| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 2 | Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable(ISI marked) 1100 volts grade FRLS with multistranded copper conductor, drawn through concealed / surface in wall / roof/ceiling surface and its accessories on the surface etc including PVC rigid concealed conduit ,medium grade,of suitable size with all accessories such as bend, reducers, MS hooks including galvanised/pressed steel moduar terminal boxes of suitable size and white cover plate with frame as per relevant IS for mounting modular switches, sockets, fan regulators etc including continuous earth wire of size 1.5 Sqmm PVC FRLS stranded copper conductor unsheathed, insulated, stranded connected to common earth point dolly for following point 230 volts controlled by one switch complete all as specified and directed . |
| 3 | (a) One light point point controlled by one switch with cables 1.5 sq. mm size |
| 4 | (b) One fan/exhaust fan point controlled by one switch with cables 1.5 sq. mm size |
| 5 | (c) One 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5sq. mm size. |
| 6 | (d) One 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sq. mm size. |
| 7 | (e) One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables1.5 sq.mm. size. |
| 8 | (f) One power point with 2.5 sqmm copper conductor including 2.5 sqmm unsheathed copper continuity conductor connected to common earth dolly and controlled by one 15 Amp switch |
| 9 | (g) All as per items No 2 above for one point for (AC/geyser point ) with PVC insulated unsheathed FRLS cable, 1100 volt grade multy stranded copper conductor of size 4.00 sqmm (Nominal area ) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 4.0 sqmm (Nominal area ) cable common connected to earth dolly controlled by one switch complete all as specified and as directed by Engr-in-Charge. |
| 10 | M&L for Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable(ISI marked) 1100 volts grade FRLS with multistranded copper conductor, drawn through concealed / surface in wall / roof/ceiling surface and its accessories on the surface etc existing PVC/steel rigid conduit including galvanised/pressed steel moduar terminal boxes of suitable size and white cover plate with frame as per relevant IS for mounting modular switches, sockets, fan regulators etc including continuous earth wire of size 1.5 Sqmm PVC FRLS stranded copper conductor unsheathed, insulated, stranded connected to common earth point dolly for following point 230 volts controlled by one switch complete all as specified and directed . |
| 11 | (a) One light point point controlled by one switch with cables 1.5 sq. mm size |
| 12 | (b) One fan/exhaust fan point controlled by one switch with cables 1.5 sq. mm size |
| 13 | (c) One 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5sq. mm size. |
| 14 | (d) One 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sq. mm size. |
| 15 | (e) One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables1.5 sq.mm. size. |
| 16 | (f) One light point controlled by two 2-way switches, with cables 1.5 sq. mm size. |
| 17 | (g) One power point with 2.5 sqmm copper conductor including 2.5 sqmm unsheathed copper continuity conductor connected to common earth dolly and controlled by one 15 Amp switch |
| 18 | (h) All as per items No 2 above for one point for (AC/geyser point ) with PVC insulated unsheathed FRLS cable, 1100 volt grade multy stranded copper conductor of size 4.00 sqmm (Nominal area ) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 4.0 sqmm (Nominal area ) cable common connected to earth dolly controlled by one switch complete all as specified and as directed by Engr-in-Charge. |
| 19 | M&L switch piano flush button single pole one way 6 Amps 240 volts with polycarbonate body complete all as specified and directed. |
| 20 | M&L one Module switch 1 way 10 Amps 240 volts complete all as specified and directed. |
| 21 | M&L two way switch piano, flush button, single pole two way 6 amps 240 Volt with polycarbonate body complete all as specified and directed. |
| 22 | M&L Bell push switch piano flush button single pole one way 5 Amps 240 volts with polycarbonate body complete all as specified and directed. |
| 23 | Supply & Fixing Buzzer, Ding Dong AC. 230 volts, single pole. |
| 24 | Supply & Fixing switch piano flush type, single pole, one way 16 Amps complete all as specified and directed. |
| 25 | M&L one Module switch 1 way 16 Amps 240 volts complete all as specified and directed. |
| 26 | S&F multi socket outlet for 2 in 1, 3 pin, 6A, flush type complete all as specified and directed. |
| 27 | M&L Socket, 6A - 2/3 pin combined 2 module, type complete all as specified and directed. |
