| 1 | [11.69.2]Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. 2. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre [Through Rate] |
| 2 | [11.78]Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. [Through Rate] |
| 3 | [13.27]Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. [Through Rate] |
| 4 | [13.32]Providing and fixing bolts including nuts and washers complete. [Through Rate] |
| 5 | [23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA [Through Rate] |
| 6 | [23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate] |
| 7 | [23.24.3.2]MS STAND, BUS BAR CHAMBER AND PANELS 3.2. Supply and erection of metal clad bus bar chamber made from 1.6 mm thick M.S. sheet and fixing with rag bolts on wall or on existing pedestal/angle iron frame including bonding, detachable top and bottom including painting and necessary connection etc. (Aluminium bars). 100 amp 4 bars of 55 cm each (cross section 25 mm x6 mm) chamber over all size 60 cm x 45 cm x 18cm [Through Rate] |
| 8 | [23.26.2]SAFETY ITEMS 2. Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages. [Through Rate] |
| 9 | [23.27.3]Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 3. M.S. pedestal of size 750 mm wide , 1200 mm high ,300 mm deep and bottom totally open , duly embeded in cement concrete block of size 900 mm x 450 mm x 200 mm above ground level , having a base of size 1050 mm x 600 mm x 250 mm below ground level . 0 0 [Through Rate] |
| 10 | [23.6.6.4]MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.4. Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS pipe of 40 mm dia. [Through Rate] |
| 11 | [24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate] |
| 12 | [24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate] |
| 13 | [24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate] |
| 14 | [24.2.1]LT CABLE 1. Supply & erection of LT phase separator on LT line complete in all respect up to entire satisfaction of the Engineer-in-charge of the work. [Through Rate] |
| 15 | [24.2.8.14]LT CABLE 8.14. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work.300 sqmm [Through Rate] |
| 16 | [24.2.8.9]LT CABLE 8.9. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 95 sqmm [Through Rate] |
| 17 | [24.3.4.2]HT CABLE 4.2. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 150 to 185 sqmm [Through Rate] |
| 18 | [24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia [Through Rate] |
| 19 | [34.3.2]Printing New Letter and Figures of any ShadePrinting new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade 2. English and Roman (Hyphens not to be paid) [Through Rate] |
| 20 | Supply and erection of PCC pole as per IS: 1678-1960 specifications, 11Mtr. long 140mm x 200mm at top and 140mm x 400mm at bottom with working load of 400Kg buried 2.20M in ground or as per UHBVNL specification . |
| 21 | Supply and erection of PCC pole as per IS: 1678-1960 specifications, 9 Mtr. long 105mm x 115mm at top and 105mm x 315mm at bottom with working load of 200 Kg. buried 1.80m in ground or as per UHBVNL specification. |
| 22 | Supply and erection of wooden cleats of size 4” wide and 1’-6” long complete with 4 Nos. holes suitable to pass through 300/400sqmm single core cable complete in all respect up to the entire satisfaction of Engineer-in-charge |
| 23 | Supply and erection of cradle guards made of 8 S.W.G. confirming to ISS 280/1978/1973 with latest amendments complete in all respect up to the entire satisfaction of Engineer-in-Charge. For HT Line |
| 24 | Supply and Erection of shackle insulator brown glazed (90 mm x 75 mm) Tape-I suitable for 415 /240 Volt confirming to IS 1545/1977 with latest amendment thereof |
| 25 | Supply and Erection of M.S. D-strap type-I made out of M.S Flat of size 40 x 6mm suitable for LT insulator 90 x75mm with latest amendments complete in all respect up to the entire satisfaction of Engineer-In-Charge. |
| 26 | Supply and erection of 11 KV lighting arrestor as per relevant ISS specification |
