| 1 | Electrical work |
| 2 | OD502986/2025-2026:Supply of 3 phase 415/430 V, 20 HP, 15 KW, open well submersible pump set with 65 mm pipe size, head range of 56 to 110mtr, discharge rate of 60000 to 24000 L/M (Makes preferred :- Deccan-20DV/5stage SPL IMPELLER or equivalent Texmo make) |
| 3 | OD502978/2025-2026: Supply and providing three phase submersible pump controller with ammeter, voltmeter, push button, contactors, Over load relay, single phase preventer, additional dry run protector (iAD) wire harness sets for iAD, control side and module side connections etc suitable for 30 HP submersible pump, including connections, setting and testing as required (L&T make MU-G30 FASD relay rage(30-50) H heavy duty FASD or equivalent make) |
| 4 | 90.14.24.21:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.6 KVAr, 3 phase, 440 V, delta connected, standard duty Metalised Poly Propylene Capacitor, Box Type, suitable for direct connection to motors. |
| 5 | OD502987/2025-2026:Supply and providing 16 mm size nylon marine rope (garwar/equivlent mkae) for hanging the pump set in well, tying with an out side object as required. |
| 6 | OD502995/2025-2026:Charges for the installation of above 20 hp 3 phase submersible pump set into the well after connecting the delivery pipes, with accessories and lead cables to motor and hanging the unit with nylon rope to 10 mtrs depth complete in trouble free operation and conducting trial run satisfactorly. |
| 7 | OD502993/2025-2026:OD326211/2024-2025Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100mm |
| 8 | OD502985/2025-2026:Supply,conveyance and erection of 65mm ISI marked Cast Iron flanged type Check Valve / Non Return valve as per IS: 5312 PN 1.6 with CI body , CI door with SS hinge pin, bronze seating ring , natural rubber door face and gaskets etc. and fixing the same in position using necessary rubber packing ,bolt nut and washer etc. |
| 9 | OD502998/2025-2026:Supply ,conveyance and erection of 65 mm ISI marked Cast Iron flanged type Rising spindle Sluice valve as per IS: 14846 PN 1.6 with CI body and SS spindle including wheel and fixing the same in position using necessary rubber packing ,bolt nut and washer etc. |
| 10 | OD502997/2025-2026:Supply and providing industrial type pressure gauge with gun metal / brass vales in position asrequired. |
| 11 | OD502988/2025-2026:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in theexisting MCB DB / enclosure, complete with connections, testing and commissioning etc. asrequired. 100 amps |
| 12 | OD502990/2025-2026:Supply and providing 4 pole enclosure for independent mounting of mcb/rccb/isolator etc required |
| 13 | OD502977/2025-2026:supply and installation of 440 v 100 A 4 POLE change over switch unit in steel enclosure complete with handle assembly door interlock etc on existing angle iron frame work or directly to wall using necessary bolts ; amp;nuts ,fixing the unit to wall making good the damage ,colour washing etc;including giving necessary connection as required |
| 14 | 90.6.10.3:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm |
| 15 | 90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm |
| 16 | 90.6.6.6:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.16 sq mm |
| 17 | 90.6.4.63:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.16.00 sq.mm 4 Run |
| 18 | 90.6.4.64:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.16.00 sq.mm 6 Run |
| 19 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 20 | OD502980/2025-2026:Supply and providing 8.mm thick MS checqured plate in the existing frame owrk etc asrequired. |
| 21 | 90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size |
| 22 | OD502992/2025-2026:supply and providing red yellow blue colour led indicator lamp ,AC/DC,25.5mm cutout dia as required |
| 23 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 24 | OD502984/2025-2026:Supply and providing Test joint for earthing made up of 2 nos, 25x5 mm GI strip, 25 cm long placed on either sides of earth leads and watering pipe, bending, drilling and tightening with 4 sets of brass/SS nut, bolt, washer etc as required. |
| 25 | 90.16.2.1:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class) |
| 26 | 90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) |
| 27 | 90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) |
| 28 | OD502983/2025-2026:Supply and providing 25X3 mm brass bolt and nut with washers on the existing MS box/earth bus etc as required including drilling necessary holes as required. |
| 29 | OD502991/2025-2026:Supply and providing 25X6 mm brass bolt and nut with washers on the existing MS box/earth bus etc as required including drilling necessary holes as required. |
| 30 | OD502982/2025-2026:Supply and providing dust and vermin proof, wall mounting, Hot press moulded SMC Meter Box of following sizes suitable for fixing KSEB meter, fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit, with 650x350x210 mm or nearest size. (Sintex GS-MB 6535 or equivalent make). |
| 31 | OD502989/2025-2026:supply and fixing 100 A backelite HRC fuse unit with HRC fuse link in the existing meter board and giving connections as required |
| 32 | OD502996/2025-2026:Supply and fixing the following accessories in the existing board and giving connections etc. 100A 2 way Neutral link mounted on DMC/ SMC base |
| 33 | 14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. |
| 34 | 14.11:Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels. |
| 35 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels |
| 36 | OD502981/2025-2026:Supply fabrication conveyance and installation of MS truss work using ISMB 150*75 and 40*40*5mm angle iron etc.as per given drawing ,fixing it on open well ,including cutting,shaping,welding,painting with two cots of synthetic enamal paint over a cot of zinc chromate primer etc as per actual requirement at site as required |
| 37 | OD502994/2025-2026:Labour charges for conveys 20 hp Summerasable motor, control panel and accessories, GI pipe, ISMB channel, C channel, materials for RCC work etc through land and narrow pathway of 100 mtrs (approx) , manually using physical effort as required. |
| 38 | OD502979/2025-2026:Charges for preparation of application and test report for KSEB connection Please Enable Macros to View BoQ information |