| 28 | M&L Moduler bell push 6A, 240 volts 1 Module complete all as specified and directed. |
| 29 | S&F socket outlet 2 in 1, 3 pin, 6 and 16 Amps , flush type, single pole, one way, 230Volts complete all as specified and directed. |
| 30 | M&L Modular socket 6A/16A , 240 volts 2/3 pin 2 Module complete all as specified and directed. |
| 31 | Supply & Fixingixing inreplacement of Ceiling rose, 3 phase/PVC/polycarbonate, isolated body for complete all as specified and directed. |
| 32 | Supply & Fixing inreplacement of Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings |
| 33 | S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. complete all as specified and directed. |
| 34 | M&L in replacement modular sheet cover plate with frame of size 8-12 module including necessary electrical connections as per existing point wiring complete all as specifed and directed. |
| 35 | M&L in replacement modular sheet cover plate with frame of size 6 module including necessary electrical connections as per existing point wiring complete all as specifed and directed. |
| 36 | M&L in replacement modular sheet cover plate with frame of size 3 module including necessary electrical connections as per existing point wiring complete all as specifed and directed. |
| 37 | M&L in replacement GI/pressed steel terminal switch board of size 8-12 module including necessary electrical connections as per existing point wiring complete all as specifed and directed. |
| 38 | M&L in replacement GI/pressed steel terminal switch board of size 4-6 module including necessary electrical connections as per existing point wiring complete all as specifed and directed. |
| 39 | M&L in replacement GI/pressed steel terminal switch board of size 1-3 module including necessary electrical connections as per existing point wiring complete all as specifed and directed. |
| 40 | Taking down old Sheet metal enclouser and supply and fix new sheet metal enclouser cubical type factory fabricated made out of 1.6 mm thick CRCA sheet with front side openable single door system powder coated painted to shade RAL 7032, PL Gasket, hinged single door, IP-55 mounting plate made out of 2mm thick CRCA sheet steel and earth bolts etc. of size 600x500x200mm all as speceified & directed by Engr-in- charge. Note :- Cost of any minor modification if required in fixing of the sheet metal enclouser as per site requirement and making good the disturbed surfaces matching with existing finish, will be deemed to be included in the cost of this item. |
| 41 | Disconnecting electric connections and taking down old unserviceable main switches/ DB’s sheet metal enclorsures 02 ways, 4 ways, 8 ways/ duly fitted with MCB’s/ cutouts 32 amps capacity including unserviceable wooden boards and making good the disturbed surface of the wall/ceiling. |
| 42 | Supply & Fixing MCB distribution box single door powder coated sheet metal encloser 240 volts SPN including 200 amps rated bus bar of the following type. |
| 43 | (a) 12 ways |
| 44 | (b) 08 ways |
| 45 | (c) 04 ways |
| 46 | Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of foour poles (TPN) and current carrying capacity 40 Amp to 100 Amp in the DB complete with connection testing and commissioning. |
| 47 | Supply and fixing SPN 40 TO 63 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 48 | Supply and fixing SPN 32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 49 | Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning. |
| 50 | S&F in replacement submain wiring with two runs of single core PVC FRLS unsheathed, insulated, copper cable of 2.5 Sqmm size, multi stranded, 1100 volts grade with PVC insulated,unsheathed FRLS copper wire 2.5 Sqmm for continous earth wire drawn into and including concealed PVC rigid conduit of suitable size including cutting chases in wall and making good all disturbed surfaces matching with existing surfaces complete all as specified and directed. Note :-Two runs of 2.5 Sqmm copper cable and one run of 2.5 sqmm copper wire earth continuty conductor in conduit with accessories shall be measured as one length) |
| 51 | S&F in replacement submain wiring with two runs of single core PVC FRLS unsheathed, insulated, copper cable of 4 Sqmm size, multi stranded, 1100 volts grade with PVC insulated,unsheathed FRLS copper wire 4 Sqmm for continous earth wire drawn into and including concealed PVC rigid conduit of suitable size including cutting chases in wall and making good all disturbed surfaces matching with existing surfaces complete all as specified and directed. Note :-Two runs of 4 Sqmm copper cable and one run of 4 sqmm copper wire earth continuty conductor in conduit with accessories shall be measured as one length) |