| 27 | Supply and erection of stay set for LT/HT Line complete in all respect with G.I. stay wire( rope of 7 wires of 8 SWG G.I. Wire), egg/Disc insulator , G.I. rod of 20mm dia 8’ long threaded up-to 250mm long with nut (weight 6.224 kg) with cross plate of 460mm of angle 65x65x6 mm(weight 5.33 kg), elbow (weight 2.24 kg ) complete with clamps , nuts and bolts complete in all respect up-to the entire satisfaction to Engineer-in-Charge of the work.LT Stay |
| 28 | Supply and erection of stay set for LT/HT Line complete in all respect with G.I. stay wire( rope of 7 wires of 8 SWG G.I. Wire), egg/Disc insulator , G.I. rod of 20mm dia 8’ long threaded up-to 250mm long with nut (weight 6.224 kg) with cross plate of 460mm of angle 65x65x6 mm(weight 5.33 kg), elbow (weight 2.24 kg ) complete with clamps , nuts and bolts complete in all respect up-to the entire satisfaction to Engineer-in-Charge of the work.HT Stay |
| 29 | Supply and erection of 11 KV brown glazed 10 KN pin insulator with GI pin/ silicon type as per specification and approved make by DHBVN. |
| 30 | Supply and erection of V-shape X-arm suitable for 11KV system made of out of 1650mm long MS channel of size 100x50x50x6mm as per design and drawing 2 Nos. 18mm dia holes provided in the base for fixing of half clamp made of MS flat of size 50x6mm and 2 Nos. holes 22mm dia for GI Pin on the flange plate of MS Flat of size 50x6mm shall be provided on the top and bottom flanges of both end of V-shape X-arm with 22mm hole in the plate complete in all respect including primer and aluminum paint. |
| 31 | Supply and erection of top hamper suitable for 11 Mtr. long PCC pole and 11KV system made out of MS flat size 50x6mm (A shapes) having approx weight 2.5 kg as per approved design and drawing including primer and alum paint complete all respect. |
| 32 | Supply and erection of fuse unit of L.T. side suitable for 200 KVA transformer complete with wooden board cleats, aluminum strips MS clamps and MS nut and bolts including all petty material required up-to the entire satisfaction of Engineer-in-Charge. |
| 33 | Supply and erection of ACSR conductor conforming to IS 398 (Part-II) 1976/1996, IS 4826-1976 IS 1521-1972 and IS 1778-1980 with latest amendments and erection of the same with accessories including stringing and sagging of conductor of various sizes i.e. 100mm2/80mm2/50mm2/30mm2/30mm2 PVC insulated as well as jointing and binding with insulator at supports in all respect up to the entire satisfaction of Engineer-in-Charge.100sqmm ACSR |
| 34 | Supply and erection of ACSR conductor conforming to IS 398 (Part-II) 1976/1996, IS 4826-1976 IS 1521-1972 and IS 1778-1980 with latest amendments and erection of the same with accessories including stringing and sagging of conductor of various sizes i.e. 100mm2/80mm2/50mm2/30mm2/30mm2 PVC insulated as well as jointing and binding with insulator at supports in all respect up to the entire satisfaction of Engineer-in-Charge.80 Sqmm ACSR |
| 35 | Supply and erection of ACSR conductor conforming to IS 398 (Part-II) 1976/1996, IS 4826-1976 IS 1521-1972 and IS 1778-1980 with latest amendments and erection of the same with accessories including stringing and sagging of conductor of various sizes i.e. 100mm2/80mm2/50mm2/30mm2/30mm2 PVC insulated as well as jointing and binding with insulator at supports in all respect up to the entire satisfaction of Engineer-in-Charge.30 Sqmm PVC Insulated ACSR Condt. |
| 36 | Supply and erection of anti climbing barbed wire of size 12x12 gauge (6.33 Mtr. = 1.00 kg) for 11 KV/33KV Poles complete in all respect |
| 37 | Supply and erection of L.T. Aerial bunched cable of size 120 Sqmm, 4 core plus 95 Sqmm including making of necessary connection of make Polycab, Havell’s Grandlay, complete in all respect up to the entire satisfaction of Engineer-in-charge |
