| 1 | Dismantling old or scerting racking out points and clearing the surface for plaster including disposal of Unserviceable of rubishto the dumoping ground with in 50 meters Leads.D.S.R.No.15.56 |
| 2 | 12 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) including cost of all material, labour, T&P etc. required for proper completion of work. DSR NO.13.4.2 |
| 3 | 12 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) including cost of all material, labour, T&P etc. required for proper completion of work. DSR No.13.4.1 |
| 4 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) nondecorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.DSR-9.21.1 |
| 5 | Providing and fixing fly proof galvanized M.S wire guage to windows and clerestory windows using wire guage with awerage width of aperature 1.4 mm in both directionswith wire of dia 0.63 mm all complete (a) DSR.NO.9.51.1 With 2nd class wood beading 62x19 mm |
| 6 | Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge . DSR NO. 15.45.1 |
| 7 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.DSR NO.15.3 |
| 8 | Removing White and colour wash by scrapping and sand papering and preapring the surface smooth including necessary repairs to scratches etc complete .DSR No. 13.88 |
| 9 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. DSR 13.80 |
| 10 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre DSR- 13.41 |
| 11 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm DSR- 13.48.1 |
| 12 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead For thickness of tiles above 25 mm and up to 40 mm DSR 15.23.2 |
| 13 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete DSR 11.38 |
| 14 | Providing and fixing 20mm Dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes DSR 18.8.2 |
| 15 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm dia nominal outer dia pipes DSR 18.8.3 |
| 16 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require. White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. DSR 17.7.1 |
| 17 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litre with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. DSR 17.81 |
| 18 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore. DSR 18.52.1 |
| 19 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 1)CP Bib cock 15mm dia DSR 18.50.1 |
| 20 | Brick work with common burnt clay (non modular) bricks of class-150 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) DSR. 6.1.2 |
| 21 | Providing and fixing white vitrius china water closet squatting pan (Indian type W.C. pan ) along with P or S trap,including dismentling of old W.C seat and \\"S\\"OR :P\\" TRAP at site complete with all operations including all necessary materials, labour and disposal of dismentaled material including malba all complete as per the Direction of Engineer in charge. DSR 14.80.1(Long pattern Type 580x440 mm DSR 14.80.2 |
| 22 | Providing and Fixing angle iron frames for doors, windows chaukhat and ventilators of mild steel Angle sections of size 35x35x5 mm,joints mitred and welded by angle iron 35x35x5 mm flats pieces to the existing T - Iron frame or to thewall with the dash fashner,includind fixing of necessary but hinges and screw and applying a priming coat of approved steel primer,all complete as per Direction of E/I Si No. chap 10 (10.31) |
| 23 | Renewing glass pans in doors, windows and ventilators etc. 4 mm thick fixed with putti etc. complete including cost of all labour material, T&P etc. DSR 14.5.1 |
| 24 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter. DSR 12.41.2 |
| 25 | P/F 60X45X5.5 MM Thick bevelled edge mirror of Superior Glass (Of approved Quality) Complete with 6 mm thick hard board ground fixed towooden cleats with CP Brass screws and washers complete DSR17.31 |
| 26 | Providing and Placing on terrace (at all floor level) polythene water storage tank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipe but without fittings and the brass support for Tank. DSR 18.48 |
| 27 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. ( BASED ON D.A.R. NO. 14.72 ) |
| 28 | Washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of Engineer-in-charge (payment for providing grooves shall be made separately). (apply on old work Only for washing ) DSR 13.72 Please Enable Macros to View BoQ information |