| 1 | Taking down defective 25/36/40/45/60/90 Watt LED light fitting/SV/MH fittings, street light fitting/ flood light fittings mounted on pole/bldg on bracket disconnecting, testing all components, dismantling of defective components such as choke, igniters, holders, capacitors, and providing PVC cable for wiring lamps, including cleaning of cover, connection with supply and testing the street light fitting after fixing new components and including trimming of branch if obstacle for lights to illuminate the area and then mounting to its original position and making the fitting functional complete all as specified and directed. |
| 2 | Supply only LED security light driver ISI approved company made as suitable for LED fittings of cap upto 25-60 watts any type and make, complete all as specified and directed. |
| 3 | Supply only LED security light connector ISI approved company made as suitable for LED fittings of cap upto 60-100 watts any type and make, complete all as specified and directed. |
| 4 | Supply only LED security light Surge protective Device (SPD) ISI approved company made as suitable for LED fittings any type and make, complete all as specified and directed. |
| 5 | Supply only LED security light driver ISI approved company made as suitable for LED fittings of cap upto 110 to 150 watts any type and make, complete all as specified and directed. |
| 6 | Supply and fixing as in repair of 90W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance.LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed. |
| 7 | Supply and fixing as in repair of 60W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance.LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed. |
| 8 | Supply and fixing as in repair of 45W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance.LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed. |
| 9 | Replacement of old UNSV / damaged flood light fitting any type and S & F LED Flood Light luminaire in pressure die-cast aluminium housing with IP66 protection 30 watts, 230 volts, 50 Hz, area lighting including 30 watts LEDs and driver complete all as specified and directed. |
| 10 | Replacement of old UNSV / damaged street light fitting any type and S & F LED Flood Light luminaire in pressure die-cast aluminium housing with IP66 protection 100 watts, 230 volts, 50 Hz, area lighting including 100 watts LEDs and driver complete all as specified and directed. |
| 11 | Replacement of old UNSV / damaged post-top and S&F Circular LED 40W post-top offering excellent uniform illumination and aesthetics in one go. Made up of pressure Die Cast aluminium body and opal PC cover. IP 66 and IK 07 rating ensures it stands tall amid varied environmental conditions includeed GI pipe 75 MM 4 feet long complete all as specified and directed. |
| 12 | Replacement of old UNSV / damaged post-top and S&F New generation IP 65 LED 35W post-top, energy saving, environmental friendly, long life aesthetically designed with good indirect symmetrical light distribution, die-cast aluminium landscape luminaire with high power COB LED as light source. includeed GI pipe 75 MM 4 feet long complete all as specified and directed. |
| 13 | S&Fin replacement MUSHROOM NXT 10W Bollard light fitting New generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape IP 65 luminaire for diffused lighting with high power LED as light source. with PCC 1:3:6 and grouting the bolts for fixing light fitting & connecting complete all as specified and directed. |
| 14 | M & L in replacement DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installation including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/16 Sqmm 2/4 core and fixed to the PSC/Steel Poles by means of suitable size of clamps with nut ,bolts and including provn for fixing 01 no of single pole MCBs 6-32 amps,10KA and MCB TPN 6-32 amps, 10 KA, ‘B’ series = 01 No inside the box complete all as specified and directed. |
| 15 | M & L in replacemant for Street Light Fitting Bracket made out from GI Pipe 40/50 mm bore (dia), medium grade 1.50 metre long, bent to required shape and fixing to Poles with and including suitable size Mild Steel Clamp set made out of 32 x 6 mm thick for fixing to PCC Pole with bolt, nuts, washers as requiredduly painted with Two Coats of Aluminum Paint over a coat of Red Oxide Zinc Chrome Primer including taking down old unserviceable bracket, comlete all as specified and as directed. Note : Cost of fabrication of MS clamp, Nuts, Bolts and painting is deemd to be included in the quoted Unit Rate complete all as specified and directed. |