| 52 | Servicing of Exhaust fans of size upto 450 mm sweep including taking down from site, dismantling, cleaning, greasing/oiling of bush and bearings, replacement of set of split pins, cotter pins, blade screws of suitable size and ensuring fan blades screwed properly before refixing and making electric connection complete all as specified and directed. Note:- Rewinding and unserviceable parts other than specified in this item if any will be measured seperately. |
| 53 | M&L Taking down defective ceiling fan of any sweep and make after disconnecting electrically & mechanically and transporting to the work shop, opening, dismantling and taking out burnt winding wire by cutting, cleaning slots and re-winding of exhaust fan/wall mounted fan motor upto 450mm sweep with super enameled copper winding wire of gauge as per existing and approved from engr-in-charge before fitted including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading and brought back to site, re-fixing in position, complete all as specified and directed. |
| 54 | Taking down U/S earth plug and Supply & fix new metal clad 20 Amp 230 volts single pole and earth enclosure with two pin and earth plug with socket complete with one single pole MCB of 20 Amp 10 KA all as directed by Engineer-in-charge. |
| 55 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as per directed by Engr-in-Charge. |
| 56 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of uitable size from ceiling rose complete all as per directed by Engr-in-Charge. |
| 57 | Supply & fixing inreplacement of surfacce-mounted, round panel with die sact aluminium housing LED light 12 watt Jaquar cat part No LNVE02RO12SW or its equivalent. |
| 58 | S&F in replacement LED driver for 9W/10W/11W/15W/20W fitting as per existing model complete all as specified and directed. |
| 59 | Supply & Fixing building security light LED 25 watts including 25mm dia GI pipe with 120 degree bend with all accesories including fitting with point wiring in casing caping, with PVC box and switch PTS and all as specified and directed by Engr-in-Charge. |
| 60 | Taking down old U/S exhaust fan, deposited to MES store and supply and fixing metal/PVC frame exhaust fan of size 150/200mm sweep 1280 RPM, air delivery 520 CMH, power input 28 W single phase 240 Volts connected complete all as directed. |
| 61 | Taking down old U/S exhaust fan, deposited to MES store and supply and fixing metal frame exhaust fan of size 250mm sweep with louver 1280 RPM, air delivery 520 CMH, power input 28 W single phase 240 Volts connected complete all as directed. |
| 62 | Taking down old U/S exhaust fan, deposited to MES store and Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers connected complete all as directed. |
| 63 | Taking down old U/S exhaust fan, deposited to MES store and Supply and fix exhaust fan, steel body AC single Phase. 230V of size 380mm sweep with, blades, and frame and louvers connected complete all as directed. |
| 64 | Servicing of ceiling fans of capacity 1200/1400mm including taking down from site, dismantling, cleaning, greasing/oiling of bush and bearings, replacement of set of split pins, cotter pins, blade screws, canopy screws of suitable size and ensuring all blades screwed properly before refixing including replacement of PVC fan box round sheet as required on site and making electric connection and brought back to site, re-fixing in position, complete all as specified and directed.Note:- Rewinding and unserviceable parts other than specified in this item if any will be measured seperately. |
| 65 | M&L Taking down defective ceiling fan of any sweep and make after disconnecting electrically & mechanically and transporting to the work shop, opening, dismantling and taking out burnt winding wire by cutting, cleaning slots and re-winding of AC ceiling fan motor 1400/1200mm sweep any make with super enameled colour copper winding wire of gauge 35/36 SWG including, sleeve work, varnishing with 1st class insulation paper with threading complete all as specified and directed.Note:- Total weight of winding wire should not be less than 200gm Per fan Make of winding wire: RR/ BIC/ Devidyal/ Swastik or equivalent make as per command approved list. |
| 66 | Taking down defective BLDC ceiling fan of any sweep and make after disconnecting electrically & mechanically and transporting to the work shop, dismantling, examing & carrying out repair as required in all respect for smooth running and brought back to site, re-fixing in position, testing and comprising of the following:-(a) Servicing/overhauling of the ceiling fan by thoroughly cleaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing including applying one coat of super enameled varnish over the winding to improve the insulation value complete.(b) M&L for opening, cleaning, drying and re-winding or BLDC circuit plate the burnt/short circuited PCB or winding with same guage super enameled copper wire to maintain speed at load.(c) M&L for preparing the surface by scraping the existing paint, finishing and spray painting to ceiling fan with one coat of synthetic enamel paint . (d) Replacement of ball bearing suitable for ceiling fan of existing sweep & Make/Model |
| 67 | Supply and fixing down rod made of MS pipe medium grade 15mm dia of 300/600mm long duly drilled holes both ends and slot with hole in other end suitable for fixing of ceiling fan of any sweep/type and painting to down rod with spray painted two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 68 | Supply and fixing in replacement PVC canopy for ceiling fan of suitable size complete all as specified and directed. |
| 69 | Supply & replace ball bearing of make SKF/NBC/TATA – 6201 suitable for Ceiling/Exhaust Fan complete all as specified and directed by Engineer-In-Charge. |
| 70 | Supply & replace ball bearing of make SKF/NBC/TATA – 6202 suitable for Ceiling/Exhaust Fan complete all as specified and directed by Engineer-In-Charge. |
| 71 | Supply & replace ball bearing of make SKF/NBC/TATA – SSV3 suitable for Ceiling/Exhaust Fan complete all as specified and directed by Engineer-In-Charge. |
| 72 | Supply & fixing in replacement of gun metal bush of ceiling fan of size 1200/1400mm sweep as per existing size complete all as specified and directed. |
| 73 | Supply & replacement of Shaft of suitable size for any type and any sweep of Ceiling Fans complete all as directed by Engr-in-Charge. |
| 74 | Supply & fixing in replacement of old unserviceable shackle assy kit (rubber real -01, MS split clamp -02 Nos, nut, check nut, spring washer, bolt not less tha 6.0mm dia & split pin -02 Nos) suitable for ceiling fan 1200/1400mm sweep complete all as specified and directed. |
| 75 | Supply & fixing in replacement of ceiling fan blades made of MS sheet duly powder coated of thickness not less than 1.0mm suitable for 1400/1200mm sweep ceiling fan complete all as specified and directed. |
| 76 | Supply & fixing inreplacement of down rod of of length 12\\" to 18\\" as existing for ceiling fan 1200/1400 sqmm. |
| 77 | M&L removing old paint by scraping with sand paper including washing and filling cavaties with filler and applying two coats of painting with existing colour to ceiling fan 1200-1400mm sweep at site with heat resistant synthetic enamel paint by spray painting on the ceiling fans complete all as specified and directed. |
| 78 | M&L removing old paint by scraping with sand paper including washing and filling cavaties with filler and applying two coats of painting with existing colour to Exhuast fan upto 450mm sweep alongwith connected part at site with heat resistant synthetic enamel paint by spray painting incl on the Exhuast fan complete all as specified and directed. |
| 79 | Supply and fixing in replacement cable PVC insulated and overall sheathed with flexible copper conductor 2 core of size 0.5sqmm complete all as specified and directed. |
| 80 | Supply & fixing in replacement of capacitor holder for ceiling fan 1200/1400 mm sweep. |
| 81 | Supply & fixing in replacement of capacitor AC 2.5 mfd modified with copper wire terminal incl PVC clamp complete all as specified and directed. |
| 82 | Supply and fixing in replacement of syphon assembly of 6 hole/09 holes as per site requirement made out of brass of 25 ltr capacity (ISI marked) including necessary studs screws and rubber gasket/washers complete all as specified and directed. |
| 83 | Supply and fixing in replacement of thermostat switch (ISI marked) suitable for geyser 25 ltr to 50 ltr, AC 230 volt adjustable range from 0-90 degree Celsius as per exisiting size, make and shape complete all as specified and directed. |
| 84 | Supply and fixing in replacement of heating element titanium coated of rating 1.5/2 KW suitable for geyser any type and make as per existing and site requirement incl gasket washer (ISI marked) geyser element AC 230 volt complete all as specified and directed. |
| 85 | S&F in replacement of 15 Amp plug top, 3 pin complete all as specified and directed. |
| 86 | Dismantling/removal carefully and fixing at the same place exhaust fan of any size and any shape with necessary iron frmae, nut, bolt including grounting, inserting fasters as suitable size including inserting of wood frame all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |