Smoke Ventilation & pressurization fans, AHUs, Lifts, sprinkler monitoring panel, water curtain system, water levels of Fire water tanks and as required for any other service complete in all respect as per direction in charge |
| 139 | Precision Air Conditioning system air conditioning system shall be complete with all equipment, all controls, indoor and outside units, monitoring unitsand complete installation and commissioning, inclusive of all auxiliary works like ducting, inlet and drain piping, piping between indoor and outdoor, cabling, acoustic and thermal insulation (Duct and floor for server room), volume control dampers, supply and returns air grills,stands for indoor and outdoor units with related civil works etc. as per the site requirements. Automatic monitoring and control of cooling, heating, humidification, dehumidification, air-filtration, etc. shall be installed to achieve the required temperature and humidity conditions. |
| 140 | Providing and Fixing IP based CCTV system for building security comprising of PTZ/ fixed camera, cabling, digital recording, HD display system with minimum display of 5” x 8” per camera and hardware & software support both for indoor and external surveillance IP based Closed Circuit Surveillance system is proposed to monitor the activities at critical/ desired areas. The video shall be continuously transported to existing server, using IP cameras; The items supplied by the contractor should have specifications compatible with each other required for satisfactory operation of the system. CCTV cameras and storage server/ NVR shall have ONVIF Profile-S compliance for interoperability.Indian standard 13252 Complete in all respect as per direction of engineer incharge. |
| 141 | Providing and Fixing HVLS Fan (3 m Radius) complying and containing all applicable standard complete in all respect as per direction of engineer incharge. |
| 142 | Providing and Fixing fully automatic organic Waste Converter capacity 500 kg per day of segregated organic waste with use of micro-organism complying and containing all applicable standard complete in all respect as per direction of engineer incharge. |
| 143 | Providing and Fixing Dustbins - SS Duo Dustbin 2 in 1 capacity (60+60) Ltr. With S.S. grade 304 weight should be 20-22 Kg approax. complying and containing all applicable standard complete in all respect as per direction of engineer incharge. |
| 144 | Providing and Fixing of Seating- Cast Iron Bench Srating Material -FRP Leg- Cast Iron size 5 feet*2.5 feet*3.5 feet with 8 no. Frp strips weight should be 50 Kg approax. complying and containing all applicable standard complete in all respect as per direction of engineer incharge. |
| 145 | Providing and Installation of Water fountain (as per specification attached) complying and containing all applicable standard complete in all respect as per direction of engineer incharge. |
| 146 | Providing and fixing Water Cooler 150 Ltr. Storage with 2 taps in S.S. body complying and containing all applicable standard complete in all respect as per direction of engineer incharge. |
| 147 | Providing and Installation of prefabricated Toilet complex including men & women toilet, a lobby, changing room, urenals, baby feeding room, disabled-friendly toilets, caretaker room and washbasin cabins (as per specification attached) complying and containing all applicable standard complete in all respect as per direction of engineer incharge. |
| 148 | Providing and Fixing16 Meter Flag Mast round Pole of mild steel complying and containing all applicable standard complete in all respect as per direction of engineer incharge. |
| 149 | Designer work on Red sand stone for Entrance gate as per drawing & design provided complete in all respect as per the direction in engineer incharge. |
| 150 | Designer work on Red sand stone for Krishna Chariot plateform as per drawing & design provided complete in all respect as per the direction in engineer incharge. |
| 151 | Shifting of existing Shri Krishana- Arjun Chariot established at Triveni Ghat Rishikesh within a distance of 100 m including all cost of required arrangements to be made for safely shifting likewise deploying mechanical lifts, dismounting, hoisting, pushing & pulling devices, firm shifting structure, skilled man power and necessary repair works for the damage (if any) caused during the process of shifting to maintain the aesthetic look of sculpture and repaint the sculpture, after reestablishing Chariot on the readymade platform of approx. 3 m height complete in all respect as directed by the engineer in charge. |
| 152 | Electrical Work |