| 16 | S & F Replacement for Contactor suitable for Street Light Time Switch 4 Pole, 32/40 Amps, 415 Volt, including taking down old unserviceable Contactor, complete all as specified and as directed. |
| 17 | S & F Replacement street light timer with Astonomical switch (suitable for Ladakh area) Time Switches 240 Volt, 50 Hz, One module, and connecting with contactor including taking down old unserviceable one complete all as specified and as directed. |
| 18 | Supply and laying in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated PVC sheathed, armoured heavy duty electric cable , with aluminium conductor of size 25 Sqmm x 4 core complete all as specified and directed. Note:- Excavation and earth work, sand cushioning, brick cover and protection pipe etc. shall be measured and paid for separately. |
| 19 | Description all as per srl item No 18 here-in-before, but cable of size 16 Sqmm x 4 core complete all as specified and directed. |
| 20 | Description all as per srl item No 18 here-in-before, but cable of size 16 Sqmm x 2 core complete all as specified and directed. |
| 21 | Description all as per srl item No 18 here-in-before, but cable of size 10 Sqmm x 2 core complete all as specified and directed. |
| 22 | Supply, jointing and testing straight through, heat shrinkable, jointing kit suitable for PVC/ XLPE insulated armoured heavy duty aluminium conductor 1100 volt grade of size 10/16 Sqmm, 4 core including taking out faulty portion of cable in any situation/ position complete all as specified and as directed. |
| 23 | All as per srl item No 22 here in before but for cable of size 25-50Sqmm, 3.5 core complete all as specified and as directed. |
| 24 | All as per srl item No 22 but for cable of size 70-120 Sqmm, 3.5 core complete all as specified and as directed. |
| 25 | M&L for locating the fault in underground electrical power cable of any length & any type of 1100 volt grade LT cables, by arranging fault locating Machine & pin point the fault, cutting the cable at fault to fixing the joint including testing of the cable after locating fault and jointing cable including excavation and earth work in any type of soil complete all as specified and as directed. Note:- (i) Jointing of cable shall be measured and paid separately under respective item of this Schedule. (ii) If fault is not rectified within 24 hours after receiving Message, the contractor shall be charged penalty for Rs 500/- per hour per complaint and shall be deducted from next payment due to contractor. |
| 26 | Excavating in trenches in Hard/dense soil, n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n.exc 1.5 m in depth and getting out complete all as specified and directed. |
| 27 | Removing excavated material (soil) n.exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed. |
| 28 | Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed. |
| 29 | Supply and fix Double wall corrugated (DWC) outer pipe 40mm and inner dia 32 mm fix complete to Wall, Poles etc with suitable clamp for protection of cable complete all as specified and directed. |
| 30 | Supply and fixing in replacement GI tubing light grade 40 mm bore cut to size and fixed along the pole for cable protection including clamp 02 Nos of size 25x4 mm, nut bolts , washers etc complete all as specified and directed. |
| 31 | M&L for Painting of single LT steel tubular, structure including. cleaning and scrapping the old surface and then applying two coat of aluminium synthetic enamel paint over a coat of red oxide primer on all steel structure mounted on pole viz. Cross Arms , Clamps, bolts, nuts, brackets etc. and including painting of pole/ structure ith two coat of synthetic black & yellow enamel paint strip 300 mm wide alternative from bottom to upward of LT pole up to height of 1.5 mtr above the embedded portion of GL and writing pole number balance portion of pole shall be painted with two coats of Aluminium enamel paint over a coat of red oxide primer, complete the following as specified and directed :-Notes: - (i) Pole will be cleaned with steel brush to remove old unserviceable paint or scrapped complete surface.(ii) All poles will be numbered all as directed at site.(iii) If painting of poles not properly and not satisfied by JE/Engr-in-charge shall not be paid to contractor or otherwise repaint without extra cost. |
| 32 | M&L Horizontal boring of holes under road /pavement /hard standing or any other situation by manual mean and providing 50mm bore, medium grade GI pipe for passing cables etc and making good both the ends complete all as specified and as directed. |
| 33 | M & L for prunning of tree branches of any sizes and dia, not less than 2 Mtr around the LT OH line which obstructing the power supply/ maintenance of electric supply as well as illumination in area including repair of damage broken ACSR conductor, GI wire and jumpers and disposed exc 50 mtr away clearing area and testing of line, complete all as specified and directed.Note : (i) Span length is aproximate 40 to 50m.(ii) Rate quoted are inclusive of repair to damage work in item. |
| 34 | Supply only in repair Tape 25mmx50 mtrs complete all as specified and directed. |
| 35 | S&F in replacement of LT out door fedder piller with built in 63 MCCB, 200 Amps, aluminum bus bar, RYB indicators, Multi function meter digital type complete all as specified and directed. |
| 36 | Supply and fix in replacement of 4 Pole MCCB 400 Amp, 50 Hz, 415 V with Adjustable Thermal & Adjustable Magnetic and rupturing capacity 36 KA complete all as specified and directed. |
| 37 | Supply and fix in replacement of 4 Pole MCCB 200 Amp, 50 Hz, 415 V with Adjustable Thermal & Adjustable Magnetice and rupturing capacity 36 KA complete all as specified and directed. |
| 38 | Supply and fix in replacement of 4 Pole MCCB 125 Amp, 50 Hz, 415 V with Adjustable Thermal & Adjustable Magnetic and rupturing capacity 16 KA complete all as specified and directed. |
| 39 | Supply and fix in replacement of 4 Pole MCCB 100 Amp, 50 Hz, 415 V with Adjustable Thermal & Adjustable Magneticand rupturing capacity 16 KA complete all as specified and directed. |
| 40 | Supply and fixing in replacement of change over switch 4 pole 415 volts 200 Amp in conforming to IS with front operated handle complete with fixing in existing LT Panel complete all as specified and directed. |
| 41 | Supply and fixing in replacement of change over switch 4 pole 415 volts 400 Amp in conforming to IS with front operated handle complete with fixing in existing LT Panel complete all as specified and directed. |
| 42 | Supply and fixing in replacement of open execution change over switch 4 pole 415 volts 100 Amp in sheet steel enclosure conforming to IS with side operated handle complete with fixing on wall and angle iron bracket of size 40x40x6mm thick as per size requirement or complete all as specified and directed. |
| 43 | Supply and fixing in replacement of open execution change over switch 4 pole 415 volts 200 Amp in sheet steel enclosure conforming to IS with side operated handle complete with fixing on wall and angle iron bracket of size 40x40x6mm thick as per size requirement or complete all as specified and directed. |
| 44 | Supply and fixing Acrylic channel LED glow sign board with Power supply arrangement for 12\\" height letter, (8 letters) including fabrication and connected works etc. complete all as specified and directed. |
| 45 | Supply and fixing Acrylic channel LED glow sign board with Power supply arrangement for 12\\" height letter, (27 letters) including fabrication and connected works etc. complete all as specified and directed. |
| 46 | M & L for Danger Notice Plate of 1.6 mm thick Mild Steel Sheet, vitreous enamelled white, with Letters, Figures and Conventional Skull and Bones in Signal Red colour and fixed with MS Clamps Bolt and Nuts of approved size, for LT 20 x 15 Cm size including dismantling unserviceable one, complete all as specified and as directed . |
| 47 | S&F LED outdoor stip light IP-65, 60 LEDs per meter, 14.4 watt in Tiranga light along with strip connector, including end cap complete all as specified and directed. |
| 48 | Supply and fixing LED Solar street light fitting 16 Watt including galvanised steel pole in built lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and directed. |
| 49 | M& L for GI tubing medium grade, 40mm 1.5 Mtr long for Post top,bollard , duly black painted after primer coating etc including earth work for erraction of fitting completed all as specified and directed. |
| 50 | M&L for plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate in foundation of stay assembly etc including necessary form work, complete all as specified and directed. |
| 51 | M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundation of stay assembly etc including necessary form work, complete all as specified and directed. Please Enable Macros to View BoQ information |
| 52 | M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundation of stay assembly etc including necessary form work, complete all as specified and directed. Please Enable Macros to View BoQ information |