| 38 | Supply and erection of Disc insulator with fitting on PCC pole of approved make of State Electricity Nigam requirement to complete in all respect to confirming to ISS 731/1971 latest amendment thereto. |
| 39 | Supply and erection of PVC insulated sheathed 50 Sqmm aluminum conductor cable single core 1100 volts grade in existing pipe, complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. |
| 40 | Supply and erection of P.G clamp Al cast 2 bolt suitable for 50/80/100 Sqmm ACSR conductor complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. |
| 41 | Supply, installation, testing, commissioning of 3 Phase 11KV/0.433 KV-250V, 200 KVA Oil immersed, naturally cooled, Aluminum Wound Outdoor type Distribution Transformers with CSP (Completely self protected) features with external micro-processor based four pole MCCB 300Amp. To 400 Amp, 50kA strictly conforming to Nigam’s technical specification No. CSC-V/R-I/DH/UH/P and D/2010-2011 read with amendment thereof and as per relevant ISS as amended from time to time and losses conforming to 4 stars rating of BEE as per Approved Specification of DHBVN/UHBVN including installation of transformer on existing platform up-to the entire satisfaction of Engineer-in-Charge.Voltage Rated Frequency Permitted at 75ºCi) Maximum load looses at 50% load at 75ºC = 780 Watt ii) Maximum losses at 100% load at 75ºC = 2300 Wattiii) Warranty = 78/72 Months shall be one time The above losses are maximum allowable and there would not be any positive tolerance. |
| 42 | Supply and erection of Prodigy type in-built L.T. C.T. meter of (40- 200 amps), 3-phase 415 Volts rating suitable for 3-phase, 4-wire system of make Secure, Genus or other make approved by the UHBVNL. The meter is to be fixed in M.S Sheet cubical meter box on existing PCC Pole. This includes all petty material i.e. M-Seal, Nut–Bolts, thimbles etc. Meter will be got tested from the UHBVNL lab by the contractor after depositing the meter testing fee by him and it will be refunded on production of receipt received from UHBVNL. |
| 43 | Supply, erection, testing and commissioning of ELEX-TWS-2EXT / Amson’s/LandT make Automatic electric timer to switch ON/OFF the street light automatically. It should have adjustable lux level switch, with extensible mountable sensor. It shall change ON/OFF timing automatically as per lux level of the Sun at sun-rising and sun setting, throughout the year. Shall have two Nos. LandT make, 3 pole power contactor model MNX-70 to control 70 amp per phase with 220 Volt coils. It shall have auto/manual switch for repair of street light during day time. The whole unit components to be assembled on Bakelite sheet with 16 amp capacity MCB to save the time switch. The erection of the complete unit in the existing pedestal with complete wiring upto the entire satisfaction of the Engineer-in-charge.ON/OFF Timer |
| 44 | Supply and erection of Suspension clamp Dead end clamps and eye belts for sagging of 11KV XLPE Aerial Bunched cable suitable for 50sqmm x 3 core to 240 sqmm x 3 Nos complete in al respect upto the entire satisfaction of Engineer-in-charge of the workSuspension clamp 50sqmm to 240 sqmm |
| 45 | Supply and erection of Suspension clamp Dead end clamps and eye belts for sagging of 11KV XLPE Aerial Bunched cable suitable for 50sqmm x 3 core to 240 sqmm x 3 Nos complete in al respect upto the entire satisfaction of Engineer-in-charge of the workEye bolt 50sqmm to 240sqmm |
| 46 | Supply, stringing and sagging of 8 SWG G.I. earth wire as per complete in all respect to the entire satisfaction of Engineer-in-Charge conforming to IS 298/1978 and 7807/1973 and with latest amendment thereof. (Excluding GST) |
| 47 | Supply and erection of guards reel for LT line made of 8 S.W.G. G.I. wire complete in all respect up to the entire satisfaction of Engineer-in-Charge. |
| 48 | Supply and Erection of 11 kV G.O. Switch vertical mounted with heavy duty 9 Nos. post insulators suitable copper male and female contacts fixed on GI angle frame with G.I. Nut and Bolts including G.I. pipe and operating handle complete in all respect (Excluding GST). |
| 49 | S/E of cable holding clamp made out with two pieces of best quality of wood, suitable for HT 11 KV XLPE cable of size 185 sq mm x 3 core complete with cutting of wood of suitable size i.e size of one half clamp should be 50 mm width x300mm long x 100 mm high, complete with making grove of suitable size for cable 185 sqmm x 3 core complete with nut and bolt of suitable size and primer and paint complete in all respect. (Rate excluding GST) |
| 50 | Supply and erection of 63 Amps connection plate for incoming and outgoing cable in existing Panel/High Mast/Octagonal Pole etc. to be fitted with connector fixed on Bakelite sheet complete with nut and bolts. |
| 51 | S/E of 70/72 Watt LED street light luminaries with multiple LED with highly efficient high power LED light with lens, pressure die cast aluminum housing, reflector and enclosed with toughened glass/Polycarbonate, IP-66 level, having light efficacy 120 Lumens/watt up to the entire satisfaction of engineer-in-charge of work complete in all respect. Make:- Bajaj/Philips /LT (With 3 years free replacement warranty at site including labour charges free of cost). (Rate excluding GST) |
| 52 | Supply and erection of PVC insulated and sheathed underground cable, loose in existing pipe or trenches 1100 volts core having solid aluminium conductor wires confirming to IS: 694:2010, including making necessary connections complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. Cable Size: 16 Sqmm x 4-core (Armd.). Make: Grandlay/Polycab/Havell`s. (Without GST) |
| 53 | Supply and erection of PVC insulated 300 Sqmm single core un-armoured power cable with aluminum conductor 650/1100V confirming to ISS 1554(Part-I) of 1988 IS: 7098/Part-1/1988 with latest amendments with necessary connections and complete in all respect up-to the entire satisfaction of Engineer-in-Charge of the Work. Make: Grandlay/Polycab/Havell`s. (Excluding GST). |
| 54 | Supply and erection of 2.5 Sqmm x 3-core (Unarmd.) PVC insulated and sheathed Aluminium conductor service cable 1100 volts, having single solid aluminium conductor in each core as per IS:694, complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. Make: Polycab, Havell`s, Grandlay. (Excluding GST). |
| 55 | Supply and erection of 10 Sqmm single core copper, PVC insulated and unsheathed industrial multi strand cable, Flame Retardant Lead Free (FRLF) confirming to IS-694:2010 with bright annealed electrolytic bare copper conductor for voltage grade 1100 volts complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. Make: -Havell`s/Polycab/Grandlay. (Excluding GST) |
| 56 | Only Labour charges for ON/OFF operation of all type of LED Light points including Removal of Fault of Circuits. Dismantlement and re-erection of LED fitting from poles for replacement or repairing of LED lights under Defect Liability Period. (2nd Year DLP) |
| 57 | Only Labour charges for ON/OFF operation of all type of LED Light points including Removal of Fault of Circuits. Dismantlement and re-erection of LED fitting from poles for replacement or repairing of LED lights under Defect Liability Period. (3rd Year DLP). |
| 58 | Rate without GST for Supply and erection of 185 sqmm 3 core XLPE (E) 11 KV HT aluminum conductor armored cable armored cable ISI make laid in existing pipe/ trenchers/ surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer in charge of the work.Make:- Havell`s, Polycab, Grandly. (Excluding G.S.T.) |
| 59 | Supply and erection of G.I. pipe bracket 1.0 mtr. long made out of 32mm dia (B-class), suitable for street light fitting including 2 nos. clamps of M.S. flat size 50x6mm, 6 nos. Nutt and Bolts of size 50x16mm with application of primer and painting complete in all respect up to the entire satisfaction of Engineer-in-charge. (Excluding G.S.T.) Please Enable Macros to View BoQ information |