| 153 | SITC of 20W multi color spot light, Protection Rating : IP66, complying to BIS standard \\"IS 10322 (Part 5/Sec 1): 2012\\" and having CE certification against standard \\"Low Voltage Directive & Protective Equipment - EN 60598-1:2015\\", and \\"Electromagnetic Compatibility Directive - EN 61547: 2009\\", Mounting Structure : Adjustable wall mount yoke arrangements for fixing the lights. Power consumption : 20W, CCT : RGBW, (as per the design approval) Optics : PMMA with holder, Beam Angle : 25º/45º/60º, Control : DmX512 Channel : 4 CH, Body : Die casted / extruded aluminium with embossed manufacturer logo, Seperate compartment for keeping the decoder/driver in the housing, Hot spot and light distribution : Optics Designed to minimize hot spots & fringing in color mixing applications. Power Input : DC 24V with external driver, Surge Protection : Inbuilt surge protection 2KV-4KV(Additional if required will be added as per the requirement), Toughened transparent glass having the IK protection up to IK05, Painting : Chemical 3/7 tank processed treatment before the powder coat black/ash/approved color coat. Fixture will be suitable to operate in a temperature range of 0°C to 50°C , LED life should be at least 50,000 burning hours at L70 at 25 degree centigrade. Luminaire is inclusive of Integral male/female waterproof connectors with structures in pre wired conditions as per IS standard. PCB thickness must be 1.6mm, 35 micron Copper, 2W TC with Black or White masking, Copper /OSP finish. LM79, IK05, IP66, HV Certificates from NABL Acrediated laboratory. LED Makes should be CREE, LumilLED, Osram, Seoul, Nichia or equivalent with the engineer or 3rd party testing laboratory approval. Power & DMX Loop In/Out along with IP67 connector having the length >400mm. |
| 154 | SITC of high quality long through multi color wash light, Protection Rating : IP66, complying to BIS standard \\"IS 10322 (Part 5/Sec 1): 2012\\" and having CE certification against standard \\"Low Voltage Directive & Protective Equipment - EN 60598-1:2015\\", and \\"Electromagnetic Compatibility Directive - EN 61547: 2009\\", Mounting Structure : Adjustable surface mount yoke arrangements for fixing the lights having the rotation degrees embosed in the die cast. Power consumption : 50W, CCT : RGBW(6000-7000K), (as per the design approval), Optics : PMMA with holder, Beam Angle : 25º/45º/60º, Control : DmX512 Channel : 4 CH, Body : Die casted / extruded aluminium with embossed manufacturer logo, Seperate compartment for keeping the decoder/driver in the housing which can be easily removable for service without disturbing the LEDs/Optics, Hot spot and light distribution : Optics Designed to minimize hot spots & fringing in color mixing applications. Power Input : Constant DC 24V with external driver to the constant current decoder, Surge Protection : Inbuilt surge protection in the driver 2KV-4KV(Additional if required will be added as per the requirement), Toughened transparent glass having the IK protection up to IK08, Painting : Chemical 3/7 tank processed treatment before the powder coat black/ash/approved color coat. Fixture will be suitable to operate in a temperature range of 0°C to 50°C, The light fixtures are having IP68 air vent made of stainless steel which helps to desiccate & prevent from forming moisture inside the light fixture at worst environmental condition. LED life should be at least 50,000 burning hours at L70 at 35 degree centigrade. Luminaire is inclusive of Integral male/female waterproof connectors with structures in pre wired conditions as per IS standard. PCB thickness must be 1.6mm, 35 micron Copper, 2W TC with Black or White masking, Copper /OSP finish. LM79, IK07, IP66, HV Certificates from NABL Acrediated laboratory. LED Makes should be CREE, LumilLED, Osram, Seoul, Nichia or equivalent with the engineer or 3rd party testing laboratory approval. Power & DMX Loop In/Out along with IP67 connector having the length >300mm. |
| 155 | SITC of high quality long through multi color wash light, Protection Rating : IP66, complying to BIS standard \\"IS 10322 (Part 5/Sec 1): 2012\\" and having CE certification against standard \\"Low Voltage Directive & Protective Equipment - EN 60598-1:2015\\", and \\"Electromagnetic Compatibility Directive - EN 61547: 2009\\", Mounting Structure : Adjustable surface mount yoke arrangements for fixing the lights having the rotation degrees embosed in the die cast. Power consumption : 150W, CCT : RGBW(6000-7000K), (as per the design approval), Optics : PMMA with holder, Beam Angle : 25º/45º/60º, Control : DmX512 Channel : 4 CH, Body : Die casted / extruded aluminium with embossed manufacturer logo, Seperate compartment for keeping the decoder/driver in the housing which can be easily removable for service without disturbing the LEDs/Optics, Hot spot and light distribution : Optics Designed to minimize hot spots & fringing in color mixing applications. Power Input : Constant DC 24V with external driver to the constant current decoder, Surge Protection : Inbuilt surge protection in the driver 2KV-4KV(Additional if required will be added as per the requirement), Toughened transparent glass having the IK protection up to IK08, Painting : Chemical 3/7 tank processed treatment before the powder coat black/ash/approved color coat. Fixture will be suitable to operate in a temperature range of 0°C to 50°C, The light fixtures are having IP68 air vent made of stainless steel which helps to desiccate & prevent from forming moisture inside the light fixture at worst environmental condition. LED life should be at least 50,000 burning hours at L70 at 35 degree centigrade. Luminaire is inclusive of Integral male/female waterproof connectors with structures in pre wired conditions as per IS standard. PCB thickness must be 1.6mm, 35 micron Copper, 2W TC with Black or White masking, Copper /OSP finish. LM79, IK07, IP66, HV Certificates from NABL Acrediated laboratory. LED Makes should be CREE, LumilLED, Osram, Seoul, Nichia or equivalent with the engineer or 3rd party testing laboratory approval. Power & DMX Loop In/Out along with IP67 connector having the length >300mm. |
| 156 | SITC of high quality Multi Color Neon Flexible light, Protection Rating : IP67, Mounting Structure : Adjustable wall mount SS clips for fixing the lights. Power consumption : 12W, CCT : RGB/RGBW, (as per the design approval) Beam Angle : 120º, Control : DmX512 Channel : 4 CH, Power Input : DC 24V with external driver, Surge Protection : Inbuilt surge protection 2KV-4KV(Additional if required will be added as per the requirement), Fixture will be suitable to operate in a temperature range of 0°C to 50°C , LED life time should be at least 50,000 burning hours at L70 at 25 degree centigrade. Luminaire is inclusive of Integral male/female waterproof connectors with structures in pre wired conditions as per IS standard. LED Makes should be CREE, LumilLED, Osram, Seoul, Epistar, Nichia or equivalent with the engineer or 3rd party testing laboratory approval. |
| 157 | SITC of Aluminium Profile for Neon flex |
| 158 | SITC of high quality long through multi color Linear wash light, Protection Rating : IP66, complying to BIS standard \\"IS 10322 (Part 5/Sec 1): 2012\\" and having CE certification against standard \\"Low Voltage Directive & Protective Equipment - EN 60598-1:2015\\", and \\"Electromagnetic Compatibility Directive - EN 61547: 2009\\", Mounting Structure : Adjustable surface mount yoke arrangements for fixing the lights. Power consumption : 80W, CCT : RGBW(6000-7000K), (as per the design approval), Optics : PMMA with holder, Beam Angle : 25º/45º/60º, Control : DmX512 Channel : 4 CH, Body : Die casted / extruded aluminium with embossed manufacturer logo, Seperate compartment for keeping the decoder/driver in the housing which can be easily removable for service without disturbing the LEDs/Optics, Hot spot and light distribution : Optics Designed to minimize hot spots & fringing in color mixing applications. Power Input : Constant DC 24V with external driver to the constant current decoder, Surge Protection : Inbuilt surge protection in the driver 2KV-4KV(Additional if required will be added as per the requirement), Toughened transparent glass having the IK protection up to IK07, Painting : Chemical 3/7 tank processed treatment before the powder coat black/ash/approved color coat. Fixture will be suitable to operate in a temperature range of 0°C to 50°C, The light fixtures are having IP68 air vent made of stainless steel which helps to desiccate & prevent from forming moisture inside the light fixture at worst environmental condition. LED life should be at least 50,000 burning hours at L70 at 35 degree centigrade. Luminaire is inclusive of Integral male/female waterproof connectors with structures in pre wired conditions as per IS standard. PCB thickness must be 1.6mm, 35 micron Copper, 2W TC with Black or White masking, Copper /OSP finish. LM79, IK07, IP66, HV Certificates from NABL Acrediated laboratory. LED Makes should be CREE, LumilLED, Osram, Seoul, Nichia or equivalent with the engineer or 3rd party testing laboratory approval. Power & DMX Loop In/Out along with IP67 connector having the length >300mm. |
| 159 | SITC of DC power driver for the above Lights, Power : 200W, Input : AC 110-240V AC, 50Hz, Output : DC 12/24V, Protection rating, IP67, Surge protection : LL 4KV, LE 6KV |
| 160 | SITC of high quality DMX decoder, Power Input : DC 24V, |
| 161 | SITC of IP driver box made up of PVC / UPVC for the internal terminations and external outgoing connecting points, with required PVC / brass glands, Optional suitable size MCB fitted for control outgoing circuits. |
| 162 | SITC of PVC insulated multi core electrical un armored flexible 5C x 0.5Sq mm power cable having less electrical losses. (As per actuals depending upon the site condition) |
| 163 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required 3C X 1.5 Sq.mm |
| 164 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required 3C X 2.5 Sq.mm |
| 165 | SITC of 5 core DMX cable comprises twisted pairs with shield support for carrying of data. DMX512 cable is used for connecting all light consoles that use DMX 512 standard data transmission. (As per actuals depending upon the site condition) |
| 166 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4C X 25 Sq.mm |
| 167 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required 90mm dia ( OD -90mm & ID 76mm nominal ) |
| 168 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 25 mm dia |
| 169 | SITC of IP65 \\"I\\" power connectors having 3/4 pole cable connector, chuck type strain relief, Current rating 20 A rms continuous, Easy and extremely precise locking system \\"Quick Lock\\" High impact materials - long-lasting and reliable |
| 170 | SITC of IP65 \\"I\\" DMX connectors having 3/5 pole cable connector, Male/Female connector with improved latch, cage type contacts, \\"solder stop\\" for easy soldering, and additional ground contact for best contact integrity between chassis and cable connector. More durable housing for maximum reliability. |
| 171 | SITC of DMX signal amplifier for improving/amplifying the input signals through longer distances. |
| 172 | SITC of DMX isolator or splitter provides Isolated optical DMX splitter provides 8 outputs from a 1 input and Input voltage: AC 110 to 220 V, 50 Hz, Product features: Group 1 & group 8 DMX signal change. |
| 173 | SITC of 5 pin XLR Male connectors having 5 pole cable connector, Male/Female connector with improved latch, cage type contacts, \\"solder stop\\" for easy soldering, and additional ground contact for best contact integrity between chassis and cable connector. More durable housing for maximum reliability. |
| 174 | SITC of Power Main Distribution Board made up of MS Sheet metal fabricated housing black powder coated and ivery connectors for the internal terminations and external outgoing connecting points, fibre / brass glands of suitable size fitted MCB control for outgoing circuits. Timer with required contactor for auto switching. Power panel suitable for indoor/outdoor applicable and floor mount / wall mount options.- 8 Nos of 32A TPN MCB Outgoing MCB's.- 1No of 100A TPN Incoming MCB. |
| 175 | SITC of Sub Power Distribution Board made up of MS Sheet metal fabricated housing black powder coated and ivery connectors for the internal terminations and external outgoing connecting points, fibre / brass glands of suitable size fitted MCB control for outgoing circuits. Timer with required contactor for auto switching. Power panel suitable for indoor/outdoor applicable and floor mount / wall mount options.- 12 Nos of 6/10A SP Outgoing MCB's.- 1No of 32A TPN Incoming MCB. |
| 176 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/coke and salt) as required |
| 177 | SITC of Din Rail Mount DMX controller can be used to control a wide variety of different DMX systems- from RGB/RGBW to more advanced moving and color mixing luminaires, DMX audio players and fountains. The controller comes with a variety of features, iPhone/iPad/Android remote control, Wi-Fi facilities, dry contact port triggering and flash memory.USB connection • 1024 DmX channels universe in live mode (computer) • 8 dry contact trigger ports via HE10 connector • stand alone mode with 5 area and 90+ scenes, Mac OSx 10.6/10.7/10.8 - Windows XP/VISTA/SEVEN/8 32/64 bits and USB 2.0, XLR3, mini USB, 1 HE10, Power From 5V to 5.5V DC (AC/DC adapter in option. |
| 178 | Earth Excavation Work for cable laying. |
| 179 | SITC of Programming Charges |
| 180 | SITC of Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears. |
| 181 | SITC of 9W Mono color Spot light, Protection Rating : IP66, complying to BIS standard \\"IS 10322 (Part 5/Sec 1): 2012\\" and having CE certification against standard \\"Low Voltage Directive & Protective Equipment - EN 60598-1:2015\\", and \\"Electromagnetic Compatibility Directive - EN 61547: 2009\\", Mounting Structure : Adjustable wall mount yoke arrangements for fixing the lights. Power consumption : 09W, CCT : 1800/3000/4000/6000K,(as per the design approval) Optics : PMMA with holder, Beam Angle : 15º/25º/45º/60º, Control : ON/OFF, Body : Die casted / extruded aluminium with embossed manufacturer logo, Hot spot and light distribution : Optics Designed to minimize hot spots & fringing in color mixing applications. Power Input : AC 110-230V, Surge Protection : Inbuilt surge protection 2KV-4KV(Additional if required will be added as per the requirement), Toughened transparent glass having the IK protection up to IK05, Painting : Chemical 3/7 tank processed treatment before the powder coat black/ash/approved color coat. Fixture will be suitable to operate in a temperature range of 0°C to 50°C, LED life should be at least 50,000 burning hours at L70 at 25 degree centigrade. Luminaire is inclusive of Integral male/female waterproof connectors with structures in pre wired conditions as per IS standard. PCB thickness must be 1.6mm, 35 micron Copper, 2W TC with Black or White masking, Copper /OSP finish. LM79, IK05, IP66, HV Certificates from NABL Acrediated laboratory. LED Makes should be CREE, LumilLED, Osram, Seoul, Nichia or equivalent with the engineer or 3rd party testing laboratory approval. |
| 182 | SITC of GI Cage for light protection, GI Cage made of mesh with back openable door and suitable hinges, light fixing provision with bolting option, base concrete foundation. |
| 183 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4C X 16 Sq.mm |
| 184 | SITC of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switchboard complete. The instrument chamber shall be separate and shall comprise a Multifunction meter and current transformer etc. The board shall have suitable capacity electrolytic aluminum bus bars as per IS:8623 insulated with heat shrink sleeving and mounted on non-hygroscopic supports such as CMC /DMC supports with detachable side covers and shall be suitable for an extension on the sides. The switches shall be complete with cable and boxes, pedestal-type cable socket compression glands and indicating lamps on incoming etc. The Power panel shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm with the following incoming and outgoings INCOMING MCCB-150Amp TPN-01 Multifunction meter-01 RYB Indicators-01Set, OUTGOING 63 Amp TPN MCB- 04 No, 10Amp SP MCB - 6Nos. |
| 185 | SITC of sub Power Distribution Board made up of MS Sheet metal fabricated housing black powder coated and ivery connectors for the internal terminations and external outgoing connecting points, fibre / brass glands of suitable size fitted MCB control for outgoing circuits. Timer with required contactor for auto switching. Power panel suitable for indoor/outdoor applicable and floor mount / wall mount options.- 22 Nos of 6/10A SP Outgoing MCB's. - 1No of 63A TPN Incoming MCB. |
| 186 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt) as required. |
| 187 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4C X 16 Sq.mm |
