| 1 | Dismantelling of brick masonary. |
| 2 | Dismantling cement concrete in 1:8:16 mix with brick ballast. |
| 3 | Earthwork in Excavation in foundation/trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 mt depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation |
| 4 | Cement Concrete 1:4:8 with brick ballast 40mm gauge. |
| 5 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. |
| 6 | Cold twisted deformed(Ribbrd/ Tor Steel Bar) Fe 500 grade as per IS 1786-1985, for RCC works, where not including in the complete rate of RCC incl. bending, binding placing in position. |
| 7 | Reinforced Cement concrete M20 by mechanical means using concrete mixer volumetric type confirming IS1791 and vibrated with needle vibrator In Foundation & Plinth |
| 8 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 9 | Centering and Shuttering for faces of concrete columns |
| 10 | Centering and Shuttering for faces of concrete beam, launching apron etc. |
| 11 | First class burnt brick work laid in cement sand mortor 1:6 in first storey upto 4 metres above plinth level. |
| 12 | Cement Concrete 1:2:4 with stone ballast or shingle mixing by mechnical means using Concrete mixer volumetric type. |
| 13 | 20mm thick cement plaster 1:4 in two coats |
| 14 | 10 mm th cement paster 1:4 |
| 15 | Steel work, fixed independently without connecting plates including cutting ,hoisting and fixing in position ( tees, angle & channels) |
| 16 | Wrought iron & mild steel ladders, framed grills, grating etc with ends of bars riveted molded forged window guards, barred iron doors stair case iron railing etc . Including cost of bolts and nuts, screws, welding rod complete in position. |
| 17 | Drilling holes in girders |
| 18 | Finishing walls with cement based water soluble exterior paint such as snowcem, robbiacem etc. two or more coats to give an even shade |
| 19 | Providing and fixing pair of Plastic dustbins 100 litre volume each, of two different colours, for dry and wet waste, made of virgin plastic to be mounted on MS rectangular hollow section 50 x 25 x 3 mm frames pivoted on 3 MS square hollow section verticals, 1 m above ground, one 35 cm RHS welded to each vertical member at base and grouted in 180 x 40 x 30 cm 1:2:4 cement concrete. |
| 20 | Supply and installation of garden bench - Chair type garden bench with L-shaped sides made of reinforced concrete (M30), thickness 100 mm, overall height 1000 mm, base width 620 mm. Back and seat shall consist of 5 Nos. reinforced concrete planks 1500 mm x 100 mm x 50 mm one plank 1500 mm x 200 mm x 50 mm. Seating height of the bench shall be 450 mm. The bench shall be fixed with nuts on concrete mount, all holes sealed after assembly and installation |
| 21 | Providing and fixing of garden fencing of green hexagonal net. Fixing of fencing with MS angles 25 x 25 x 3 mm frame, vertical members 1.5 m above ground fixed 30 cm in ground at 2m with cement concrete 1:2:4. Net to be fixed with nut bolts and washers. |
| 22 | Providing cement pots at site of work, filling 2/3rd volume with mixture of good earth and screened manure and cocopeat in the ratio 2:1:1. |
| 23 | 35 cm size of pots |
| 24 | 50 cm size of pots |
| 25 | 60 cm size of pots |
| 26 | Supply and erection of 3-Stepped steel tubular swaged and welded pole (410-SP- Mpa) of Overall length 7 metre, with planting depth 1.25 metre, length of sections 4 metre, 1.5 metre and 1.5 metre (Bottom, Middle and Top respectively), Outer dia and thickness of sections 114.3mm x 4.5mm, 88.9mm x 4.05mm and 76.1mm x 3.25mm (Bottom, Middle and Top respectively) with approximate weight 73 kg. (410 SP-2) and base Plate weight 7.5 kg. of size 12mm thick about 30 cm dia. |
| 27 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- Overall size 10sq.mm (2Core) Armoured (Loose) |
| 28 | Led Flood Light 30 Watt |
| 29 | Supply and fixing barbed wire |
| 30 | Supply and fixing Precast walls with M-30 grade concrete |
| 31 | Any other Item Please Enable Macros to View BoQ information Compatibility Report for PBBoundariwall.xls Run on 14-03-2026 13:09 The following features in this workbook are not supported by earlier versions of Excel. These features may be lost or degraded when opening this workbook in an earlier version of Excel or if you save this workbook in an earlier file format. Significant loss of functionality # of occurrences Version Any effects on this object will be removed. Any text that overflows the boundaries of this graphic will appear clipped. 3.0 BoQ1'!A1:II47 Excel 97-2003 Minor loss of fidelity Some formulas in this workbook are linked to other workbooks that are closed. When these formulas are recalculated in earlier versions of Excel without opening the linked workbooks, characters beyond the 255-character limit cannot be returned. 5Defined Names Excel 97-2003 Some cells or styles in this workbook contain formatting that is not supported by the selected file format. These formats will be converted to the closest format available. 5.0 Excel 97-2003 |