| 188 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/coke and salt) as required |
| 189 | SITC of Programming Charges |
| 190 | Supply, Installation, Testing & Commissioning of - Double Arm7000mm pole made of circular mild steel pipe of two section (grade YST 210), Bottom section 139.7mm Dia x 3.6mm thick with 1607mm Height & Top section 114.3mm Dia x 3.2mm thick with 1858mm Height. Decorative base made of Gravity Die-cast aluminium (504mm Dia x 1324mm Height). Decorative die cast aluminium cone (230mm Dia x 150mm Height) covered on the both section joint area. The double arm pelican orna eva bracket is a split constructed type, Bracket stem made of MS pipe 60.3mm Dia x 2.6mm thick, emerging from a split collar upto a height 1379mm crowned at the top with a decorative eva made of gravity die cast aluminium in single piece of 682mm height. The artistically curved double arm made of MS Pipe 38.1mm x 2mm thick, spruced up with MS Scroll with gravity die cast aluminium leaf and MS floral embellishment, is firmly held to the stem by way of cast iron clamps and the arm bears cast iron knobs at one end and other end facilitates the fitment of pendant luminaire at 890mm on either sides from the vertical axis of the bracket stem. Pole section welded by certified welders using high end MIG welding processes. PDC aluminium service door 348mm height x 110mm width shall be provided with the company logo embossed on the bottom of the door and safety rope. The control gear tray is prewired with 2.5 Sq.mm cable, 6A SP MCB and 32A Ramanuj stud type 4 way terminal block for loop-in / loop-out arrangement, 5A 2 Way terminal connector and provision for earthing. Any other internal cables and connections shall not be covered in the scope of supply. Mild steel mounting plate 300mm Square x 16mm thick Steel of grade E250 to IS 2062 : 2011 with 4 elongated holes 48 x 24 to suit M20 x 500mm bolts of grade 4.6 at CC 215. The base plate have a cable entry hole as per the base pipe size. This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation. All dimension are within +/- 5% tolerance. The pole is coated with zinc rich primer & pure polyester powder coating or epoxy zinc phosphate primer and finished using environmentally stable polyurethane based paint (coating thickness 60- 80 microns). The Pole shall be provided with Graphite grey / Anthracite grey / Black as standard colour options. |
| 191 | Supply, Installation, Testing & Commissioning of Input power : 90W LED Technical Description Pendant mounted compact street light. Type IV (Asymmetrical light distribution). Luminaire made of specially contoured spun aluminium body of high corrosion resistance with a neck design for unique and better aesthetics and non corrosive stainless steel fasteners. Clear acrylic / Clear polycarbonate diffuser. The luminaire have extruded aluminium heatsink for thermal management with vertical fin design for longer life of the LEDs. The mounting arrangement nipple, coupling & Hex nut made of Stainless steel 304 suitable for mounting to internally threaded pipe of designation M30. Protection class IP65. Mechanical resistance IK05 (Acrylic diffuser) & IK09 (Polycarbonate diffuser). Pure polyester powder coated graphite grey / anthracite grey / jet black. Available colour temperature 3000K / 4000K / 5700K, Colour rendering index (CRI)>70. K-Lite LED module with expected service life of at least 72,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >85%, Power factor >0.95, THD <10%, Surge protection 6KV. Luminaire dimension : 634mm diameter x 618mm height / 634mm diameter x 676mm height. CE & BIS Certified. Inhouse NABL accredited lab. |
| 192 | Supply & Installation of 3Phase ,15KVA outdoor type CCMS Panel equipped with 1 No Street Light Controller, 1 no Energy meter,1 no TPN MCB, 3 Nos 3 Pole contactors, 3 Nos 1Pole MCB’s, Battery, SMPS, 3 Nos Current Transformers & Toggle switches |
| 193 | Supplying and fixing of sheet steel enclosure on surface/recessalong with 25Amps,Double Pole ,240V,10KA, C Curve MCB complete with connections testing & commissioning as required |
| 194 | Supply of 2C X 4sqmm copper armoured cable |
| 195 | Laying of 2Cx4sqmm Copper Armoured Cable |
| 196 | Aluminium Armoured Cable |
| 197 | 4 x 16 sq. mm Aluminium Armoured Cable |
| 198 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 199 | Providing, laying and 80 mm dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. DSR No |
| 200 | Supply & ;laying of 63mm Dia DWC HDPE pipe ISIS marked along with all accessories like socket,bend,couplers etc.conorming to IS 14930 part II complete with fitting and cutting ,joining,etc.direct in gorund (75cm below ground leve;) inclsuing excavation and refilling the trench but excluding sand cushioning and protective covering etc,complete as required. |
| 201 | Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification.4 X 10 sq. mm (25 mm) |
| 202 | Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification.4 X 16 sq. mm (28 mm) |
| 203 | Supplying and making straight through joint with heat shrinkable joint kit including aluminium ferrules for following size of FRLS PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as per specification. 4 X 16 sq. mm |
| 204 | SITC of wall/free standing floor mounted dust and vermin proof compartmentalised cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear (c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar(>125 amp). |
| 205 | INCOMER 4P MCCB, 200A as out going 36KA |
| 206 | INCOMER Metering & Indication 1 set of phase indicating lamps (RED/YELLOW/BLUE) |
| 207 | INCOMER 200/5A CT |
| 208 | INCOMER 0-200 amps ammeter Analog |
| 209 | INCOMER 0-500 amps voltmter Analog |
| 210 | INCOMER selector switch for voltmeter |
| 211 | INCOMER selector switch for ammeter |
| 212 | BUS-BAR 1 Set of 200A 4P Aluminium Bus Bar with colour coded PVC Sleeves (4x800mm) |
| 213 | OUTGOINGS 4P MCCB, 63A 25KA adjustable overload,adjustable S/C setting Ics=Icu |
| 214 | Feeder Pillar:-1 SITC of wall/free standing floor mounted dust and vermin proof compartmentalised cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear (c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar(>125 amp). |
| 215 | INCOMER 4P MCCB, 63A 25KA adjustable overload,adjustable S/C setting Ics=Icu |
| 216 | 63A FP Contactor, |
| 217 | Metering & Indication 1 set of phase indicating lamps |
| 218 | 63/5A CT |
| 219 | 0-100 amps ammeter Analog |
| 220 | 0-500 amps voltmter Analog |
| 221 | selector switch for voltmeter |
| 222 | selector switch for ammeter |
| 223 | Outdoor LED Advertising screen , Working Temprature -20 to 50 deg C. |
| 224 | Supplying of Outdoor horn Speaker for Public Broadcasting System Waterproof complete as required. 30w |
| 225 | Supplying and drawing of speaker cable Single pair, 2-core, 1.5 sqmm cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit including connections and interconnections etc |
| 226 | Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. |
| 227 | Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required.100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set.Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set.Amplifier change over switch for inter changing amplifier- 1 No.Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch -1 No.Mains ON/OFF switch, fuse indication lamps, DC and AC.voltmeters & ammeters terminal blocks etc. complete as required -1 set.Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt,30 AH each sealed maintenance free batteries -1 set |
| 228 | supply ,Installation of digital audio amplifier 75W,25V rms operating voltage 240V AC as completed |
| 229 | OUTGOINGS 32A FP MCB, C Curve |
| 230 | OUTGOINGS 10A SP MCB |
| 231 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 232 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nutbolt & spring washer spaced at 50mm) |
| 233 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 234 | Supply and installing of 300x50x1.6mm perforated Hot Galvansised Iron cable tray with inconvenient sections with GI Bolt ,Nuts as required |
| 235 | Supply and installing of 300x50x1.6mm perforated Hot Galvansised Iron cable tray bend with GI Bolt ,Nuts as required |
| 236 | Supply and installing of 300x50x1.6mm perforated Hot Galvansised Iron cable tray TEEincovenient sections with GI Bolt ,Nuts as required |
| 237 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 238 | Supply of 4C X 6SQ mm AL Armoured Cable |
| 239 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm) |
| 240 | Supply, Installation, Testing & Commissioning of Black JBL IRX 108BT Portable Powered PA Speaker, 1300 Watt: Authentic 8-inch JBL woofer Four real-world EQ presets take the guesswork out of optimizing sound.dbx AFS Automatic Feedback Suppression stops feedback before it starts. Bluetooth integration allows stereo streaming of music, soundtracks and backing tracks.One-touch ducking automatically lowers music volume when speech input is detected. Wide frequency response: 54 Hz – 20 kHz Sensitivity (SPL): 124 dB Lightweight design: <22 lbs Wattage: 1,300W 2 XLR/TRS combo input jacks and 1 XLR out offer a range of connectivity choices. Mic/Line selection switch enhances versatility Durable honeycomb steel grille is road-tested for reliability. Built-in pole mount expands system set-up options. |
| 241 | Supply, Installation, Testing & Commissioning of 4 Bus Mixer for Live Sound and Recording 32 mono channels 2 dual stereo inputs with 4-band EQ Neutrik mic XLR Neutrik 1/4 inch jacksChannel insert Super wide gain ‘DuoPre’ mic line input 4-band EQ with 2 swept mids and in/out switch Illuminated mute Sound image pan Illuminated PFL & peak warning indicator ALPS 100mm faders 6 auxiliary sends (2 pre, 2 posts, 2 pre/post) 4 subgroups fed from each channel All inputs with level control 12 bar meters L, R, and M main mix outputs 2 matrix sections are available; can send output to USB Individual channel 48V phantom power Direct output on every mono channel Peak and signal indication on every channel Configurable USB stereo audio in/out Master-level controls on all outputs |
| 242 | Supply, Installation, Testing & Commissioning of XTi 6002Two-channel, 2100W @ 4Ω Power Amplifier:Features:Peakx Plus™ Limiters provide the ultimate in system performance and protection by allowing full control over threshold, attack, and release Enhanced Subharmonic Synth section provides user control over frequency, gain and filter type for system-specific tuning 3 User-defined fan mode controls – normal, early and fullspeed – for matching fan performance to a specific application New system monitoring provides software visibility of AC line voltage and power supply temperature Integrated cast-aluminum handles for easy handling and enhanced durability Locking power cord clip provides a secure connection between the amplifier and power cord Updated HiQnet System Architect™ control software Increased number of presets to a total of 50; 49 of which are user definable |
| 243 | Supply, Installation, Testing & Commissioning of Speaker Cables, CCTV, 1 pair 18 AWG (1 sq.mm). TC twisted speaker cable. |
| 244 | Supply, Installation, Testing & Commissioning of For Outdoor Wall Mounted LED Display Screen= 10'x6' |
| 245 | Supply, Installation, Testing & Commissioning 4 mm montana pole made of cast iron (ASTM A48 grade class-25). Decorative base made of cast iron (380mm Square x 1565mm Height). Continuously tappered decorative flutted pipe made of cast iron(126 Bottom Dia & 86 Top Dia x 1886mm height) fitted on cast iron base. Decorative cast iron floral embellishment (370mm height) for mounting pole top luminaires. Refer design in drgs or as approved from Engineer-in-charge. Pole section welded by certifiedwelders using high end MIG welding processes. PDC aluminium inner service door 348mm height x 110mm width shall be provided with the company logo embossed on the bottom of the door and safety rope. The control gear tray is prewired with 2.5 Sq.mm cable, 6A SP MCB and 32A Ramanuj stud type 4 way terminal block for loop-in / loop-out arrangement, 5A 2 Way terminal connector and provision for earthing. Any other internal cables and connections shall not be covered in the scope of supply. Mild steel mounting plate 200mm Square x 12mm thick Steel of grade E250 to IS 2062 : 2011 with 4 elongated holes 38 x 19 to suit M16 x 500mm bolts of grade 4.6 at CC140. This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm groutingninto the specially designed foundation. All dimension within +/- 5% tolerance. After fabrication, entire pole is shot blasted (Inhouse). The pole is coated with pure polyester powder coating or epoxy zinc phosphate primer and finished using environmentally stable polyurethane based paint (coating thickness 60-80 microns). The Pole shall be provided with Graphite grey / Anthracite grey / Black as standard colour options. |
| 246 | Supply, Installation, Testing & Commissioning of 50W Post Top Ring Fort Arc Mini Luminaire with 3000K/4000K Colour Temperature. The luminaire should be inverted mounted with symmetrical light distribution. Luminaire made of specially contoured spun aluminium body ( Ø425x1.6mm thickness). of high corrosion resistance and non corrosive stainless steel fasteners. Clear acrylic / polycarbonate diffuser.. Mild steel galvanized plating supporting arm. Gravity die-cast aluminium base suitable for mounting Ø50mm OD pipe. Protection class IP65. Mechanical resistance IK08, Colour rendering index (CRI)>70. SDCM-3 MacAdam. K-Lite LED module with expected, service life of at least 60,000 operating hours at 40°C. Operating ambient temperature range is from -15°C to+50°C. Driver efficiency >85%, power factor >0.9, THD <10%, In-Built Surge protection 4KV. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire dimension should not be greater than Ø425 and height 628 mm.Manufacturer must have inhouse NABL certified lab equipped with photo goniometer, IP, IK test facilities. Manufacturer must submit LM79,LM80 reports. The luminaire should be CE & BIS Certified. |
| 247 | Supply ,Instalation ,Testing & commissioning of 200KVA,11KV/433V Transformer with 11KV AB Switch, 11KV HG Fuse Set, Metering with CT's , construction of Plinth with required materials. With LT APFC Panel,HT Cabling, TVSS, Substation Earthing,Bustrunking from Transformer to LT panels,SPD,etc |
| 248 | Supply ,Instalation ,Testing & commissioning of 200KVA ,415V,50HZ silent type DG set, AMF panel, bus ducting/cables from DG to panel. DG set enclosure sound insulation/ ventilation /smoke exhaust. Earthing, civil foundation. DG set exhaust piping/chimney as CPCB norms |
| 249 | Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure die cast aluminum housing LM6/ADC12 material, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps. Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85% and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficiency >=120 lm/ watt with High Power LEDs is to be used. LED driver Input Voltage AC120 V to 270 V AC with High voltage Cut off@>=300V AC and Auto resetting Safety. Input Frequency 50Hz+3%, Power Factor>0.95, driver Efficiency >85%,THD(1) <10%, driver current 1000 mA. High Power LED Flood Light 300W. |
| 250 | Supply installation testing & Commissioning 25M (in 3 section) high mast lighting system (as per PLG 07of ILP UK techinical report no7 of ILEUK/IS:875 Part-1-2015 /BSEN10025/andIS:2062)consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for upto 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstruction lights,double drum type self sustaining winch, integral power tool accessible from door with padlocking arrangement (winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening final, S.S.ropes (AISI316,7/19 construction), EPR insulated PCP sheathed trailing cable, including outdoor type control panel for auto on/off, reverse / forward motor operation and CC foundation of M - 25 grade complete as required as per IS 456/IS 2911. |
| 251 | Direction and Place Identification Signs upto 0.9 sqm Size Board. Providing and erecting direction and place identification retroreflectorised sign as per IRC :67 made of Type XI retro- reflective sheeting, vide clause 801.3, fixed over Aluminium composite material sheet with overall thickness of 4mm with area not exceeding 0.9 sqm fixed over back support frame of min 35 x 35 x 3mm Angle mounted on a mild steel circular pipe 65 NB, firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing. |
| 252 | Direction and Place Identification Signs with size more than 0.9 sqm size Board.Providing and erecting direction and place identification retroreflectorised sign as per IRC :67 made of Type XI retro- reflective sheeting, vide clause 801.3, fixed over Aluminium composite material sheet with overall thickness of 4 mm with area exceeding 0.9 sqm fixed over back support frame of min 40 x 40 x 5 mm MS Angle mounted on two nos. of mild steel circular pipe 65 NB, 3.2 mm thickness and 4.5 meter total height firmly fixed to the ground by means of properly designed foundation with M 25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. |
| 253 | Retro-Reflective Traffic Signs with Type XI retro- reflective Sheet:Providing and fixing of retro reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of Type XI retro reflective sheeting fixed over 3mm/4mm thick Aluminium composite material sheet vide clause 801.3, depending on the size of the sign fixed over back support frame of min 25 x 25 x 3mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67. 600 mm equilateral triangle |
| 254 | Retro-Reflective Traffic Signs with Type XI retro- reflective Sheet:Providing and fixing of retro reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of Type XI retro reflective sheeting fixed over 3mm/4mm thick Aluminium composite material sheet vide clause 801.3, depending on the size of the sign fixed over back support frame of min 25 x 25 x 3mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67. 900mm high Octagon |
| 255 | Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with p modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Group A |
| 256 | Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with p modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Group B |
| 257 | Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with p modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Group C |
| 258 | Wiring for light I power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface I recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable fo r loop earthing as required .(7x1.5sqmm.) |
| 259 | Wiring for circuit/ subn1ain wiring alongwith earth wire vvith the follovving sizes of FRLS PVC insu lated copper conductor, single core cable in surface/ recessed steel conduit as required.(8x1.5sqmm.) |
| 260 | Wiring for light I power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface I recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable fo r loop earthing as required .(7x1.5sqmm.) |
| 261 | Wiring for light I power plug with 2X4 sq . mm FRLS PVC insulated copper conductor single core cable in surface I recessed ~tee ! conduit alongwith 1 No. 4 sq . mm FRLS PVC insulated copper conductor s ingle core cable for loop eaithing as required .(6x1.5sqmm.) |
| 262 | Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2 X 1.5 sq. mm +1x1.5 sqmm earth wire |
| 263 | Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2X 2.5 sq. mm +1x2.5 sqmm earth wire |
| 264 | Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2 X 4 sq. mm +1x4sqmm earth wire |
| 265 | Supplying and fixing on surface/ recess following way, 240 volts SP&N MCB distribution board of sheet steel phosphatized and powder painted complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator).8 way, Single door |
| 266 | Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification.5 amps to 32 amps |
| 267 | Providing & Fixing of IP20S MD Mid Power LED batten type integrated light fixture made from polycarbonate/ extruded aluminum powder coated housing with in built driver, Power Consumption of 18W/20W, system lumen efficacy≥ 120 lm/Watt output,internal surge protection of 2.5KV with Short & Open circuit protection,THD<10%, p.f≥0.95, CRI>80, life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trademark certificate (T.C.).4' LED Tube shape fixture 18/20watt, extruded aluminium base |
| 268 | Providing & Fixing of IP20S MD Mid Power LED batten type integrated light fixture made from polycarbonate/ extruded aluminum powder coated housing with in built driver, Power Consumption of 18W/20W, system lumen efficacy≥ 120 lm/Watt output,internal surge protection of 2.5KV with Short & Open circuit protection,THD<10%, p.f≥0.95, CRI>80, life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trademark certificate (T.C.) 10 watt {2 feet} - Poly Carbonate base |
| 269 | laying of one number FRLS PVC insulated , PVC sheathed, steel armoured, 2x10sqmm aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 9537 (2000, Part 5). . |
| 270 | Supply of 2 x 10 sq. mm Al Armoured cable |
| 271 | Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. . 2 X 10 sq. mm (19 mm) |
| 272 | Supply & laying of DWC HDPE pipe ISIS marked along with all accessories like socket,bend,couplers etc.conorming to IS 14930 part II complete with fitting and cutting ,joining,etc.direct in gorund (75cm below ground leve;) inclsuing excavation and refilling the trench but excluding sand cushioning and protective covering etc,complete as required. 63mm Dia Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail